Now showing 1 - 4 of 4
  • Item type:Publication,
    A power-saving modulation technique for time-of-flight range imaging sensors
    2011, Society of Photo-Optical Instrumentation Engineers
    Time-of-flight range imaging cameras measure distance and intensity simultaneously for every pixel in an image. With the continued advancement of the technology, a wide variety of new depth sensing applications are emerging; however a number of these potential applications have stringent electrical power constraints that are difficult to meet with the current state-of-the-art systems. Sensor gain modulation contributes a significant proportion of the total image sensor power consumption, and as higher spatial resolution range image sensors operating at higher modulation frequencies (to achieve better measurement precision) are developed, this proportion is likely to increase. The authors have developed a new sensor modulation technique using resonant circuit concepts that is more power efficient than the standard mode of operation. With a proof of principle system, a 93–96% reduction in modulation drive power was demonstrated across a range of modulation frequencies from 1–11 MHz. Finally, an evaluation of the range imaging performance revealed an improvement in measurement linearity in the resonant configuration due primarily to the more sinusoidal shape of the resonant electrical waveforms, while the average precision values were comparable between the standard and resonant operating modes.
  • Item type:Publication,
    Illumination waveform optimization for time-of-flight range imaging cameras
    2011, Society of Photo-Optical Instrumentation Engineers
    Time-of-flight range imaging sensors acquire an image of a scene, where in addition to standard intensity information, the range (or distance) is also measured concurrently by each pixel. Range is measured using a correlation technique, where an amplitude modulated light source illuminates the scene and the reflected light is sampled by a gain modulated image sensor. Typically the illumination source and image sensor are amplitude modulated with square waves, leading to a range measurement linearity error caused by aliased harmonic components within the correlation waveform. A simple method to improve measurement linearity by reducing the duty cycle of the illumination waveform to suppress problematic aliased harmonic components is demonstrated. If the total optical power is kept constant, the measured correlation waveform amplitude also increases at these reduced illumination duty cycles. Measurement performance is evaluated over a range of illumination duty cycles, both for a standard range imaging camera configuration, and also using a more complicated phase encoding method that is designed to cancel aliased harmonics during the sampling process. The standard configuration benefits from improved measurement linearity for illumination duty cycles around 30%, while the measured amplitude, hence range precision, is increased for both methods as the duty cycle is reduced below 50% (while maintaining constant optical power).
  • Item type:Publication,
    Calibration and control of a robot arm using a range imaging camera
    2010, IS&T- the Society for Imaging Science and Technology SPIE
    Time of flight range imaging is an emerging technology that has numerous applications in machine vision. In this paper we cover the use of a commercial time of flight range imaging camera for calibrating a robotic arm. We do this by identifying retro-reflective targets attached to the arm, and centroiding on calibrated spatial data, which allows precise measurement of three dimensional target locations. The robotic arm is an inexpensive model that does not have positional feedback, so a series of movements are performed to calibrate the servos signals to the physical position of the arm. The calibration showed a good linear response between the control signal and servo angles. The calibration procedure also provided a transformation between the camera and arm coordinate systems. Inverse kinematic control was then used to position the arm. The range camera could also be used to identify objects in the scene. With the object location now known in the arm's coordinate system (transformed from the camera's coordinate system) the arm was able to move allowing it to grasp the object.
  • Item type:Publication,
    Multiple range imaging camera operation with minimal performance impact
    2010, SPIE
    Time-of-flight range imaging cameras operate by illuminating a scene with amplitude modulated light and measuring the phase shift of the modulation envelope between the emitted and reflected light. Object distance can then be calculated from this phase measurement. This approach does not work in multiple camera environments as the measured phase is corrupted by the illumination from other cameras. To minimize inaccuracies in multiple camera environments, replacing the traditional cyclic modulation with pseudo-noise amplitude modulation has been previously demonstrated. However, this technique effectively reduced the modulation frequency, therefore decreasing the distance measurement precision (which has a proportional relationship with the modulation frequency). A new modulation scheme using maximum length pseudo-random sequences binary phase encoded onto the existing cyclic amplitude modulation, is presented. The effective modulation frequency therefore remains unchanged, providing range measurements with high precision. The effectiveness of the new modulation scheme was verified using a custom time-of-flight camera based on the PMD19-K2 range imaging sensor. The new pseudo-noise modulation has no significant performance decrease in a single camera environment. In a two camera environment, the precision is only reduced by the increased photon shot noise from the second illumination source.