Show simple item record  

dc.contributor.authorWalmsley, Timothy Gordon
dc.contributor.authorWalmsley, Michael R.W.
dc.contributor.authorAtkins, Martin John
dc.contributor.authorFodor, Zsófia
dc.contributor.authorNeale, James R.
dc.coverage.spatialPrague, CZECH REPUBLICen_NZ
dc.date.accessioned2013-02-26T02:20:18Z
dc.date.available2013-02-26T02:20:18Z
dc.date.issued2012
dc.identifier.citationWalmsley, T., Walmsley, M.R.W., Atkins, M.J., Fodor, Z. & Neale, J.R. (2012). Chemical Engineering Transactions, 29, 403-408.en_NZ
dc.identifier.isbn9788895608204
dc.identifier.issn1974-9791
dc.identifier.urihttps://hdl.handle.net/10289/7259
dc.description.abstractA typical drying process that has liquid and gas discharge streams has been analysed and the impact of selecting various combinations of soft temperatures on heat recovery, utility targets, area targets, capital cost and total cost is reported. The method is based on the plus-minus principle and traditional pinch analysis methods for utility, area and capital cost targeting with the modification of using a ΔT contribution. Results show that there is significant benefit from optimising discharge temperatures for total cost. To achieve minimum energy consumption and total cost, heat recovery from the dryer exhaust air is necessary. Heat recovery from liquid heat sources is shown to be preferable over gas streams due to a higher film coefficient resulting in less heat exchanger area and capital cost. There is also value in making process modifications, such as combining streams or removing small streams to be solely heated by utility, to reduce the number of network heat exchangers. For the best case, the discharge temperatures of the leaving streams are 18.0 °C for water condensate (liquid stream) and 52.4 °C for the exhaust air (gas stream).en_NZ
dc.format.mimetypeapplication/pdf
dc.language.isoen
dc.publisherAIDIC Servizi S.r.len_NZ
dc.relation.urihttp://www.aidic.it/cet/index.htmlen_NZ
dc.rights© 2012, AIDIC Servizi S.r.l. Used with permission.en_NZ
dc.subjectheat recoveryen_NZ
dc.subjectwateren_NZ
dc.titleOptimal waste stream discharge temperature selection for dryer operations using thermo-economic assessmenten_NZ
dc.typeJournal Articleen_NZ
dc.identifier.doi10.3303/CET1229068en_NZ
dc.relation.isPartOfChemical Engineering Transactionsen_NZ
pubs.begin-page403en_NZ
pubs.elements-id37977
pubs.end-page408en_NZ
pubs.volume29en_NZ


Files in this item

This item appears in the following Collection(s)

Show simple item record