University of Waikato Research
Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288
Browse
12 results
Search Results
Item type:Publication, Reporting guidelines for running biomechanics and footwear studies using three-dimensional motion capture2023, Taylor & FrancisRunning shoes act as an interface between the foot and the ground and play a central role in running. Running shoes are constantly evolving, as is the research on running biomechanics and footwear. Experts agree that comfort, injury prevention, and performance are important factors to consider in the design and manufacturing of running footwear; however, these topics are often complex to investigate due to their multifactorial, individualised, or subjective nature with no clear evidence-based direction for footwear prescription.Item type:Publication, Patient-reported outcome measure comparison of two cemented primary total hip arthroplasty implant combinations for osteoarthritis: A regional New Zealand study2026-04-02, SpringerPurpose Compare patient-reported outcome measures (PROMs) of two cemented implants in primary total hip arthroplasty (THA) for osteoarthritis in a New Zealand regional joint registry. Identify patient predictors of poorer PROMs. Methods We analysed observational data from primary THA surgeries for osteoarthritis performed between 1 January 2003 and 30 June 2023, with at least one recorded PROM (n = 1365) from a regional joint registry. We compared preoperative, 1-year, 5-year, and 10-year PROMs in the cemented, highly crosslinked polyethylene Exeter® X3 Rimfit cup (Rimfit) and its conventional polyethylene predecessor, the Exeter® Contemporary Flanged cup (ECF) with the same cemented Exeter® V40 stem. We investigated six patient factors and their influence on physical function, and mental and physical health PROMs. Results No significant difference in physical function PROMs were noted between implants at any timepoint. Both implant combinations exhibited excellent (> 41) mean postoperative Oxford hip scores based on published thresholds (Rimfit: mean 41.30 ± SD 8.46; ECF: mean 41.64 ± SD 8.67). Mental health was significantly better preoperatively and at 1-year and 5-year with the Rimfit based on Veterans RAND 12-Item Health Survey. Public funding was a significant and clinically meaningful predictor of poorer preoperative outcomes in all PROMs and in both cohorts, followed by comorbidity status. The strongest significant predictor of poorer postoperative PROMs was poorer preoperative PROMs, followed by Māori ethnicity. Conclusion Both implant combinations demonstrated similar PROMs up to 10 years, but the Rimfit exhibited superior mental health. Public funding, comorbidity status, and Māori ethnicity were predictors of statistically significant and clinically meaningful poorer preoperative and postoperative PROMs.Item type:Publication, 10-year survival comparison of two cemented implants in primary total hip arthroplasty for osteoarthritis: A New Zealand regional study2025, SpringerIntroduction Compare 10-year survival of the cemented highly crosslinked polyethylene Exeter® Rimfit™ (Rimfit) Cup and its predecessor, the ultra-high molecular weight polyethylene Exeter® Contemporary Flanged Cup™ (ECF), both with an Exeter® V40™ stem, in primary total hip arthroplasty (THA) for osteoarthritis in the Bay of Plenty region of NZ. Method We extracted national registry data for THA surgeries in the region between 1 January 2003 and 30 June 2023 and report the 10-year survival and reasons for revision of the two fully cemented implants (n = 495). We compared standard Kaplan-Meier estimates using the log-rank test. Cox proportional hazard models investigated the potential influence of six patient variables on the survival of each implant: sex, age, body mass index (BMI), ethnicity, American Society of Anesthesiologists (ASA) rating, and funding source (public/private). Results No statistically significant difference in 10-year survival rate between the implants (p = 0.334) (ECF 95.6% [93.4, 97.9], Rimfit 97.0% [95.9, 98.2]) or statistically significant difference in revision reasons between the implants (p = 0.09) was noted. Cox regression revealed no statistically significant influence of any of the six patient variables on the 10-year survival of the ECF (p = 0.584) or Rimfit (p = 0.611). Conclusion Both implants exceeded 95% survival at 10-years, which is favourable compared to the corresponding 94.8% national survivorship of cemented implants in NZ. There is no statistically significant difference in the 10-year survival rate or reasons for revision of the two cemented implants compared in this region. The Rimfit appears a suitable alternative to the ECF, from a survival and revision perspective.Item type:Publication, 15-year patient-reported outcomes of a cemented flanged cup and stem combination in primary total hip arthroplasty: A New Zealand study2026, SAGEMethods: We investigated 15-year patient-reported outcomes (PROMs) and their predictors in primary total hip arthroplasty (THA) for osteoarthritis using a cemented flanged cup and stem from a regional joint registry in New Zealand. Regional data were collected for all primary THAs with this cemented combination from 1 January 2003 to 30 June 2023 who had recorded PROMs on at least 1 occasion (n = 263). PROMs included Oxford Hip Score, Western Ontario and McMaster Universities Arthritis Index and Veterans Rand-12, evaluated against patient age, ethnicity, sex, body mass index (BMI), funding pathway, and American Society of Anesthesiologists (ASA) rating. Results: Significant improvements across preoperative PROMs were noted 1-year post-surgery, with a mean change above 23 in the Oxford Hip Score maintained at 5, 10, and 15 years (p ⩽ 0.001). Conclusions: Regression analysis indicated that being female, public funding, and higher BMI were associated with worse preoperative PROMs. Poorer preoperative scores, older age and ASA 3 rating correlated with poorer postoperative outcomes.Item type:Publication, Exploring the reliability of isometric benchmark tests and their relationship to performance characteristics in elite track sprint cyclists2025, Taylor & FrancisBenchmark tests in competitive cycling identify talent, individualise training, and monitor performance. However, varying protocols often produce conflicting results, reducing comparability. Isometric tests are prevalent, but reliability and performance correlation are underexplored. Determine the test–retest reliability of benchmark test metrics in elite track sprint cyclists and their relationship to a performance outcome. Nineteen elite track sprint cyclists (12 males, 7 females) completed seven benchmark tests across two days: modified sit-and-reach; on-bike rolling seated maximum 6-s sprints; 3-s bilateral on-bike isometrics at 90° crank angle; 3-s prone bench pull isometrics; 3-s lumbar extension isometrics; 3-s seated off-bike isometrics; and modified plank endurance. For the performance outcome, a third session within 7 days assessed peak power using an inertial load cycle ergometer. All tests showed excellent measurement consistency (ICC<inf>3,1</inf> ≥ 0.92), with low systematic bias (p ≥ 0.063), though confidence interval varied due to modest sample size. High test–retest reliability was supported by low typical errors (CV 2.0–5.5%; 9.6% for endurance). Nine benchmark metrics, including bilateral isometric measures, showed moderate to excellent correlation with peak power output (r = 0.52–0.94, p ≤ 0.023); six remained statistically significant after Bonferroni correction (p ≤ 0.005). All benchmark metrics were reliable, with six strongly and statistically significantly associated with performance.Item type:Publication, Outcomes of cemented and hybrid primary total hip arthroplasty for osteoarthritis: A systematic review with narrative synthesis2025, SpringerPurpose To compare primary (implant survival and periprosthetic fracture rates, PPF) and secondary (patient reported outcome measures, PROMs) outcomes of cemented and hybrid primary total hip arthroplasty (THA) for osteoarthritis. Methods Four databases (PubMed®, EBSCO, ScienceDirect®, and Scopus®) were searched (1 October 2023 and 15 November 2024) for original studies comparing cemented and hybrid primary THA for osteoarthritis. survival, PPF rates, and PROMs. Included studies were assessed for risk of bias using the Quality in Prognostic Studies or RoB 2.0 tool, critically appraised for strength of evidence using GRADE, and underwent a narrative synthesis. PROSPERO registration number CRD42023462884. Results Eight studies met criteria for review (n = 357,748). Risk of bias was high for two, moderate for three, and low for three studies. Quality of evidence was very low for both primary and secondary outcomes. Five studies met the criteria for the primary outcome (survival) (n = 257,756), two PPF rates (n = 29,581), and three PROMs (n = 382). Three of five studies reported hybrid survival as not significantly different to cemented, and two identified cemented as superior. The three PROMs studies reported no difference between cemented and hybrid THA. A lack of studies and comparative data made it unfeasible to determine PPF outcomes. Conclusion Few high-quality studies and methodological heterogeneity led to moderate to high bias and very low overall evidence certainty. Eligible studies indicated no difference in short to medium term PROMs or 10-year survival between the two fixations. Long-term studies indicated superior cemented survival outcomes. A substantial gap in long-term PROMs and PPF rates is noted.Item type:Publication, No significant links between somatognosia, stereognosia, and hypermobility: sensory processing unlikely to drive common complaints in hypermobile population2025, BMCBackground: Previous research has demonstrated impaired proprioception and poorer responses to tactile deep pressure, visual-tactile integration, and vestibular stimuli in individuals with generalized hypermobility, potentially leading to sensory processing issues. Therefore, we aimed to explore the influence of hypermobility on somatognosia and stereognosia. Methods: Forty-six participants were assessed using the Beighton score and categorized into three groups: non-hypermobile (n = 20), symptomatic hypermobile (n = 13), and asymptomatic hypermobile (n = 13). Somatognosia was evaluated using the shoulder width test in the vertical plane and pelvic width test in the vertical and horizontal planes. Stereognosia was assessed with Petrie’s test. Spearman’s rank correlation coefficient was examined the relationship between the Beighton score and measures of somatognosia and stereognosia. An unpaired t-test was used to compare variables between hypermobile (both symptomatic and asymptomatic) and non-hypermobile individuals, while a one-way ANOVA was used to compare data between the three groups. Results: No significant relationship was observed between Beighton scores and measures of somatognosia and stereognosia. The t-test revealed no statistically significant differences between hypermobile and non-hypermobile groups in the shoulder width, two pelvic widths, and Petrie’s tests (all p ≥ 0.105). Similarly, one-way ANOVA showed no statistically significant differences between the three groups across these tests (all p ≥ 0.177). Conclusions: The results indicate that somatognosia and stereognosia are not significantly related to the Beighton score and do not significantly differ between the groups studied. These sensory processing functions are unlikely to contribute to the common complaints reported by hypermobile individuals. Clinical trial number: Not applicable.Item type:Publication, Letter to the Editor concerning ‘The Calf Raise App shows good concurrent validity compared with a linear encoder in measuring total concentric work’: Let's not compare apples to oranges2025, WileyThe authors state that this study was designed as a validity study, yet it appears to be an add‐on to another prospectively registered study (NCT05323773) with no initial intention of concurrent validation of the Calf Raise App. To properly assess the validity of the systems, similar reference points (e.g., the lateral side of the foot) should be used, and outcomes should be compared to a gold standard, such as 3D motion analysis.Item type:Publication, Looking beyond the number of repetitions: An observational cross-sectional study on calf raise test outcomes in children aged 10–17 years2024-09-23, Taylor & FrancisAims: The calf raise test (CRT) assesses plantarflexor strength and endurance, but normative data for children are scarce. Furthermore, contradictions exist on which factors are associated with total repetitions, with repetitions being the only metric considered. We quantified three of the main CRT outcomes (repetitions, total work, and peak height) in children 10–17 years and explored their relationship with various factors. Methods: Healthy children (n = 165, 50.3% female) completed single-legged calf raises on a 10° incline, once on each leg. Test outcomes were extracted using the valid and reliable Calf Raise application. Results: CRT outcomes were not significantly different between legs (p ≥ .19). The only covariates significantly associated with outcomes based on stepwise quantile regressions were body mass index centile for repetitions, meeting physical activity recommendations for total work and peak height, and age for total work. Outcomes did not significantly differ based on sex or maturation. Median values were around 26 for repetitions, 640–1460 J for total work (age dependent), and 10.1 cm for peak height for children meeting physical activity recommendations. Conclusion: Children who were older, had lower body mass indices, and were more active exhibited superior CRT outcomes. Meeting physical activity recommendations appears beneficial for plantarflexor function and should continue to be prioritized in children.Item type:Publication, Normative values for calf muscle strength-endurance in the general population assessed with the Calf Raise Application: A large international cross-sectional study2025-05-01, ElsevierBackground: Calf muscle strength-endurance can be reliably assessed with the Heel Rise Endurance Test (HRET), but normative values are lacking. Objectives: To establish normative values for calf muscle strength-endurance, adjusted for personal characteristics. Methods: 500 individuals without current/previous symptoms of Achilles tendinopathy or recent lower limb immobilization were included. Primary outcome measures were the number of repetitions, total work (J), total vertical displacement (cm), and peak height (cm) upon the single-leg HRET, assessed using the validated Calf Raise Application. A multiple quantile regression model was developed, incorporating covariates (personal characteristics) which significantly impacted HRET metrics. Median (50.0th percentile) and 95 % reference intervals (2.5th-97.5th percentiles) were derived. Results: 55 % of the participants were female and 88 % participated in physical activities. Median (dominant/non-dominant leg) number of repetitions was 25/24, total work was 1374/1325 J, vertical displacement was 192/186 cm, and peak height was 9.3/9.6 cm. There was no significant difference between the dominant and non-dominant leg for any HRET metric. Lower physical activity levels, female sex, and higher body mass index (BMI) were associated with lower HRET metrics. Conclusions: Normative calf muscle strength-endurance metrics (number of repetitions, total work, total displacement, and peak height) were developed. Personal characteristics influence HRET outcomes, with female sex, higher BMI, and lower physical activity levels being associated with lower HRET metrics. An openly accessible calculator for estimating normative HRET metrics was developed to help healthcare providers monitor personalized recovery trajectories and provide well-informed rehabilitation guidance. Documenting HRET metrics beyond repetition count may aid in assessing impairment severity and evaluating calf muscle function.