University of Waikato Research
Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288
Browse
7 results
Search Results
Item type:Publication, Regularisation of neural networks by enforcing Lipschitz continuity2020, SpringerWe investigate the effect of explicitly enforcing the Lipschitz continuity of neural networks with respect to their inputs. To this end, we provide a simple technique for computing an upper bound to the Lipschitz constant—for multiple p-norms—of a feed forward neural network composed of commonly used layer types. Our technique is then used to formulate training a neural network with a bounded Lipschitz constant as a constrained optimisation problem that can be solved using projected stochastic gradient methods. Our evaluation study shows that the performance of the resulting models exceeds that of models trained with other common regularisers. We also provide evidence that the hyperparameters are intuitive to tune, demonstrate how the choice of norm for computing the Lipschitz constant impacts the resulting model, and show that the performance gains provided by our method are particularly noticeable when only a small amount of training data is available.Item type:Publication, Hidden features: Experiments with feature transfer for fine-grained multi-class and one-class image categorization2018, IEEECan we apply out-of-the box feature transfer using pre-trained convolutional neural networks in fine-grained multiclass image categorization tasks? What is the effect of (a) domainspecific fine-tuning and (b) a special-purpose network architecture designed and trained specifically for the target domain? How do these approaches perform in one-class classification? We investigate these questions by tackling two biological object recognition tasks: classification of “cryptic” plants of genus Coprosma and identification of New Zealand moth species. We compare results based on out-of-the-box features extracted using a pre-trained state-of-the-art network to those obtained by finetuning to the target domain, and also evaluate features learned using a simple Siamese network trained only on data from the target domain. For each extracted feature set, we test a number of classifiers, e.g., support vector machines. In addition to multiclass classification, we also consider one-class classification, a scenario that is particularly relevant to biosecurity applications. In the multi-class setting, we find that out-of-the-box lowlevel features extracted from the generic pre-trained network yield high accuracy (90.76%) when coupled with a simple LDA classifier. Fine-tuning improves accuracy only slightly (to 91.6%). Interestingly, features extracted from the much simpler Siamese network trained on data from the target domain lead to comparable results (90.8%). In the one-class classification setting, we note high variability in the area under the ROC curve across feature sets, opening up the possibility of considering an ensemble approach.Item type:Publication, Signal processing approaches for Jitter extraction in time-of-flight range imaging cameras2018, IEEEThe precision and accuracy of time-of-flight full-field range cameras are important for many applications, however there are a number of noise sources that degrade both precision and accuracy. Many of the noise sources such as nonlinearity, multipath inferences and harmonic cancellation are well investigated. Barely investigated is jitter on the camera light and shutter signals. Here we measure periodic and random jitter on the light signal of a camera. We use signal processing techniques to construct a reference signal, hence find the jitter. The performance of the proposed method is examined using the MESA Imaging SwissRanger 4000. We found periodic jitter of two frequencies at 0.12 and 5.04 MHz and the random jitter of 164 ± 4 ps, on the light signal of the camera.Item type:Publication, A strategy for the correction of effects of jitter in AMCW lidar images2013, IEEEFull-field range imaging cameras, which are an example of amplitude modulated continuous wave (AMCW) lidar, are subject to multiple error sources. In this paper we consider the possibility that a global jitter and/or drift occurs between the modulation signals to the active illumination source and the camera sensor. A model for jitter is presented and is used to characterise the jitter in a real camera system. Correction of the effects of jitter in real acquired range images is demonstrated by a reduction of the standard deviation of random noise by up to a factor of five, with the best reductions occurring in pixels that receive a strong signal.Item type:Publication, Application of lidar techniques to time-of-flight range imaging2015, OPTICAL SOC AMERAmplitude modulated continuous wave (AMCW) time-of flight (ToF) range imaging cameras measure distance by illuminating the scene with amplitude modulated light and measuring the phase difference between the transmitted and reflected modulation envelope. This method of optical range measurement suffers from errors caused by multiple propagation paths, motion, phase wrapping and non-ideal amplitude modulation. In this paper a ToF camera is modified to operate in modes analogous to continuous wave (CW) and stepped frequency continuous wave (SFCW) lidar. In CW operation the velocity of objects can be measured. CW measurement of velocity was linear with true velocity (R² = 0.9969). Qualitative analysis of a complex scene confirms that range measured by SFCW is resilient to errors caused by multiple propagation paths, phase wrapping and non-ideal amplitude modulation which plague AMCW operation. In viewing a complicated scene through a translucent sheet, quantitative comparison of AMCW with SFCW demonstrated a reduction in the median error from −1.3 m to −0.06 m with inter-quartile range of error reduced from 4.0 m to 0.18 m.Item type:Publication, Extracting the MESA SR4000 Calibrations2015, SPIETime-of-flight range imaging cameras are capable of acquiring depth images of a scene. Some algorithms require these cameras to be run in `raw mode', where any calibrations from the off-the-shelf manufacturers are lost. The calibration of the MESA SR4000 is herein investigated, with an attempt to reconstruct the full calibration. Possession of the factory calibration enables calibrated data to be acquired and manipulated even in “raw mode.” This work is motivated by the problem of motion correction, in which the calibration must be separated into component parts to be applied at different stages in the algorithm. There are also other applications, in which multiple frequencies are required, such as multipath interference correction. The other frequencies can be calibrated in a similar way, using the factory calibration as a base. A novel technique for capturing the calibration data is described; a retro-reflector is used on a moving platform, which acts as a point source at a distance, resulting in planar waves on the sensor. A number of calibrations are retrieved from the camera, and are then modelled and compared to the factory calibration. When comparing the factory calibration to both the “raw mode” data, and the calibration described herein, a root mean squared error improvement of 51:3mm was seen, with a standard deviation improvement of 34:9mm. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.Item type:Publication, Design of a Pseudo-Holographic Distributed Time-of-Flight Sonar Range-Imaging System2016, IEEEThe design of an audible sonar distributed sensor time-of-flight range imaging system is investigated, sonar being chosen as a substitute for optical range imaging due to cost and simplicity of implementation. The distributed range imaging system proposed is based on the holographic principle where the sensors detect the self interference of the reflected sound from the scene, and the Fourier analysis computes the reflected object profile. An approximate linearised model used in related holographic imaging techniques is found to be inappropriate for the design, and qualitative assessment of simulations show that removing the linearisation dramatically improves image reconstruction. Quantitatively the nonlinear reconstruction improves the RMSE by a factor of 1.3-2.1 times. The full nonlinear reconstruction is slow, and mathematical development lead to 15 fold reduction in computation time.