dc.identifier.citationUche, C.Z., Round, W.H. & Cree, M.J. (2011). A Monte Carlo evaluation of three Compton camera absorbers. Australasian Physical & Engineering Science in Medicine, published online 28 June 2011.en_NZ
dc.identifier.urihttps://hdl.handle.net/10289/5635
dc.description.abstractWe present a quantitative study on the performance of cadmium zinc telluride (CZT), thallium-doped sodium iodide (NaI(Tl)) and germanium (Ge) detectors as potential Compton camera absorbers. The GEANT4 toolkit was used to model the performance of these materials over the nuclear medicine energy range. CZT and Ge demonstrate the highest and lowest efficiencies respectively. Although the best spatial resolution was attained for Ge, its lowest ratio of single photoelectric to multiple interactions suggests that it is most prone to inter-pixel cross-talk. In contrast, CZT, which demonstrates the least positioning error due to multiple interactions, has a comparable spatial resolution with Ge. Therefore, we modelled a Compton camera system based on silicon (Si) and CZT as the scatterer and absorber respectively. The effects of the detector parameters of our proposed system on image resolution were evaluated and our results show good agreement with previous studies. Interestingly, spatial resolution which accounted for the least image degradation at 140.5 keV became the dominant degrading factor at 511 keV, indicating that the absorber parameters play some key roles at higher energies. The results of this study have validated the predictions by An et al. which state that the use of a higher energy gamma source together with reduction of the absorber segmentation to sub-millimetre could achieve the image resolution of 5 mm required in medical imaging.en_NZ
dc.language.isoen
dc.publisherSpringeren_NZ
dc.relation.urihttp://www.springerlink.com/content/x2k4766x7457j582/en_NZ
dc.subjectCompton cameraen_NZ
dc.subjectabsorberen_NZ
dc.subjectGEANT4en_NZ
dc.subjectdetector parametersen_NZ
dc.subjectgamma raysen_NZ
dc.titleA Monte Carlo evaluation of three Compton camera absorbersen_NZ
dc.typeJournal Articleen_NZ
dc.identifier.doi10.1007/s13246-011-0085-1en_NZ
dc.relation.isPartOfAustralian Physical & Engineering Sciences in Medicineen_NZ
pubs.begin-page351en_NZ
pubs.elements-id36584
pubs.end-page360en_NZ
pubs.issue3en_NZ
pubs.volume34en_NZ


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record