<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

University of Waikato Research

Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288

Browse

Search Results

Now showing 1 - 5 of 5
  • Item type:Publication,
    Running kinematics, spatiotemporal variation and lower limb strength at different stages of a 156-km ultra-trail race
    2026-02, Edizioni Minerva Medica
    BACKGROUND: Ultra-trail running is increasingly popular, yet most research on biomechanics focuses on road running or treadmills. This study assesses changes in foot strike pattern (FSP), step frequency, and other biomechanical parameters over a 156-km ultra-trail race. METHODS: Fifty-five experienced runners participated in the Trail Scientifique de Clécy, a 156-km race with 6000 meters of elevation gain. Biomechanical data were collected at the end of each 26-km lap using video for FSP and Optojump for other parameters. Muscle strength was measured via maximal voluntary isometric contraction (MVIC) of the hip abductors and ankle plantar flexors. RESULTS: Forty-one runners completed the race. FSP remained consistent. Step frequency decreased initially (P=0.003) before stabilizing. Self-selected speed declined by 14.2% (P<0.001), and step length reduced by 12.6% (P<0.001). Ground contact time increased (+12.9%, P<0.001), while flight time remained stable. Leg stiffness showed a non-significant decreasing trend (P=0.048). MVIC for hip abductors and ankle plantar flexors slightly decreased late in the race (P=0.015 and P=0.004). CONCLUSIONS: Experienced ultra-trail runners maintain consistent FSP while strategically adapting other biomechanical parameters to manage fatigue, supporting sustained performance and injury prevention in ultra-endurance races.
  • Item type:Publication,
    Biomechanics and subjective measures of recreational male runners in three shoes running outdoors: A randomised crossover study
    2023, Taylor & Francis
    We compared biomechanical and subjective data from outdoor running in: habitual (OWN), Saucony Endorphin Racer 2 minimal (FLAT) and Nike Vaporfly 4% (VP4) shoes. We also explored relationships between comfort measures and the collected data. Eighteen male recreational runners ran three 1.5-km trials outdoors, once per shoe. The first 1.1 km was run at a self-selected comfortable (slower) speed, and last 400 m at perceived 5-km race pace (faster). A GPS-enabled smartwatch, 15-m Optojump system, high-speed camera and tibial accelerometer collected biomechanical data. Subjective data on comfort, shoe properties and overall running experience were collected using visual analogue scales (VAS) and rankings. Cadence, leg stiffness and vertical stiffness were greater in FLAT than both OWN and VP4 at the slower speed (trivial to small ES). At both speeds, footstrike angles were smaller in FLAT (small to large ES), while propulsion phase was shorter in VP4 (moderate to large ES). FLAT was ranked as the least comfortable at the slower speed and most likely to cause injury, whereas OWN as the most comfortable and least likely to cause injury. Comfort was not significantly different at the faster speed between shoes. Comfort measures were more strongly correlated to subjective than biomechanical data. The two experimental shoes generally had non-significant or small effects on running biomechanics versus OWN. As VP4 are more like traditional than minimal shoes, these were perceived as more comfortable. Running speed appeared to affect subjective measures. Speed should be considered when prescribing and selecting shoes.
  • Item type:Publication,
    Kinematics of recreational male runners in "super", minimalist and habitual shoes
    2022-06-14, Taylor & Francis
    We conducted an exploratory analysis to compare running kinematics of 16 male recreational runners wearing Nike Vaporfly 4% (VP4), Saucony Endorphin racing flat (FLAT), and their habitual (OWN) footwear. We also explored potential relationships between kinematic and physiological changes. Runners (age: 33 ± 12 y, V _O2peak: 55.2 ± 4.3 ml · kg−1·min−1) attended 3 sessions after completing an V _ O2peak test in which sagittal plane 3D kinematics at submaximal running speeds (60%, 70% and 80% ʋ V _ O2peak) were collected alongside economy measures. Kinematics were compared using notched boxplots, and between-shoe kinematic differences were plotted against between-shoe economy differences. Across intensities, VP4 involved longer flight times (6.7 to 10.0 ms) and lower stance hip range of motion (~3°), and greater vertical pelvis displacement than FLAT (~0.4 cm). Peak dorsiflexion angles (~2°), ankle range of motion (1.0° to 3.9°), and plantarflexion velocities (11.3 to 89.0 deg · sec−1) were greatest in FLAT and lowest in VP4. Foot-ground angles were smaller in FLAT (2.5° to 3.6°). Select kinematic variables were moderately related to economy, with higher step frequencies and longer step lengths in VP4 and FLAT associated with improved economy versus OWN. Footwear changes from OWN altered running kinematics. The most pronounced differences were observed in ankle, spatiotemporal, and foot-ground angle variables.
  • Item type:Publication,
    Metabolic and performance responses of male runners wearing 3 types of footwear: Nike Vaporfly 4%, Saucony Endorphin racing flats, and their own shoes
    2022, Elsevier
    Purpose We compared running economy (RE) and 3-km time-trial (TT) variables of runners wearing Nike Vaporfly 4% (VP4), Saucony Endorphin lightweight racing flats (FLAT), and their habitual running (OWN) footwear. Methods Eighteen male recreational runners (age = 33.5 ± 11.9 year (mean ± SD), peak oxygen uptake (VO2peak) = 55.8 ± 4.4 mL/kg·min) attended 4 sessions approximately 7 days apart. The first session consisted of a VO2peak test to inform subsequent RE speeds set at 60%, 70%, and 80% of the speed eliciting VO2peak. In subsequent sessions, treadmill RE and 3-km TTs were assessed in the 3 footwear conditions in a randomized, counterbalanced crossover design. Results Oxygen consumption (mL/kg·min) was less in VP4 (from 4.3% to 4.4%, p ≤ 0.002) and FLAT (from 2.7% to 3.4%, p ≤ 0.092) vs. OWN across intensities, with a non-significant difference between VP4 and FLAT (1.0%–1.7%, p ≥ 0.292). Findings related to energy cost (W/kg) and energetics cost of transport (J/kg·m) were comparable. VP4 3-km TT performance (11:07.6 ± 0:56.6 mm:ss) was enhanced vs. OWN by 16.6 s (2.4%, p = 0.005) and vs. FLAT by 13.0 s (1.8%, p = 0.032). The 3-km times between OWN and FLAT (0.5%, p = 0.747) were similar. Most runners (n = 11, 61%) ran their fastest TT in VP4. Conclusion Overall, VP4 improved laboratory-based RE measures in male recreational runners at relative speeds compared to OWN, but the RE improvements in VP4 were not significant vs. FLAT. More runners exhibited better treadmill TT performances in VP4 (61%) vs. FLAT (22%) and OWN (17%). The variability in RE (–10.3% to 13.3%) and TT (–4.7% to 9.3%) improvements suggests that responses to different types of shoes are individualized and warrant further investigation.
  • Item type:Publication,
    Evidence of variable performance responses to the Nike 4% shoe: Definitely not a game-changer for all recreational runners
    2020, Center for Open Science
    Purpose: We compared running economy (RE) and 3-km time-trial (TT) performances of male recreational runners wearing the Nike Vaporfly 4% (NIKE), lightweight racing flats (FLAT), and their habitual footwear (OWN). Methods: Eighteen male recreational runners [age: 33.5 (11.9) y, V̇O2peak: 55.8 (4.4) mL·kg-1·min-1] attended 4 sessions ~7 days apart. The first session consisted of a V̇O2peak test to inform subsequent RE speeds set at 60, 70, and 80% of the speed eliciting V̇O2peak. In subsequent sessions, treadmill RE and 3-km TT were assessed in the three footwear in a randomised, counterbalanced crossover design. Results: RE was improved in NIKE (3.6 to 4.5%, p ≤ 0.002) and FLAT (2.4 to 4.0%, p ≤ 0.042) versus OWN across intensities, with a trivial difference between NIKE and FLAT (1.0 to 1.6%, p ≥ 0.325). NIKE 3-km TT (11:07.6 ± 0:56.6 mm:ss) was superior to OWN by 16.6 s (2.4%, p = 0.005) and FLAT by 13.0 s (1.8%, , p = 0.032), with similar times between OWN and FLAT (0.5%, , p = 0.747). Only 29% of runners were more economical across intensities and faster in NIKE. Conclusions: Overall, our findings indicate that NIKE could benefit RE in male recreational runners at relative speeds when compared to OWN, but not when compared to FLAT. More runners exhibited better TT performances in NIKE (61%) versus FLAT (22%) and OWN (17%). The high variability in individual RE (-3.1 to 12.1%) and TT (-3.8 to 8.2%) shoe-responses suggests that individualisation of running footwear prescription is warranted.