Wilson, Marcus T.2024-01-222024-01-222023https://hdl.handle.net/10289/16378• We have modelled Calcium-dependent plasticity with a Neural Field scheme • Developed the approach further to modelling MEPs • Modelling can reproduce MEP ranges from submillivolt to ~10 mV • Modelling can reproduce both potentiation and depression following cTBS and iTBS • In terms of variability of MEPs, the following are important: • TMS-to-e coupling strength (parameter μ) • Excitatory-to-excitatory coupling strength wee • Number of pulses / time since stimulation • Include reporting of actual thresholds when %RMT is usedapplication/pdfen© 2023 The Author.ModelingTranscranial Magnetic StimulationCalcium modeling and TMS variabilityConference Contribution