<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

University of Waikato Research

Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288

Browse

Search Results

Now showing 1 - 2 of 2
  • Item type:Publication,
    Patient-reported outcome measure comparison of two cemented primary total hip arthroplasty implant combinations for osteoarthritis: A regional New Zealand study
    2026-04-02, Springer
    Purpose Compare patient-reported outcome measures (PROMs) of two cemented implants in primary total hip arthroplasty (THA) for osteoarthritis in a New Zealand regional joint registry. Identify patient predictors of poorer PROMs. Methods We analysed observational data from primary THA surgeries for osteoarthritis performed between 1 January 2003 and 30 June 2023, with at least one recorded PROM (n = 1365) from a regional joint registry. We compared preoperative, 1-year, 5-year, and 10-year PROMs in the cemented, highly crosslinked polyethylene Exeter® X3 Rimfit cup (Rimfit) and its conventional polyethylene predecessor, the Exeter® Contemporary Flanged cup (ECF) with the same cemented Exeter® V40 stem. We investigated six patient factors and their influence on physical function, and mental and physical health PROMs. Results No significant difference in physical function PROMs were noted between implants at any timepoint. Both implant combinations exhibited excellent (> 41) mean postoperative Oxford hip scores based on published thresholds (Rimfit: mean 41.30 ± SD 8.46; ECF: mean 41.64 ± SD 8.67). Mental health was significantly better preoperatively and at 1-year and 5-year with the Rimfit based on Veterans RAND 12-Item Health Survey. Public funding was a significant and clinically meaningful predictor of poorer preoperative outcomes in all PROMs and in both cohorts, followed by comorbidity status. The strongest significant predictor of poorer postoperative PROMs was poorer preoperative PROMs, followed by Māori ethnicity. Conclusion Both implant combinations demonstrated similar PROMs up to 10 years, but the Rimfit exhibited superior mental health. Public funding, comorbidity status, and Māori ethnicity were predictors of statistically significant and clinically meaningful poorer preoperative and postoperative PROMs.
  • Item type:Publication,
    10-year survival comparison of two cemented implants in primary total hip arthroplasty for osteoarthritis: A New Zealand regional study
    2025, Springer
    Introduction Compare 10-year survival of the cemented highly crosslinked polyethylene Exeter® Rimfit™ (Rimfit) Cup and its predecessor, the ultra-high molecular weight polyethylene Exeter® Contemporary Flanged Cup™ (ECF), both with an Exeter® V40™ stem, in primary total hip arthroplasty (THA) for osteoarthritis in the Bay of Plenty region of NZ. Method We extracted national registry data for THA surgeries in the region between 1 January 2003 and 30 June 2023 and report the 10-year survival and reasons for revision of the two fully cemented implants (n = 495). We compared standard Kaplan-Meier estimates using the log-rank test. Cox proportional hazard models investigated the potential influence of six patient variables on the survival of each implant: sex, age, body mass index (BMI), ethnicity, American Society of Anesthesiologists (ASA) rating, and funding source (public/private). Results No statistically significant difference in 10-year survival rate between the implants (p = 0.334) (ECF 95.6% [93.4, 97.9], Rimfit 97.0% [95.9, 98.2]) or statistically significant difference in revision reasons between the implants (p = 0.09) was noted. Cox regression revealed no statistically significant influence of any of the six patient variables on the 10-year survival of the ECF (p = 0.584) or Rimfit (p = 0.611). Conclusion Both implants exceeded 95% survival at 10-years, which is favourable compared to the corresponding 94.8% national survivorship of cemented implants in NZ. There is no statistically significant difference in the 10-year survival rate or reasons for revision of the two cemented implants compared in this region. The Rimfit appears a suitable alternative to the ECF, from a survival and revision perspective.