Research Commons
      • Browse 
        • Communities & Collections
        • Titles
        • Authors
        • By Issue Date
        • Subjects
        • Types
        • Series
      • Help 
        • About
        • Collection Policy
        • OA Mandate Guidelines
        • Guidelines FAQ
        • Contact Us
      • My Account 
        • Sign In
        • Register
      View Item 
      •   Research Commons
      • University of Waikato Research
      • Science and Engineering
      • Science and Engineering Papers
      • View Item
      •   Research Commons
      • University of Waikato Research
      • Science and Engineering
      • Science and Engineering Papers
      • View Item
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Evaluation of two Compton camera models for scintimammography

      Uche, Chibueze Zimuzo; Round, W. Howell; Cree, Michael J.
      DOI
       10.1016/j.nima.2011.09.058
      Link
       www.sciencedirect.com
      Find in your library  
      Citation
      Export citation
      Uche, C.Z., Round, W.H. & Cree, M.J. (2011). Evaluation of two Compton camera models for scintimammography. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, available online 8 October 2011.
      Permanent Research Commons link: https://hdl.handle.net/10289/5869
      Abstract
      We study the performance of a Si/LaBr3:Ce Compton camera model for scintimammography, and compare it with a Si/NaI(Tl) model of similar geometry. The GEANT4 simulation toolkit was used to study the behaviour of the cameras at 511 keV. Certain simulation steps, such as the modelling of radionuclide decay times, scintillation photon transport and interactions with photomultipliers, as well as detector dead time corrections were included to make the modelling of the cameras more realistic than previous studies. The Si/LaBr3:Ce Compton camera shows superior efficiency of 2.0×10⁻³ and resolution of 5.3 mm over the Si/NaI(Tl) Compton camera model which has the efficiency of 1.6×10⁻³ and resolution of 6.9 mm at a source-to-scatterer distance of interest, 2.5 cm. A similar result sequence is obtained for two breast tumours of 5 mm diameter embedded in the medial region of an average-size breast phantom of thickness 5 cm. Notably, the signal-to-noise ratios (SNR) obtained for the Si/LaBr3:Ce camera are 9.7 and 3.4 for tumour/background radiation uptakes of 10:1 and 6:1, whereas 6.8 and 2.4 were obtained for the Si/NaI(Tl) camera model for the same tumour/background radiation uptakes respectively. It is therefore envisioned that with lower cost, LaBr3:Ce could replace NaI(Tl) as the Compton camera absorber.
      Date
      2011
      Type
      Journal Article
      Publisher
      Elsevier
      Collections
      • Science and Engineering Papers [3122]
      Show full item record  

      Usage

       
       
       

      Usage Statistics

      For this itemFor all of Research Commons

      The University of Waikato - Te Whare Wānanga o WaikatoFeedback and RequestsCopyright and Legal Statement