Research Commons

Multiple frequency range imaging to remove measurement ambiguity

Research Commons

Show simple item record

dc.contributor.author Payne, Andrew D.
dc.contributor.author Jongenelen, Adrian P.P.
dc.contributor.author Dorrington, Adrian A.
dc.contributor.author Cree, Michael J.
dc.contributor.author Carnegie, Dale A.
dc.date.accessioned 2010-06-22T23:49:13Z
dc.date.available 2010-06-22T23:49:13Z
dc.date.issued 2009
dc.identifier.citation Payne, A.D., Jongenelen, A.P.P., Dorrington, A.A., Cree, M.J. & Carnegie, D.A. (2009). Multiple frequency range imaging to remove measurement ambiguity. In Proceedings of at 9th Conference on Optical 3-D Measurement Techniques, July 1-3, 2009, Vienna, Austria(pp. 139-148). Vienna, Austria: Vienna University of Technology. en_NZ
dc.identifier.uri http://hdl.handle.net/10289/4032
dc.description.abstract Range imaging systems use a specialised sensor to capture an image where object distance (range) is measured for every pixel using time-of-flight. The scene is illuminated with an amplitude modulated light source, and the phase of the modulation envelope of the reflected light is measured to determine flight time, hence object distance for each pixel. As the modulation waveform is cyclic, an ambiguity problem exists if the phase shift exceeds 2π radians. To overcome this problem we demonstrate a method that superposes two different modulation frequencies within a single capture. This technique reduces the associated overhead compared with performing two sequential measurements, allowing the system to retain high range measurement precision at rapid acquisition rates. A method is also provided to avoid interference from aliased harmonics during sampling, which otherwise contaminate the resulting range measurement. Experimental results show the potential of the multiple frequency approach; producing high measurement precision while avoiding ambiguity. The results also demonstrate the limitation of this technique, where large errors can be introduced through a combination of a low signal to noise ratio and suboptimal selection of system parameters. en_NZ
dc.format.mimetype application/pdf
dc.language.iso en
dc.relation.uri http://info.tuwien.ac.at/ingeo/optical3d/ en_NZ
dc.rights This article has been published in Proceedings of at 9th Conference on Optical 3-D Measurement Techniques, July 1-3, 2009, Vienna, Austria. en_NZ
dc.subject range imaging system en_NZ
dc.title Multiple frequency range imaging to remove measurement ambiguity en_NZ
dc.type Conference Contribution en_NZ


Full-text options:

This item appears in the following Collection(s)

Show simple item record

Search Research Commons


Advanced Search

Browse

Theses

About Research Commons

My Account

Usage Statistics

Share

  • Bookmark and Share