Optimisation of non-isothermal utilities using the Unified Total Site Heat Integration method

dc.contributor.authorTarighaleslami, Amir Hosseinen_NZ
dc.contributor.authorWalmsley, Timothy Gordonen_NZ
dc.contributor.authorAtkins, Martin Johnen_NZ
dc.contributor.authorWalmsley, Michael R.W.en_NZ
dc.contributor.authorNeale, James R.en_NZ
dc.date.accessioned2017-01-26T01:29:55Z
dc.date.available2016en_NZ
dc.date.available2017-01-26T01:29:55Z
dc.date.issued2016en_NZ
dc.description.abstractTotal Site Heat Integration is an effective method for design of large scale utility systems that serve large chemical processes, such as refineries, petrochemicals or even lower temperature chemical and process plants. Total Site Heat Integration of different chemical plants might confront batch, semi-continuous or continuous plants which are clustered into one large site. Excess heat produced from one plant could be transferred to other plants using an intermediate fluid. In this paper, Total Site optimisation of targeting utility generation and consumption for lower temperature processes, which mainly use non-isothermal utilities, is presented. The utility temperature selection optimisation applies to the recently developed Unified Total Site Heat Integration Targeting (UTST) method. The new method shows that, for low temperature processes where non-isothermal utilities are used, the supply and target temperatures of a utility is an important constraint, while for higher temperature processes, where isothermal utilities are applied, no significant change in targets from conventional Total Site are obtained. New heuristics based on UTST method with respect to non-isothermal utility temperature selection are proposed. A Kraft Pulp Mill case study has been investigated in this research, using optimised non isothermal utilities, showing a 3.6 MW increase in heat recovery, 0.87 MW decrease in shaft work generation, and $ 330,000 /y utility cost saving in the system applying the new UTST method compared to the conventional Total Site method.
dc.format.mimetypeapplication/pdf
dc.identifier.citationTarighaleslami, A. H., Walmsley, T. G., Atkins, M. J., Walmsley, M. R. W., & Neale, J. R. (2016). Optimisation of non-isothermal utilities using the Unified Total Site Heat Integration method. Chemical Engineering Transactions, 52, 457–462. https://doi.org/10.3303/CET1652077en
dc.identifier.doi10.3303/CET1652077en_NZ
dc.identifier.issn1974-9791en_NZ
dc.identifier.urihttps://hdl.handle.net/10289/10861
dc.language.isoen
dc.publisherAIDICen_NZ
dc.relation.isPartOfChemical Engineering Transactionsen_NZ
dc.rightsCopyright © 2016, AIDIC Servizi S.r.l.. Used with permission.
dc.titleOptimisation of non-isothermal utilities using the Unified Total Site Heat Integration methoden_NZ
dc.typeJournal Article
pubs.begin-page457
pubs.elements-id145032
pubs.end-page462
pubs.organisational-group/Waikato
pubs.organisational-group/Waikato/FSEN
pubs.organisational-group/Waikato/FSEN/School of Science
pubs.organisational-group/Waikato/OOVC
pubs.organisational-group/Waikato/OOVC/AVCS
pubs.organisational-group/Waikato/Staff
pubs.publisher-urlhttp://www.aidic.it/cet/16/52/programma.htmlen_NZ
pubs.volume52en_NZ
uow.verification.statusverified
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2016 tarighaleslami walmsley atkins walmsley neale Chemical Engineering Transactions.pdf
Size:
1.17 MB
Format:
Adobe Portable Document Format
Description:
Published version
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Research Commons Deposit Agreement 2016.txt
Size:
263 B
Format:
Unknown data format
Description: