<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

University of Waikato Research

Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288

Browse

Search Results

Now showing 1 - 7 of 7
  • Item type:Publication,
    Effect of flow distribution on the photovoltaic performance of a building integrated photovoltaic/thermal (BIPV/T) collector
    2012, Elsevier
    The phenomenon of non-uniform flow distribution and its influence on thermal performance within a traditional solar thermal collector is well known. Its effect on the photovoltaic conversion of a hybrid photovoltaic/thermal (PV/T) collector however has received little attention. In this study an investigation has been carried out to determine what effect flow distribution will have on the photovoltaic yield of a BIPV/T collector of various size. A three step numerical analysis was conducted to model flow distribution, temperature variation, and photovoltaic yield for a PV/T collector of various design (manifold sizes), geometric shape (aspect ratio), and operating characteristics (mass flow rate and flow direction in manifolds) in order to vary flow uniformity within the collector. The results revealed that flow distribution within the collector will have a significant influence on the photovoltaic performance of a hybrid PV/T collector. For the scenario where flow distribution was most uniform, photovoltaic performance was improved by over 9% in comparison to a traditional photovoltaic (PV) collector operating under the same conditions. For poor flow however, performance was only improved by approximately 2%. Parameters found to influence flow distribution include the manifold to riser pipe ratio where a ratio of 4:1 was found to be ideal and that increasing to a 6:1 ratio offered negligible improvement. Additionally it was found that array geometry (characterised by its aspect ratio in this study) plays an important role on both flow distribution and photovoltaic yield. This study has identified that the optimal mass flow rate is dependent on the shape or aspect ratio of the array.
  • Item type:Publication,
    Numerical calculation of series and shunt resistance of a photovoltaic cell using the Lambert W-function: Experimental evaluation
    2013, Elsevier
    The values of series and shunt resistances play an important role in the modelling behaviour of a photovoltaic cell. The authors proposed in earlier work a new method to determine these values numerically at maximum power point using the Newton-Raphson method and equations based on the Lambert W-function. Here, an experimental investigation has been carried out to further validate this method and observe its behaviour over the entire current voltage curve. Current voltage curves from a single multi-crystalline cell were obtained under outdoor testing in Hamilton, New Zealand under three levels of illumination (800, 900, and 1000 W/m(2)). In addition to the method of Ghani and Duke (2011), two other methods were also used to calculate series and shunt resistances based on the parameters extracted from the experimental data. A comparative study of each methods output current vector using a root mean square error analysis revealed that greatest accuracy was achieved with the proposed approach.
  • Item type:Publication,
    Numerical calculation of series and shunt resistances and diode quality factor of a photovoltaic cell using the Lambert W-function
    2013, Elsevier
    A number of methods currently exist to determine the modeling parameters of a solar cell. The authors presented in earlier a work a method to numerically determine the values of series and shunt resistance using the Lambert W-function at maximum power point primarily using data provided by the manufacturer. This method however assumes the diode constant value is known. An experimental investigation revealed that by setting the diode constant to unity as suggested in other work, a growing disparity between model output and experimental values would arise away from the maximum power point. To address this issue, a modification is proposed to the method of Ghani and Duke (2011) which permits the calculation of the diode constant and the corresponding values of series and shunt resistances. The method was experimentally validated by collecting the current-voltage characteristics of a multi-crystalline cell exposed to 800, 900, and 1000 W/m² of outdoor illumination in Hamilton, New Zealand. A comparative analysis of the model generated data using parameters found by the proposed method and two additional methods against experimental data revealed a significant reduction in the root mean square error over the entire current vector was obtained using the proposed method. The method is simple to apply and can be carried out using data provided the manufacturer.
  • Item type:Publication,
    Estimation of photovoltaic conversion efficiency of a building integrated photovoltaic/thermal (BIPV/T) collector array using an artificial neural network
    2012, Elsevier
    Earlier studies have shown that the thermal efficiency of a solar thermal collector is influenced by the quality of coolant flow distribution within the array. The quality of flow distribution within a header/riser type fluid network is influenced by a number of parameters including the coolant mass flow rate, the direction of flow in the manifolds, and most importantly the geometry of the array. As a building integrated photovoltaic thermal (BIPVT) collector will be a made to measure product, meaning its dimensions will be dictated by the specific roofing and energy requirements of the customer, the issue of flow distribution and its effect on both thermal and photovoltaic performance raises some concern. In order to quantify the detrimental effect flow distribution may have on the photovoltaic output of a BIPVT array, a numerical approach was presented by authors in earlier work where factors known to influence flow distribution were varied. The authors demonstrated that photovoltaic output may be severely hindered if the issue of flow distribution is not adequately addressed. In this new study we use this numerical method to additionally show that photovoltaic output is not always improved by reducing the fin width W (by increasing the number of risers for each module) despite the theoretical rise in fin efficiency F as a consequence of flow distribution. Under certain scenarios it was shown that a single riser will in fact improve PV output and also reduce system installation cost and complexity. The combination of these new finding and results previously obtained by the authors highlights the need in selecting the optimal design parameters to meet the specific requirements of each installation. The numerical approach carried out to calculate PV output however was time consuming and computationally intensive and therefore not feasible to perform for each and every customer. To address this issue, the authors have proposed in this paper to train an artificial neural network which can be used to approximate the photovoltaic yield of an array of specified shape operating under parallel{minus 45 degree rule}reverse flow in the manifolds and also with one or two fluid channels cooling each string of cells. By approximating the yield for each scenario, the optimal configuration can then be chosen. It was found that the neural network can be successfully trained for this specific application offering a fast alternative to the original numerical approach.
  • Item type:Publication,
    Comparison of simulation and experimental results of a tractor seat with nonlinear stiffness and dead-band damping
    2012, American Society of Mechanical Engineers (ASME)
    A low friction tractor seat with nonlinear stiffness and dead-band damping was investigated both by simulation and experimentation. The objective was to determine if a practical, soft suspension system could be developed that offered improved vibration performance compared to a typical mechanical commercial tractor seat suspension. A hard damper was used to prevent end stop impacts that were more likely with the soft suspension. In addition the damper had a dead-band centered at the seat's static equilibrium position. The dead-band damping was achieved with a switchable damper using relative seat displacement as the control signal. The objective of the dead-band was to allow a soft undamped operating region that gave good vibration attenuation. If the relative seat displacement passed the dead-band limits due to sudden harsh inputs, the hard damping would take over and prevent end stop impacts. An experimental rig with nonlinear seat and switchable damping was built and tested with the same parameters and inputs as those used in the simulations. The simulation and experimental results compared well. Both the simulation and experimental results showed that a combination of nonlinear stiffness and dead-band damping used on a tractor seat gives reduced rms acceleration compared to a linear, conventionally damped seat.
  • Item type:Publication,
    The effect of in-plane boundary conditions on the post-buckling behaviour of rectangular corrugated paperboard panels
    2012, Elsevier
    The effect of different in-plane boundary conditions on the critical load and post-buckling behaviour of a uniaxially compressed, simply supported corrugated paperboard panel is examined, with the aim of reducing the discrepancy between model and published experimental results. In-plane boundary conditions with uniform load distribution or uniform compression on the loaded edges, free or constant normal in-plane edge movement and shear free edges, are modelled. Analytical single-term Galerkin and finite element approaches are used. The critical loads obtained analytically and numerically, for different boundary conditions agree well with an analytical reference result.
  • Item type:Publication,
    Numerical determination of parasitic resistances of a solar cell using the Lambert W-function
    2011, Elsevier
    Several methods are currently available to determine the values of series and shunt resistance of a solar cell. A new method is presented here to numerically locate these values using the popular Newton–Raphson technique at maximum power point. Equations based on the Lambert W-function and their partial derivatives are provided so that all calculations may be performed in a Matlab or similar environment. The results of this new method are presented and compared with two published methods and the analytically obtained for a blue and grey type solar cell in earlier work (Charles et al., 1981). Additionally, three modules of various type (single, poly, and amorphous crystalline) were investigated. Values determined agreed with experimentally verified results and were obtained with quadratic convergence in all instances provided initial estimates of the roots were within vicinity of the actual roots.