<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

University of Waikato Research

Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288

Browse

Search Results

Now showing 1 - 10 of 10
  • Item type:Publication,
    Web crippling behaviour of cold-formed steel channel sections having elongated edge-stiffened web holes under interior-two-flange loading condition
    2023-11-01, Elsevier
    In the past decade, cold-formed steel (CFS) channel sections having circular edge-stiffened web holes have been developed in New Zealand. Such edge-stiffened holes increase the strength of the CFS channel sections, compared to an equivalent section having unstiffened holes, while still allowing full service integration. In the case of web crippling, previous research has found that use of edge-stiffened holes almost results in the same strength of an equivalent channel-section having a plain web. Such circular edge-stiffened web holes can now be extended to elongated edge-stiffened web holes. However, for such elongated holes, no experimental tests have been reported in the literature. In this paper, a numerical investigation was carried out, and non-linear finite element (FE) analyses were used to investigate the web crippling behaviour of CFS channel sections having edge-stiffened web holes under the interior-two-flange (ITF) loading condition. The cases of both flange fastened and flange unfastened were considered. The FE models were validated against test results of sections having circular edge-stiffened web holes; good agreement in terms of the load–displacement curves and deformed shapes was shown. Using the validated FE models, a parametric study was carried out on CFS channel sections having elongated un-stiffened and edge-stiffened web holes, comprising 1,227 finite element analyses (FEA) results. Compared to sections having a plain web, for the case of an elongated opening, without any edge-stiffener, having an aspect ratio of two and three, the average reduction in web crippling strength was 39% and 49%, respectively. However, for an edge-stiffened hole, the reduction in the web crippling strength was reduced to only 2% and 16%, respectively. Finally, the design equations in the form of the web crippling reduction factor (Rp) and the equations based on the direct strength method (DSM) for CFS sections with elongated web holes were proposed.
  • Item type:Publication,
    Web crippling design of cold-formed stainless steel channels under interior-two-flange loading condition using deep belief network
    2023-01, Elsevier
    This research presents a deep-learning framework, namely a deep belief network (DBN), for analyzing the interior-two-flange web crippling performance of cold-formed stainless steel channels with centered and offset web holes. An elastoplastic finite element (FE) model, validated using 101 experimental results which were previously reported in the literature, generates a total of 43,200 data points for training the DBN. When compared to a total of 54 experimental results published in the literature, the DBN predictions were shown to be approximately 10% more conservative. Using the same large training data, the developed DBN model outperformed the Backpropagation Neural Network (a typical shallow artificial neural network) and the PaddlePaddle-based linear regression model. A parametric analysis was then performed using the DBN predictions to explore the effect of section size, web holes and bearing length. Design equations for (reduced) web crippling strength are proposed for the cold-formed stainless steel perforated channels, and the feasibility of the proposed equations was assessed by the conducted reliability analysis.
  • Item type:Publication,
    Numerical investigation of cold-formed steel channels with edge-stiffened and unstiffened elongated web holes under shear
    2024, Elsevier BV
    Over the past decade, cold-formed steel (CFS) channel sections having edge-stiffened circular web holes have been developed in New Zealand. Such edge-stiffened holes increase the strength of the CFS channel sections, compared to an equivalent section having unstiffened web holes, while still allowing full building service integration. In the case of shear, previous research has found that the use of edge-stiffened web holes significantly improves the shear strength of such channel sections. However, no studies are available in the literature investigating the shear strength of CFS channel sections with edge-stiffened elongated web holes. The issue is addressed herein. Non-linear finite element (FE) analyses are used to investigate the shear strength of CFS channel sections with a shear span aspect ratio of 2.0. The FE models were validated against the experimental test results of sections having unstiffened elongated web holes and edge-stiffened circular web holes; good agreement in terms of the load-displacement curves and failure behaviour was shown. Using the validated FE models, a parametric study was conducted, comprising 2124 finite element analyses (FEA) results. The parametric results were then compared to the design predictions of the American Iron and Steel Institute (AISI 2016), and Australia/New Zealand Standards (AS/NZS 2018) and Wanniarchchi et al. (2017) for unstiffened elongated web holes, showing that the design predictions are unconservative in comparison results. Moreover, the direct strength method (DSM) approach of Pham et al. (2020a and 2023) provides conservative results for channels with unstiffened elongated web holes. It was also found that the design equations proposed by Chen et al. (2022) for edge-stiffened circular web holes were unconservative in predicting the shear strength of channels having edge-stiffened elongated web holes. Therefore, design equations in the form of a shear reduction factor and a modified DSM approach for CFS channel sections having unstiffened and edge-stiffened elongated web holes were proposed. Finally, a reliability analysis was carried out to ensure that the proposed equations are reliable to predict the shear strength of CFS channel sections with edge-stiffened and unstiffened web holes.
  • Item type:Publication,
    Integrating occupancy density into the environmental assessment of residential buildings: Towards embodied impact reduction at both building and urban level
    2025, Elsevier BV
    Life Cycle Assessments (LCA) of buildings typically use gross floor area (GFA)-centric functional units, while urban-scale assessments use occupancy-centric ones. This mismatch reflects the dual functions of buildings (providing space and shelter) and can lead to conflicting strategies, where reducing impacts per GFA at the building level may increase impacts per occupant at the urban level. This study compares these assessment approaches and introduces a dual-functional unit approach that evaluates buildings across both functions. Eight detached houses are assessed using LCA across four impact categories and ranked using a multi-criteria decision-making (MCDM) method for each approach. Results show significant variation in rankings among the established approaches, with several buildings having completely opposite outcomes (e.g., ranked 1st in the GFA-centric assessment but 6th in the occupancy-centric assessment), while the proposed approach produces more consistent rankings, representing both functions. Moreover, a scenario-based analysis compares the three assessments to a control (no-assessment) scenario, considering all detached houses built in Aotearoa New Zealand over the past 5 years. The GFA-centric assessment resulted in increased total impacts (mean difference +0.20% across the four impact categories) by promoting larger and less dense buildings (+0.70 m² per occupant), while the occupancy-centric assessment led to mean impact reductions of -1.98%, while significantly reducing the space per occupant by 0.98m². The proposed approach achieved even greater impact reductions (-2.22%) while reducing space by only 0.31m² per occupant. Finally, a correlation with national climate goals was made, showing the approach could achieve 71.65% of the national carbon reduction target.
  • Item type:Publication,
    A novel machine learning model to predict the moment capacity of cold-formed steel channel beams with edge-stiffened and un-stiffened web holes
    2022, Elsevier BV
    A novel machine learning model, eXtreme Gradient Boosting (XGBoost), was used for the purpose of evaluating the moment capacity of cold-formed steel (CFS) channel beams with edge-stiffened web holes subject to bending. A total of 1620 data points were generated for training the XGBoost model, using an elasto-plastic finite element model which was validated against 12 sets of test data taken from the existing literature. The R2 score of XGBoost predictions for the moment capacity was around 99%. The performance of current design equations was evaluated through the comparison of their results against those obtained from the XGBoost model. The moment capacities obtained from the XGBoost testing dataset were also compared with that determined from the existing design equations for un-stiffened holes (USH) and edge-stiffened holes (ESH). The moment capacities determined from the current design equations for USH and ESH were found to be excessively conservative by 38.3%, and unconservative by 36.2% on average, respectively. Therefore, new design equations were proposed based on the results of parametric study using the XGBoost model. In the detailed parametric analysis, the effects of web depth, section thickness, and beam length on the moment capacity of channel beams (CFSCB) with ESH were considered. From the results of XGBoost outputs, the absolute percentage error of new design equations for that based on the strengths of unperforated CFSCB was 8.78%, and for that based on the strengths of CFSCB with USH, the absolute percentage error was 13.7%. Additionally, a reliability analysis was performed to evaluate the accuracy of the proposed equations that were used to predict the moment capacity of CFS channel beams with ESH subject to bending. The reliability indices of all the proposed equations were greater than 2.5 which can be reliable as per the guidelines of AISI.
  • Item type:Publication,
    Local and distortional buckling behaviour of aluminium alloy back-to-back channels with web holes under axial compression
    2022, Elsevier
    Aluminium alloy back-to-back channels are becoming popular in building structures. These back-to-back channels often include web holes for installation of services. No previous research, however, is available in the literature for compressive behaviour of aluminium alloy back-to-back channels with web holes. This paper presents an experimental and numerical investigation on the behaviour of screw fastened back-to-back built-up aluminium alloy stub and short columns with web holes under axial compression. Fourteen tests were conducted in total, the results of all are reported in this paper. Prior to compression tests, tensile tests were conducted to determine the material properties of test specimens and initial geometric imperfections were also measured using a laser scanner. A non-linear finite element (FE) model was then developed, and the results were compared against the experiment results showing a good match in terms of both the axial strength and failure modes. Based on 720 FE models, a comprehensive parametric study was conducted to investigate the effects of hole size, screw spacing, section thickness, column length and modified slenderness on structural behaviour of back-to-back built-up aluminium alloy channel columns. Furthermore, the performance of current design guidelines by Australian/New Zealand Standards (AS/NZS) and the American Iron and Steel Institute (AISI) standards was assessed by comparing the axial strengths obtained from the experiments and FEA. It is shown that the AISI & AS/NZS (4600:2018) are conservative by 10% on average, when compared against the test results. Parametric study results were used to propose the axial strength reduction factor equations for aluminium alloy back-to-back channels, and thereafter a reliability analysis was performed. The results of reliability analysis showed that the proposed equations could closely predict the reduced axial strength of aluminium alloy back-to-back channels with web holes.
  • Item type:Publication,
    Composite Cold-Formed Steel Beams with Diagonal Rebars for Earthquake-Resistant Buildings
    2023-04-10
    The construction industry is on the lookout for cost-effective structural members that are also environmentally friendly. Built-up cold-formed steel (CFS) sections with minimal thickness can be used to make beams at a lower cost. Plate buckling in CFS beams with thin webs can be avoided by using thick webs, adding stiffeners, or strengthening the web with diagonal rebars. When CFS beams are designed to carry heavy loads, their depth logically increases, resulting in an increase in building floor height. The experimental and numerical investigation of CFS composite beams reinforced with diagonal web rebars is presented in this paper. A total of twelve built-up CFS beams were used for testing, with the first six designed without web encasement and the remaining six designed with web encasement. The first six were constructed with diagonal rebars in the shear and flexure zones, while the other two with diagonal rebars in the shear zone, and the last two without diagonal rebars. The next set of six beams was constructed in the same manner, but with a concrete encasement of the web, and all the beams were then tested. Fly ash, a pozzolanic waste byproduct of thermal power plants, was used as a 40% replacement for cement in making the test specimens. CFS beam failure characteristics, load-deflection behavior, ductility, load-strain relationship, moment-curvature relationship, and lateral stiffness were all investigated. The results of the experimental tests and the nonlinear finite element analysis performed in ANSYS software were found to be in good agreement. It was discovered that CFS beams with fly ash concrete encased webs have twice the moment resisting capacity of plain CFS beams, resulting in a reduction in building floor height. The results also confirmed that the composite CFS beams have high ductility, making them a reliable choice for earthquake-resistant structures.
  • Item type:Publication,
    Feasibility Study of Reclaimed Asphalt Pavements (RAP) as Recycled Aggregates Used in Rigid Pavement Construction.
    2023-02-10
    Reclaimed Asphalt Pavement (RAP) as recycled aggregates is a relatively new construction process of rigid pavements due to the scarcity and degradation of natural aggregates. This study aims at the sequential characterization of RAP aggregate to obtain optimized proportions for strength. For this purpose, RAP aggregates were used for the replacement of natural aggregates (NA) in the concrete mix which was achieved by varying from 0-100%. Furthermore, zirconia silica fume (ZSF) was used as a partial replacement of the cement in the concrete mix, replacing Ordinary Portland Cement (OPC). Experimental studies have shown that the incorporation of washed RAP (WRAP) slightly reduces the compressive strength of concrete by 2.7-37.35% as compared to the reference control concrete mix. Although the 7-days, 28-days and 56-day compressive strength of WRAP recycled aggregate-based concrete is slightly better than the 7-days, 28-days and 56-day compressive strength of dirty RAP (DRAP) recycled aggregate-based concrete. A similar trend was observed in the flexural strength and split tensile strength of WRAP recycled aggregate-based. Overall, the results show that 40% WRAP recycled aggregates with 10% ZSF as a replacement for cement outperform DRAP aggregates in concrete mixes. According to the ANOVA results, the combination of ZSF and WRAP aggregates met the cement concrete pavement strength standard, thereby contributing to sustainable development. Reclaimed Asphalt Concrete Pavements (RACP) are now seen as a potential and long-term answer to the present environmental and economic crisis.
  • Item type:Publication,
    A State of the Art Review of Fillet Welded Joints
    2022-12-07
    Fillet welded joints are commonly used in steel structures for various engineering applications such as buildings, bridges, railways, ships, and marine structures. Fillet welded joints are generally subjected to static and fatigue loading, resulting in failures of such welded joints. A number of experimental and numerical investigations on the strength and failure behaviour of fillet welded joints have been published. This paper presents a comprehensive review of research results on the static strength, fatigue life, and thermal performance of fillet welded joints. The review covers the various influential factors, such as loading direction, weld geometry, grades of steel, filler materials, welding process, weld penetration, strength mismatch of weld metal, and post-welded treatment. In total, 100 papers were critically reviewed, which were published from 1970 till date. The key findings and research developments on fillet welded joints are summarised. It was found that the transverse fillet welded joints have a higher static strength than the longitudinal fillet welded joints. Filler materials, post-welded treatment, and penetration of weld metal can offer significant strength enhancements in terms of their static and fatigue strength. Lastly, research gaps have been found in the existing body of knowledge, which will help guide future research.
  • Item type:Publication,
    Performance of Sustainable Insulated Wall Panels with Geopolymer Concrete.
    2022-12-09
    The increase in the population creates an increased demand for construction activities with eco-friendly, sustainable, and high-performance materials. Insulated concrete form (ICF) is an emerging technology that satisfies the sustainability demands of the construction sector. ICF is a composite material (a combination of expanded polystyrene (EPS) and geopolymer concrete (GPC)) that enhances the performance of concrete (such as thermal insulation and mechanical properties). To investigate the axial strength performance, five different types of prototypes were created and tested. Type I (without reinforcement): (a) hollow EPS without concrete, (b) alternative cells of EPS filled with concrete, (c) and all the cells of EPS filled with concrete; and Type II (with reinforcement): (d) alternative cells of EPS filled with concrete; (e) and all the cells of EPS filled with concrete. Amongst all the five prototypes, two grades of GPC were employed. M15 and M20 grades are used to examine the effectiveness in terms of cost. For comparing the test results, a reference masonry unit was constructed with conventional clay bricks. The main aim of the investigation is to examine the physical and mechanical performance of sandwich-type ICFs. The presence of polystyrene in ICF changes the failure pattern from brittle to ductile. The result from the study reveals that the Type II prototype, i.e., the specimen with all the cells of EPS filled with concrete and reinforcement, possesses a maximum load-carrying capacity greater than the reference masonry unit. Therefore, the proposed ICF is recommended to replace the conventional load-bearing system and non-load-bearing walls.