University of Waikato Research
Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288
Browse
21 results
Search Results
Item type:Publication, Design and construction of a configurable full-field range imaging system for mobile robotic applications2011, Springer VerlagMobile robotic devices rely critically on extrospection sensors to determine the range to objects in the robot’s operating environment. This provides the robot with the ability both to navigate safely around obstacles and to map its environment and hence facilitate path planning and navigation. There is a requirement for a full-field range imaging system that can determine the range to any obstacle in a camera lens’ field of view accurately and in real-time. This paper details the development of a portable full-field ranging system whose bench-top version has demonstrated sub-millimetre precision. However, this precision required non-real-time acquisition rates and expensive hardware. By iterative replacement of components, a portable, modular and inexpensive version of this full-field ranger has been constructed, capable of real-time operation with some (user-defined) trade-off with precision.Item type:Publication, Improved measurement linearity and precision for AMCW time-of-flight range imaging cameras2010, Optical Society of AmericaTime-of-flight range imaging systems utilizing the amplitude modulated continuous wave (AMCW) technique often suffer from measurement nonlinearity due to the presence of aliased harmonics within the amplitude modulation signals. Typically a calibration is performed to correct these errors. We demonstrate an alternative phase encoding approach that attenuates the harmonics during the sampling process, thereby improving measurement linearity in the raw measurements. This mitigates the need to measure the system’s response or calibrate for environmental changes. In conjunction with improved linearity, we demonstrate that measurement precision can also be increased by reducing the duty cycle of the amplitude modulated illumination source (while maintaining overall illumination power).Item type:Publication, Multiple frequency range imaging to remove measurement ambiguity2009Range imaging systems use a specialised sensor to capture an image where object distance (range) is measured for every pixel using time-of-flight. The scene is illuminated with an amplitude modulated light source, and the phase of the modulation envelope of the reflected light is measured to determine flight time, hence object distance for each pixel. As the modulation waveform is cyclic, an ambiguity problem exists if the phase shift exceeds 2π radians. To overcome this problem we demonstrate a method that superposes two different modulation frequencies within a single capture. This technique reduces the associated overhead compared with performing two sequential measurements, allowing the system to retain high range measurement precision at rapid acquisition rates. A method is also provided to avoid interference from aliased harmonics during sampling, which otherwise contaminate the resulting range measurement. Experimental results show the potential of the multiple frequency approach; producing high measurement precision while avoiding ambiguity. The results also demonstrate the limitation of this technique, where large errors can be introduced through a combination of a low signal to noise ratio and suboptimal selection of system parameters.Item type:Publication, Maximizing precision over extended unambiguous range for TOF range imaging systems2010, IEEEThe maximum unambiguous range for time-of-flight range imaging systems is inversely proportional to the chosen modulation frequency. However, increasing the unambiguous range by decreasing the modulation frequency will generally also degrade the range measurement precision. We describe a technique that significantly extends the range of a time-of-flight imaging system without compromising range precision. This is achieved by employing two modulation frequencies simultaneously. The chosen frequencies can be a combination of high and low frequency, or two similarly high frequencies. In this paper we present experimental results comparing single frequency; dual high and low frequency; and dual high frequency operation and demonstrate that range precision need not be appreciably compromised to achieve an extended unambiguous range.Item type:Publication, Development of a real-time full-field range imaging system2009, Springer-Verlag Berlin HeidelbergThis article describes the development of a full-field range imaging system employing a high frequency amplitude modulated light source and image sensor. Depth images are produced at video frame rates in which each pixel in the image represents distance from the sensor to objects in the scene. The various hardware subsystems are described as are the details about the firmware and software implementation for processing the images in real-time. The system is flexible in that precision can be traded off for decreased acquisition time. Results are reported to illustrate this versatility for both high-speed (reduced precision) and high-precision operating modes.Item type:Publication, Characterizing an image intensifier in an full-field range image system2008, IEEEWe are developing a high precision full-field range imaging system. An integral component in this system is an image intensifier, which is modulated at frequencies up to 100 MHz. The range measurement precision is dictated by the image intensifier performance, in particular, the achievable modulation frequency, modulation depth, and waveform shape. By characterizing the image intensifier response, undesirable effects can be observed and quantified with regards to the consequence on the resulting range measurements, and the optimal operating conditions can be selected to minimize these disturbances. The characterization process utilizes a pulsed laser source to temporally probe the gain of the image intensifier. The laser is pulsed at a repetition rate slightly different to the image intensifier modulation frequency, producing a continuous phase shift between the two signals. A charge coupled device samples the image intensifier output, capturing the response over a complete modulation period. Deficiencies in our measured response are clearly identifiable and simple modifications to the configuration of our electrical driver circuit improve the modulation performance.Item type:Publication, Development and characterisation of an easily configurable range imaging system2009, IEEERange imaging is becoming a popular tool for many applications, with several commercial variants now available. These systems find numerous real world applications such as interactive gaming and the automotive industry. This paper describes the development of a range imaging system employing the PMD-19 k sensor from PMD technologies. One specific advantage of our system is that it is extremely customisable in terms of modulation patterns to act as a platform for further research into time-of-flight range imaging. Experimental results are presented giving an indication of the precision and accuracy of the system, and how modifying certain operating parameters can improve system performance.Item type:Publication, Heterodyne range imaging in real-time2008, IEEE XploreA versatile full-field range imaging system has previously been constructed. This system is configurable in software to produce either high precision or fast acquisition range images. Indicatively a 10 second exposure has been shown to produce a range image of sub-millimeter precision, whilst video frame rate (30 fps) acquisition provides for centimetre precision. Currently the acquisition time of the system is to a large degree constrained by the off-line processing of the frames by an external computer. This paper presents an alternative to the off-line PC image processing utilising an Altera Stratix II FPGA. Processing rates up to 30 frames per second have been achieved with the added advantage that many of the previous systempsilas existing digital electronics can also be accommodated, providing for an even more compact and flexible system.Item type:Publication, Characterization of modulated time-of-flight range image sensors2009, SPIE and IS&TA number of full field image sensors have been developed that are capable of simultaneously measuring intensity and distance (range) for every pixel in a given scene using an indirect time-of-flight measurement technique. A light source is intensity modulated at a frequency between 10–100 MHz, and an image sensor is modulated at the same frequency, synchronously sampling light reflected from objects in the scene (homodyne detection). The time of flight is manifested as a phase shift in the illumination modulation envelope, which can be determined from the sampled data simultaneously for each pixel in the scene. This paper presents a method of characterizing the high frequency modulation response of these image sensors, using a pico-second laser pulser. The characterization results allow the optimal operating parameters, such as the modulation frequency, to be identified in order to maximize the range measurement precision for a given sensor. A number of potential sources of error exist when using these sensors, including deficiencies in the modulation waveform shape, duty cycle, or phase, resulting in contamination of the resultant range data. From the characterization data these parameters can be identified and compensated for by modifying the sensor hardware or through post processing of the acquired range measurements.Item type:Publication, Improved linearity using harmonic error rejection in a full-field range imaging system2008, SPIE-IS&T (CD-ROM)Full field range imaging cameras are used to simultaneously measure the distance for every pixel in a given scene using an intensity modulated illumination source and a gain modulated receiver array. The light is reflected from an object in the scene, and the modulation envelope experiences a phase shift proportional to the target distance. Ideally the waveforms are sinusoidal, allowing the phase, and hence object range, to be determined from four measurements using an arctangent function. In practice these waveforms are often not perfectly sinusoidal, and in some cases square waveforms are instead used to simplify the electronic drive requirements. The waveforms therefore commonly contain odd harmonics which contribute a nonlinear error to the phase determination, and therefore an error in the range measurement. We have developed a unique sampling method to cancel the effect of these harmonics, with the results showing an order of magnitude improvement in the measurement linearity without the need for calibration or lookup tables, while the acquisition time remains unchanged. The technique can be applied to existing range imaging systems without having to change or modify the complex illumination or sensor systems, instead only requiring a change to the signal generation and timing electronics.