<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

University of Waikato Research

Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288

Browse

Search Results

Now showing 1 - 5 of 5
  • Item type:Publication,
    Closed-form inverses for the mixed pixel/multipath interference problem in AMCW lidar
    2012, SPIE
    We present two new closed-form methods for mixed pixel/multipath interference separation in AMCW lidar systems. The mixed pixel/multipath interference problem arises from the violation of a standard range-imaging assumption that each pixel integrates over only a single, discrete backscattering source. While a numerical inversion method has previously been proposed, no close-form inverses have previously been posited. The first new method models reflectivity as a Cauchy distribution over range and uses four measurements at different modulation frequencies to determine the amplitude, phase and reflectivity distribution of up to two component returns within each pixel. The second new method uses attenuation ratios to determine the amplitude and phase of up to two component returns within each pixel. The methods are tested on both simulated and real data and shown to produce a significant improvement in overall error. While this paper focusses on the AMCW mixed pixel/multipath interference problem, the algorithms contained herein have applicability to the reconstruction of a sparse one dimensional signal from an extremely limited number of discrete samples of its Fourier transform.
  • Item type:Publication,
    Understanding and ameliorating non-linear phase and amplitude responses in AMCW Lidar
    2012, MDPI
    Amplitude modulated continuous wave (AMCW) lidar systems commonly suffer from non-linear phase and amplitude responses due to a number of known factors such as aliasing and multipath inteference. In order to produce useful range and intensity information it is necessary to remove these perturbations from the measurements. We review the known causes of non-linearity, namely aliasing, temporal variation in correlation waveform shape and mixed pixels/multipath inteference. We also introduce other sources of non-linearity, including crosstalk, modulation waveform envelope decay and non-circularly symmetric noise statistics, that have been ignored in the literature. An experimental study is conducted to evaluate techniques for mitigation of non-linearity, and it is found that harmonic cancellation provides a significant improvement in phase and amplitude linearity.
  • Item type:Publication,
    Blind deconvolution of depth-of-field limited full-field lidar data by determination of focal parameters
    2010, Society of Photo-Optical Instrumentation Engineers
    We present a new two-stage method for parametric spatially variant blind deconvolution of full-field Amplitude Modulated Continuous Wave lidar image pairs taken at different aperture settings subject to limited depth of field. A Maximum Likelihood based focal parameter determination algorithm uses range information to reblur the image taken with a smaller aperture size to match the large aperture image. This allows estimation of focal parameters without prior calibration of the optical setup and produces blur estimates which have better spatial resolution and less noise than previous depth from defocus (DFD) blur measurement algorithms. We compare blur estimates from the focal parameter determination method to those from Pentland's DFD method, Subbarao's S-Transform method and estimates from range data/the sampled point spread function. In a second stage the estimated focal parameters are applied to deconvolution of total integrated intensity lidar images improving depth of field. We give an example of application to complex domain lidar images and discuss the trade-off between recovered amplitude texture and sharp range estimates.
  • Item type:Publication,
    Mixed pixel return separation for a full-field ranger
    2008
    Full-field amplitude modulated continuous wave range imagers commonly suffer from the mixed pixel problem. This problem is caused by the integration of light from multiple sources by a single pixel, particularly around the edges of objects, resulting in erroneous range measurements. In this paper we present a method for identifying the intensity and range of multiple return values within each pixel, using the harmonic content of the heterodyne beat waveform. Systems capable of measurements at less than 90 degree phase shifts can apply these methods. Our paper builds on previous simulation based work and uses real range data. The method involves the application of the Levy-Fullagar algorithm and the use of the cyclic nature of the beat waveform to extract the mean noise power. We show that this method enables the separation of multiple range sources and also decreases overall ranging error by 30% in the single return case. Error in the two return case was found to increase substantially as relative intensity of the return decreased.
  • Item type:Publication,
    Multiple return separation for a full-field ranger via continuous waveform modelling
    2009, SPIE and IS&T
    We present two novel Poisson noise Maximum Likelihood based methods for identifying the individual returns within mixed pixels for Amplitude Modulated Continuous Wave rangers. These methods use the convolutional relationship between signal returns and the recorded data to determine the number, range and intensity of returns within a pixel. One method relies on a continuous piecewise truncated-triangle model for the beat waveform and the other on linear interpolation between translated versions of a sampled waveform. In the single return case both methods provide an improvement in ranging precision over standard Fourier transform based methods and a decrease in overall error in almost every case. We find that it is possible to discriminate between two light sources within a pixel, but local minima and scattered light have a significant impact on ranging precision. Discrimination of two returns requires the ability to take samples at less than 90 phase shifts.