10-year survival comparison of two cemented implants in primary total hip arthroplasty for osteoarthritis: A New Zealand regional study

dc.contributor.authorPearce, Amy
dc.contributor.authorJoshi, Chaitanya
dc.contributor.authorChan, Georgina
dc.contributor.authorLamberton, Tony
dc.contributor.authorMacLean, Simon
dc.contributor.authorVane, Andrew
dc.contributor.authorHébert-Losier, Kim
dc.coverage.spatialGermany
dc.date.accessioned2026-04-22T04:29:43Z
dc.date.available2026-04-22T04:29:43Z
dc.date.issued2025
dc.description.abstractIntroduction Compare 10-year survival of the cemented highly crosslinked polyethylene Exeter® Rimfit™ (Rimfit) Cup and its predecessor, the ultra-high molecular weight polyethylene Exeter® Contemporary Flanged Cup™ (ECF), both with an Exeter® V40™ stem, in primary total hip arthroplasty (THA) for osteoarthritis in the Bay of Plenty region of NZ. Method We extracted national registry data for THA surgeries in the region between 1 January 2003 and 30 June 2023 and report the 10-year survival and reasons for revision of the two fully cemented implants (n = 495). We compared standard Kaplan-Meier estimates using the log-rank test. Cox proportional hazard models investigated the potential influence of six patient variables on the survival of each implant: sex, age, body mass index (BMI), ethnicity, American Society of Anesthesiologists (ASA) rating, and funding source (public/private). Results No statistically significant difference in 10-year survival rate between the implants (p = 0.334) (ECF 95.6% [93.4, 97.9], Rimfit 97.0% [95.9, 98.2]) or statistically significant difference in revision reasons between the implants (p = 0.09) was noted. Cox regression revealed no statistically significant influence of any of the six patient variables on the 10-year survival of the ECF (p = 0.584) or Rimfit (p = 0.611). Conclusion Both implants exceeded 95% survival at 10-years, which is favourable compared to the corresponding 94.8% national survivorship of cemented implants in NZ. There is no statistically significant difference in the 10-year survival rate or reasons for revision of the two cemented implants compared in this region. The Rimfit appears a suitable alternative to the ECF, from a survival and revision perspective.
dc.identifier.citationPearce, A., Joshi, C., Chan, G., Lamberton, T., MacLean, S., Vane, A., & Hébert-Losier, K. (2025). 10-year survival comparison of two cemented implants in primary total hip arthroplasty for osteoarthritis: A New Zealand regional study. Archives of Orthopaedic and Trauma Surgery, 145, Article 495. https://doi.org/10.1007/s00402-025-06092-4
dc.identifier.doi10.1007/s00402-025-06092-4
dc.identifier.eissn1434-3916
dc.identifier.issn0936-8051
dc.identifier.urihttps://hdl.handle.net/10289/18227
dc.languageEnglish
dc.language.isoen
dc.publisherSpringer
dc.relation.isPartOfArchives of Orthopaedic and Trauma Surgery
dc.rightsLicence for published version: Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjecttotal hip replacement
dc.subjectfixation
dc.subjectrevision
dc.subjecthybrid
dc.subjectPolyethylene
dc.subjectFixation
dc.subjectHybrid
dc.subjectPolyethylene
dc.subjectRevision
dc.subjectTotal hip replacement
dc.subject.anzsrc202032 Biomedical and Clinical Sciences
dc.subject.anzsrc20203202 Clinical Sciences
dc.subject.anzsrc20203202 Clinical sciences
dc.title10-year survival comparison of two cemented implants in primary total hip arthroplasty for osteoarthritis: A New Zealand regional study
dc.typeJournal Article
dspace.entity.typePublicationen

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Pearce (2025) ten year survival.pdf
Size:
1.04 MB
Format:
Adobe Portable Document Format
Description:
Published version

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
82 B
Format:
Plain Text
Description: