<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

University of Waikato Research

Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288

Browse

Search Results

Now showing 1 - 2 of 2
  • Item type:Publication,
    Running kinematics, spatiotemporal variation and lower limb strength at different stages of a 156-km ultra-trail race
    2026-02, Edizioni Minerva Medica
    BACKGROUND: Ultra-trail running is increasingly popular, yet most research on biomechanics focuses on road running or treadmills. This study assesses changes in foot strike pattern (FSP), step frequency, and other biomechanical parameters over a 156-km ultra-trail race. METHODS: Fifty-five experienced runners participated in the Trail Scientifique de Clécy, a 156-km race with 6000 meters of elevation gain. Biomechanical data were collected at the end of each 26-km lap using video for FSP and Optojump for other parameters. Muscle strength was measured via maximal voluntary isometric contraction (MVIC) of the hip abductors and ankle plantar flexors. RESULTS: Forty-one runners completed the race. FSP remained consistent. Step frequency decreased initially (P=0.003) before stabilizing. Self-selected speed declined by 14.2% (P<0.001), and step length reduced by 12.6% (P<0.001). Ground contact time increased (+12.9%, P<0.001), while flight time remained stable. Leg stiffness showed a non-significant decreasing trend (P=0.048). MVIC for hip abductors and ankle plantar flexors slightly decreased late in the race (P=0.015 and P=0.004). CONCLUSIONS: Experienced ultra-trail runners maintain consistent FSP while strategically adapting other biomechanical parameters to manage fatigue, supporting sustained performance and injury prevention in ultra-endurance races.
  • Item type:Publication,
    Biomechanics and subjective measures of recreational male runners in three shoes running outdoors: A randomised crossover study
    2023, Taylor & Francis
    We compared biomechanical and subjective data from outdoor running in: habitual (OWN), Saucony Endorphin Racer 2 minimal (FLAT) and Nike Vaporfly 4% (VP4) shoes. We also explored relationships between comfort measures and the collected data. Eighteen male recreational runners ran three 1.5-km trials outdoors, once per shoe. The first 1.1 km was run at a self-selected comfortable (slower) speed, and last 400 m at perceived 5-km race pace (faster). A GPS-enabled smartwatch, 15-m Optojump system, high-speed camera and tibial accelerometer collected biomechanical data. Subjective data on comfort, shoe properties and overall running experience were collected using visual analogue scales (VAS) and rankings. Cadence, leg stiffness and vertical stiffness were greater in FLAT than both OWN and VP4 at the slower speed (trivial to small ES). At both speeds, footstrike angles were smaller in FLAT (small to large ES), while propulsion phase was shorter in VP4 (moderate to large ES). FLAT was ranked as the least comfortable at the slower speed and most likely to cause injury, whereas OWN as the most comfortable and least likely to cause injury. Comfort was not significantly different at the faster speed between shoes. Comfort measures were more strongly correlated to subjective than biomechanical data. The two experimental shoes generally had non-significant or small effects on running biomechanics versus OWN. As VP4 are more like traditional than minimal shoes, these were perceived as more comfortable. Running speed appeared to affect subjective measures. Speed should be considered when prescribing and selecting shoes.