  • Item type:Publication,
    Viability of automating the landing error scoring system using inertial measurement units
    2026, Elsevier
    The Landing Error Scoring System (LESS) is an assessment tool used for identifying movement patterns linked with non-contact anterior cruciate ligament injuries during a double-leg jump-landing; however, the LESS is scored by experts using 2D video recordings, which limits large-scale screening. This study explores the viability of using inertial measurement unit (IMU) data to automate scoring of 17 LESS items, using conventional machine learning model architecture. Forty healthy participants completed six jumps each, and raw movement data from three IMU sensors placed on the sacrum and medial-inferior aspects of the tibias were processed and segmented into the key phases of the double-leg jump-landing. A total of 218 jumps were used to train supervised machine learning models using various subsets of the processed dataset, including extracted temporal and statistical features. Performance metrics were extracted, and the best performing models for each scoring item were evaluated against a majority-class baseline classifier (ZeroR). Results indicated moderate improvements over ZeroR, ranging from 0.3 % to 22.5 %, with some models demonstrating limited recognition of the minority class. These findings provide a foundation for future research in IMU-based LESS automation, and improving the accessibility of movement screening tools.
  • Item type:Publication,
    Muscle myography for human-machine interfaces: A review of sensing modalities and control interfaces
    2026, Frontiers
    Muscle myography encompasses a family of techniques for sensing muscle activity through its electrical, mechanical, and optical manifestations, offering non-invasive and embodied pathways for human–machine interaction. Unlike traditional input devices that are hand-centric and device-bound, myography-based interfaces enable hands-free, inclusive control for prosthetics, exoskeletons, teleoperation, and immersive computing, while also opening opportunities in rehabilitation and health monitoring. This review surveys the state of muscle myography with an emphasis on its implications for human–machine interfaces (HMIs). We examine established and emerging modalities—including electromyography (EMG), mechanomyography (MMG), forcemyography (FMG), electrical impedance myography (EIM), optomyography (OMG), and the recently introduced lightmyography (LMG)—highlighting their respective strengths, weaknesses, and the trade-offs between signal quality, robustness, and wearability. We also identify recurring challenges such as limb position effects, motion artifacts, sensor reliability, and clinical acceptability, and discuss strategies such as hybrid sensing, sensor fusion, and machine learning aimed at mitigating these issues. For the HMI community, the significance of muscle myography lies not only in technical performance but also in its potential to redefine interaction design, shifting toward interfaces that operate less as external devices and more as natural extensions of the human body.
  • Item type:Publication,
    15-year patient-reported outcomes of a cemented flanged cup and stem combination in primary total hip arthroplasty: A New Zealand study
    2026, SAGE
    Methods: We investigated 15-year patient-reported outcomes (PROMs) and their predictors in primary total hip arthroplasty (THA) for osteoarthritis using a cemented flanged cup and stem from a regional joint registry in New Zealand. Regional data were collected for all primary THAs with this cemented combination from 1 January 2003 to 30 June 2023 who had recorded PROMs on at least 1 occasion (n = 263). PROMs included Oxford Hip Score, Western Ontario and McMaster Universities Arthritis Index and Veterans Rand-12, evaluated against patient age, ethnicity, sex, body mass index (BMI), funding pathway, and American Society of Anesthesiologists (ASA) rating. Results: Significant improvements across preoperative PROMs were noted 1-year post-surgery, with a mean change above 23 in the Oxford Hip Score maintained at 5, 10, and 15 years (p ⩽ 0.001). Conclusions: Regression analysis indicated that being female, public funding, and higher BMI were associated with worse preoperative PROMs. Poorer preoperative scores, older age and ASA 3 rating correlated with poorer postoperative outcomes.
  • Item type:Publication,
    Low-cost Ti alloys: Assessment of their microstructure, mechanical properties, corrosion behaviour, and biological response
    2026, Elsevier
    Orthopaedic and dental implants, the majority of which are made from titanium alloys, face the crucial challenge of both inducing osteogenesis whilst inhibiting bacterial biofilm formation in an economical manner over the life of the implant. This study introduces an innovative strategy combining cost-effective alloying elements, selected due to their reported biological benefits, for developing new titanium alloys that achieve a tailorable mechanical, corrosion, and biological response. The combination of alloying and manufacturing results in homogeneous materials characterised by a lamellar microstructure. The developed low-cost Ti alloys have a maximum ultimate compression strength of 659 MPa, maximum tensile yield stress of 606 MPa, and maximum elongation of 8.3% without failing catastrophically. The alloys do not degrade as abiotic corrosion is significantly hampered by their intrinsic passivation behaviour (maximum corrosion rate of 8.9 μm/year), and have adjustable surface wettability with contact angles in the 60-81° range. Consequently, stomal cell attachment, cytotoxicity and cytokine production (IL-6 and TGF-β1), and antibacterial rate on S. aureus are consistent and comparable to those of current implnat materials. Based on these characteristics, the low-cost Ti alloys are promising materials for load-bearing biomedical devices.
  • Item type:Publication,
    Footstrike evaluation in male runners: A comparison of lateral and medial video views against traditional motion capture
    2025-09, Elsevier
    Footstrike evaluation is essential for understanding running biomechanics and is often performed in research and clinical settings using 2D video analysis. However, whether it is appropriate to analyse both right-left footstrike patterns from a single sagittal plane video is unclear. This study compared medial and lateral video views in assessing footstrike pattern and footstrike angle, using a motion capture system as the gold standard. We analyzed 4,800 footfalls from 20 healthy recreational runners during self-paced treadmill running, recruited through convenient sampling. Footstrike angle agreement was evaluated using Bland-Altman analysis, intraclass correlation coefficients (ICC), and root mean square error (RMSE). The mean difference in footstrike angle between the gold standard and lateral view was 0.40° (95% limits of agreement: 6.05° to −5.25°), while the medial view showed a mean difference of −1.31° (95% limits: 8.37° to −10.99°). ICC values indicated excellent agreement for both lateral (0.979) and medial (0.940) views to the gold standard. RMSE was lower for the lateral (2.91°) than medial (5.11°) view, suggesting greater precision. Footstrike pattern classification was assessed using Cohen's kappa, revealing substantial agreement for the lateral view (κ = 0.785, p < 0.001) and good agreement for the medial view (κ = 0.606, p < 0.001). These results indicate that while both views demonstrate strong agreement, the lateral view aligns more closely with the gold standard in continuous and categorical assessments. Our findings suggest lateral video analysis may be preferable for footstrike evaluation in applied and clinical settings.
  • Item type:Publication,
    Maximize or normalize? Examining single-leg drop-land-cut distances in young athletes: A pilot study
    2025, Human Kinetics
    This study investigated differences in leap distance for a single-leg drop-land-cut (CUT) task based on using either a maximal or normalized (150% leg length) method or the influence of condition order and leg dominance on distance achieved. Twenty-six young court and field sport athletes (61.5% female) completed the single-leg drop-land-cut task on the dominant and nondominant leg under maximal and normalized conditions in a randomized order. Multivariate repeated measures analysis of variance tests with post hoc pairwise comparisons were used to determine the effect of condition (maximal and normalized), leg dominance (dominant and nondominant), and interaction effect on leaping distance. Potential order effects were explored as a between-subjects factor within the analysis of variance. Our findings showed significantly larger leap distances under the maximal condition (P < .001, η2p ≥ .417), with the maximal mean being 154.5 (24.7) cm (175.1% [18.6%] leg length) and the normalized mean being 140.7 (19.7) cm (159.0% [5.8%] of leg length). Furthermore, greater distances were achieved during the maximal task when performed following the normalized task (P < .001, 24.5% further). Practically, the normalized task may be better suited for heterogeneous samples; yet, the maximal task may be more suitable for homogeneous samples or pre–post study designs.
  • Item type:Publication,
    Supercapacitor-based pulse generator with waveform adjustment capability for small animal transcranial magnetic stimulation
    2024, IOP Publishing
    In transcranial magnetic stimulation (TMS), pulsed magnetic fields are applied to the brain, typically requiring high-power stimulators with high voltages and low series impedance. TMS pulse generators for small animal coils, are underexplored, with limited dedicated circuits and simulation models. Here, we present a new design for a high-power TMS pulse generator for small animals, utilizing a pre-charged supercapacitor that is sufficient to produce repeated pulses for TMS applications without the need for recharging. This approach eliminates the need for expensive high-voltage components and a high-voltage power supply. In this paper, we detail the design approach and basic block diagrams of a supercapacitor (SC) based TMS pulse generator, along with its experimental results. The findings indicate that the new circuit enables a complete test using just a single charge of an SC module. The proposed circuit functions as a versatile pulse-shaping device, where the MOSFET is treated as a dynamically varying resistor element rather than a traditional switch; allowing pulse parameter variations. We analyze a novel circuit for generating and controlling TMS pulses in small animal coils, and demonstrate its effectiveness through experimental results.