<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

University of Waikato Research

Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288

Browse

Search Results

Now showing 1 - 6 of 6
  • Item type:Publication,
    Integration of industrial solar and gaseous waste heat into heat recovery loops using constant and variable temperature storage
    2014, Elsevier
    Solar is a renewable energy that can be used to provide process heat to industrial sites but require thermal storage. HRLs (heat recovery loops) are an indirect method for transferring heat from one process to another using an intermediate fluid. With HRL's thermal storage is also necessary to effectively meet the stop/start time dependent nature of the multiple source and sink streams. Combining solar heating with HRL's is a cost effective way to share common storage and piping infrastructure. The conventional HRL design method based on a CTS (constant temperature storage) and a new HRL design method using VTS (variable temperature storage) are applied to demonstrate the potential benefits of inter-plant heat integration and installing solar heating. The dairy case study had available 12 source streams including four spray dryer exhausts and six sink streams. The addition of the dryer exhausts as heat sources was a critical factor in gaining a heat recovery of 10.8 MW for the variable temperature storage design, of which 5.1 MW was contributed from exhaust heat recovery. For the same minimum approach temperature the VTS approach achieved 37% more heat recovery compared to the CTS approach. Solar heating also proved to be a valuable source to be integrated into an HRL with a pinch around the cold storage tank with the maximum addition of 0.9 MW of heating on average for the CTS approach and 1.0 MW of heating on average for the VTS approach.
  • Item type:Publication,
    Fouling and pressure drop analysis of milk powder deposition on the front of parallel fins
    2013, Elsevier
    One method to reduce the energy consumption of industrial milk spray dryers is to recover waste heat from the exhaust dryer air. A significant challenge associated with this opportunity is the air contains a small amount of powder that may deposit on the face and surfaces of a recuperator. This paper introduces a novel lab based test that simulates powder deposition on a bank of parallel plate fins at exhaust dryer air conditions. The fin bank acts like the face of a typical finned tube row in a recuperator. The aim of this study is to look at how deposition on the front of fins is affected by the air conditions. Results show similar characteristics to other milk powder deposition studies that exhibit a dramatic increase in deposition once critical stickiness levels are reached. As powder deposits on the face of the fins, the pressure drop across the bank increases until eventually an asymptote occurs, at which point the rates of deposition and removal are similar. For very sticky conditions, deposition on the face of the fins can cause a rise in the pressure drop by as much as 65%. The pressure drop has also been successfully related to the percentage of open frontal area of the fins with and without deposition. Deposition inside and at the rear of the fin bank was found to be minimal.
  • Item type:Publication,
    Improving energy recovery in milk powder production through soft data optimisation
    2013, Elsevier
    Milk powder production is highly energy intensive and can benefit from the application of Pinch analysis techniques to develop better methods for integrating the process. In this study, process stream data is extracted from an industrial plant and Pinch analysis applied to calculate utility and heat recovery targets. Some of process data is also varied, within small ranges that do not harm product quality or violate environmental regulation, to minimise utility use targets. Using the Pinch design method and the targets as a guide, Maximum Energy Recovery (MER) networks are developed for two cases, where the condenser in the evaporator section of the plant may be directly or indirectly integrating into the reminder of the process. The two MER networks are compared to two heat exchanger network structures commonly found in industry. Results show that there is potential to increase specific heat recovery by over 30%, while reducing total cost by almost 10%, in the best case. To achieve maximum energy recovery, spray dryer exhaust air heat recovery is necessary and should be matched to preheat the dryer inlet air stream.
  • Item type:Publication,
    Methods for improving heat exchanger area distribution and storage temperature selection in heat recovery loops
    2013, Elsevier
    Inter-plant Heat Integration across a large site can be achieved using a HRL (Heat Recovery Loop). In this paper the interrelationship between HRL storage temperatures, heat recovery and total HRL exchanger area is investigated. A methodology for designing a HRL based on a ΔTmin approach is compared to three programming optimisation approaches where heat exchangers are constrained to have the same NTU (Number of Heat Transfer Units), LMTD (Log-Mean Temperature Difference) or to find the absolute MTA (Minimum Total Area) for a given heat recovery level. Analysis is performed using time-averaged and transient mass flow rate data and temperature data. The actual temperature driving force of the HRL heat exchangers is compared to the apparent driving force as indicated by the Composite Curves. Results for the same heat recovery level show that the ΔTmin approach is effective at minimising total area to within 5% of the minimum area approach. Allocation of individual heat exchanger areas can vary widely depending on the optimisation method, the characteristics of the transient stream data and the differences in the approach and exit stream temperatures. Results suggest that using the ΔTmin method for selecting storage temperatures in combination with sizing exchangers based on the time average CP values (for while the process is running) gives a near optimal solution without requiring lots of data input or computing resources
  • Item type:Publication,
    Process integration between individual plants at a large dairy factory by the application of heat recovery loops and transient stream analysis
    2012, Elsevier
    Indirect heat transfer between individual plants at a large industrial site, such as at a large dairy factory, can be accomplished using a Heat Recovery Loop (HRL) operating at relatively low temperatures (20–50 °C). Direct heat transfer between plants is problematic because of the production schedule and frequent process start-ups and shutdowns that occur due to the need for regular cleaning. The dynamic operation of an industrial HRL at a large dairy factory is presented and briefly discussed. A model HRL based on a set of variable industrial stream data is used to examine the effect of heat storage capacity and HRL temperature range on the amount of heat recovery. Both HRL temperature range and a small heat storage volume can significantly improve the amount of heat recovery. The interface level in the storage tank is also modelled for different volumes and the resulting system is very dynamic and therefore good control needs to be incorporated into the HRL.
  • Item type:Publication,
    Integration of solar thermal for improved energy efficiency in low-temperature-pinch industrial processes
    2010, Elsevier
    Solar thermal systems have the potential to provide renewable industrial process heat and are especially suited for low pinch temperature processes such as those in the food, beverage, and textile sectors. When correctly integrated within an industrial process, they can provide significant progress towards both increased energy efficiency and reduction in emissions. However, the integration of renewable solar energy into industrial processes presents a challenge for existing process integration techniques due to the non-continuous nature of the supply. A thorough pinch analysis study of the industrial process, taking in to account non-continuous operating rates, should be performed to evaluate the utility demand profile. Solar collector efficiency data under variable climatic conditions should also be collected for the specific site. A systematic method of combining this information leads to improved design and an optimal operating strategy. This approach has been applied to a New Zealand milk powder plant and benefits of several integration strategies, including mass integration, are investigated. The appropriate placement of the solar heat is analogous to the placement of a hot utility source and an energy penalty will be incurred when the solar thermal system provides heat below the pinch temperature.