University of Waikato Research
Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288
Browse
12 results
Search Results
Item type:Publication, How positioning wearable haptic interfaces on limbs influences virtual embodiment2024, IEEEWith increasing use of computer applications and robotic devices in our everyday life, and with the advent of metaverse, there is an urgent need of developing new types of interfaces that facilitate a more intuitive interaction in physical and virtual space. In this work, we investigate the influence of the location of haptic feedback devices on embodiment of virtual hands and user load during an interactive pick-and-place task. To do this, we conducted a user study with a 3x2 repeated measure experiment design: feedback position is varied between the distal phalanx of the index finger and the thumb, the proximal phalanx of the index finger and the thumb, and the wrist. These conditions of feedback are tested with the stimuli applied synchronously to the participant in one case, and with an additional delay of 350 ms in the second case. The results show that the location of the haptic feedback device does not affect embodiment, whereas the delay, i.e., whether the feedback is applied synchronously or asynchronously, affects embodiment. This suggests that for pick-and-place tasks, haptic feedback devices can be placed on the user's wrist without compromising performance making the hands to remain free, allowing unobstructed hand visibility for precise motion tracking, thereby improving accuracy.Item type:Publication, A video dataset of everyday life grasps for the training of shared control operation models for myoelectric prosthetic hands2024, IEEEThe control of high degree of freedom prosthetic hands requires high cognitive effort and has proven difficult to navigate particularly as prosthetic hands become more advanced. To reduce control complexity, vision-based shared control methods have been proposed. Such methods rely on image processing and/or machine learning to identify object features and classes and introduce a level of autonomy to the grasping process. However, currently available image datasets lack focus in the area of prosthetic grasping. Thus, in this paper, we present a new dataset capturing user interactions with a wide variety of everyday life objects using a fully actuated, human-like robot hand and an onboard camera. The dataset includes videos of over 100 grasps of 50 objects from 35 classes. A video analysis has been conducted, using established grasp taxonomies to compile a list of grasp types based on interactions of the user with the objects. The resulting dataset can be used to develop more efficient prosthetic hand operation systems based on shared control frameworks.Item type:Publication, Multi-grasp classification for the control of robot hands employing transformers and lightmyography signals2023, IEEEThe increasing use of smart technical devices in our everyday lives has necessitated the use of muscle-machine interfaces (MuMI) that are intuitive and that can facilitate immersive interactions with these devices. The most common method to develop MuMIs is using Electromyography (EMG) based signals. However, due to several drawbacks of EMG-based interfaces, alternative methods to develop MuMI are being explored. In our previous work, we presented a new MuMI called Lightmyography (LMG), which achieved outstanding results compared to a classic EMG-based interface in a five-gesture classification task. In this study, we extend our previous work experimentally validating the efficiency of the LMG armband in classifying thirty-two different gestures from six participants using a deep learning technique called Temporal Multi-Channel Vision Transformers (TMC-ViT). The efficiency of the proposed model was assessed using accuracy. Moreover, two different undersampling techniques are compared. The proposed thirty-two-gesture classifiers achieve accuracies as high as 92%. Finally, we employ the LMG interface in the real-time control of a robotic hand using ten different gestures, successfully reproducing several grasp types from taxonomy grasps presented in the literature.Item type:Publication, Navigating the challenges of wearables: A case study of research-grade devices2025, ACMThe use of wearable devices in HCI research is becoming more common. However, it is also widely accepted that there are challenges associated with the use of wearable devices. Researchers have investigated generalized challenges, and more recently, challenges associated with low-cost commercial devices. Yet, little work has been published on the challenges of working with higher-cost research-grade devices. In this paper, we use a case study to explore the challenges associated with research-grade devices, and compare these challenges with those that have been identified by other researchers. The case study involves the use of two research-grade devices to record a series of physiological data-points. The case study identified one new challenge that is associated with research-grade wearable devices (setup complexity (researcher adoption)) and highlighted similarities between generalized challenges, low-cost device challenges, and research-grade challenges. The findings from this work can be used to further investigate challenges associated with wearable devices.Item type:Publication, Muscle myography for human-machine interfaces: A review of sensing modalities and control interfaces2026, FrontiersMuscle myography encompasses a family of techniques for sensing muscle activity through its electrical, mechanical, and optical manifestations, offering non-invasive and embodied pathways for human–machine interaction. Unlike traditional input devices that are hand-centric and device-bound, myography-based interfaces enable hands-free, inclusive control for prosthetics, exoskeletons, teleoperation, and immersive computing, while also opening opportunities in rehabilitation and health monitoring. This review surveys the state of muscle myography with an emphasis on its implications for human–machine interfaces (HMIs). We examine established and emerging modalities—including electromyography (EMG), mechanomyography (MMG), forcemyography (FMG), electrical impedance myography (EIM), optomyography (OMG), and the recently introduced lightmyography (LMG)—highlighting their respective strengths, weaknesses, and the trade-offs between signal quality, robustness, and wearability. We also identify recurring challenges such as limb position effects, motion artifacts, sensor reliability, and clinical acceptability, and discuss strategies such as hybrid sensing, sensor fusion, and machine learning aimed at mitigating these issues. For the HMI community, the significance of muscle myography lies not only in technical performance but also in its potential to redefine interaction design, shifting toward interfaces that operate less as external devices and more as natural extensions of the human body.Item type:Publication, A multimodal bracelet to acquire muscular activity and gyroscopic data to study sensor fusion for intent detection2024, MDPIResearchers have attempted to control robotic hands and prostheses through biosignals but could not match the human hand. Surface electromyography records electrical muscle activity using non-invasive electrodes and has been the primary method in most studies. While surface electromyography-based hand motion decoding shows promise, it has not yet met the requirements for reliable use. Combining different sensing modalities has been shown to improve hand gesture classification accuracy. This work introduces a multimodal bracelet that integrates a 24-channel force myography system with six commercial surface electromyography sensors, each containing a six-axis inertial measurement unit. The device’s functionality was tested by acquiring muscular activity with the proposed device from five participants performing five different gestures in a random order. A random forest model was then used to classify the performed gestures from the acquired signal. The results confirmed the device’s functionality, making it suitable to study sensor fusion for intent detection in future studies. The results showed that combining all modalities yielded the highest classification accuracies across all participants, reaching (Formula presented.) on average, effectively reducing misclassifications by 37% and 22% compared to using surface electromyography and force myography individually as input signals, respectively. This demonstrates the potential benefits of sensor fusion for more robust and accurate hand gesture classification and paves the way for advanced control of robotic and prosthetic hands.Item type:Publication, Editorial: Wearables for human-robot interaction and collaboration2025-12-09, FrontiersWearable devices and related technologies have become deeply embedded in daily life. From consumer electronics to healthcare and industrial automation, wearables are now ubiquitous, enabling seamless interaction between humans and machines and fundamentally transforming modern lifestyles. Devices such as smartwatches, intelligent armbands and gloves, smart insoles, and VR headsets are increasingly popular to support fitness, healthcare, and telepresence operations. At the same time, personalized wearable robots, including exoskeletons, prosthetic limbs, and supernumerary robotic arms, provide real-time physical support for rehabilitation, human motor restoration, and enhancement of capabilities. By inferring human intentions and interpreting behavioral and physiological signals, these systems are reshaping the foundations of human–robot interaction and collaboration. With the rise of concepts such as human-centered design and Tri-cobots (coexisting–cooperative–cognitive robots), the development of wearable technologies has been accelerating.Item type:Publication, Offline versus real-time grasp prediction employing a wearable high-density lightmyography armband: On the control of prosthetic hands2025-04-01, IEEESeveral studies over the last decades have investigated the use of myoelectric upper-arm prostheses to restore lost functionality and perform complex activities of daily life. Muscle-machine interfacing methods employing electromyography, sonomyography, forcemyography, and mechanomyography, have been developed offering users intuitive control of prostheses. However, these methods suffer their own drawbacks and the practical, robust, real-time control of prostheses in the execution of complex everyday life tasks remains difficult to accomplish. In this study, a wearable high-density lightmyography armband is proposed, and the offline and real-time grasp prediction schemes are compared in an attempt to deepen our understanding in real-time decoding employing lightmyography signals. Thus bringing lightmyography closer to advanced real-time prosthetic control scenarios. Offline experiments were conducted where models decoding 10 classes were trained and tested, achieving accuracies exceeding 91% with a mean of 94.11% when a Random Forest model was employed and a mean of 95.87% when a Convolutional Neural Networks model was employed. However, as models were deployed in real-time, a decline in performance was notable, reducing the accuracies to 60-70%. Other limitations were observed in this transition. Although average accuracies were high, the precision and recall for a small fraction of grasps were often low, hindering overall real-time performance. Moreover, prolonged usage led to decreased decoding accuracy, with accuracies dropping to below 35%, indicating that fatigue, sweat, or sensor shift may have affected the signals over time. Thus for the real-time application of lightmyography, it is recommended to discriminate between a smaller number of classes for which accuracies are higher (around 80% for 6 classes without prolonged use).Item type:Publication, A database of multimodal myography and hand kinematics during realistic daily life activities2025-08-28, NatureThis paper introduces MyoKi, a database capturing multimodal myography and hand kinematics during various realistic daily life activities. MyoKi emphasizes the complexity of real-world settings, addressing limitations of existing databases, which often reflect controlled laboratory conditions. The database includes two subsets of participants designed to evaluate different sensor configurations. Both subsets contain surface electromyography (sEMG) and inertial measurement unit (IMU) data, along with hand kinematics covering 18 finger and wrist joints. For the second subset, additional force myography (FMG) data was collected. The database captures hand movements of 35 participants performing 74 tasks, with varying arm orientations and movements involving different grips and motions. By offering detailed participant profiles and systematically categorizing each task, the MyoKi database enables in-depth exploration of task complexity, sensor influence, and the impact of demographic and anthropometric factors on control system performance. The database is designed to facilitate research in continuous hand control, enhancing the robustness and reliability of myoelectric devices for daily activities, moving towards user-friendly and effective control of robotic and prosthetic hands.Item type:Publication, A wearable bidirectional human–machine interface: Merging motion capture and vibrotactile feedback in a wireless bracelet2024, MDPIHumans interact with the environment through a variety of senses. Touch in particular contributes to a sense of presence, enhancing perceptual experiences, and establishing causal relations between events. Many human–machine interfaces only allow for one-way communication, which does not do justice to the complexity of the interaction. To address this, we developed a bidirectional human–machine interface featuring a bracelet equipped with linear resonant actuators, controlled via a Robot Operating System (ROS) program, to simulate haptic feedback. Further, the wireless interface includes a motion sensor and a sensor to quantify the tightness of the bracelet. Our functional experiments, which compared stimulation with three and five intensity levels, respectively, were performed by four healthy participants in their twenties and thirties. The participants achieved an average accuracy of 88% estimating three vibration intensity levels. While the estimation accuracy for five intensity levels was only 67%, the results indicated a good performance in perceiving relative vibration changes with an accuracy of 82%. The proposed haptic feedback bracelet will facilitate research investigating the benefits of bidirectional human–machine interfaces and the perception of vibrotactile feedback in general by closing the gap for a versatile device that can provide high-density user feedback in combination with sensors for intent detection.