University of Waikato Research
Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288
Browse
3 results
Search Results
Item type:Publication, Supercapacitor assisted multilevel inverter topology for off-grid renewable energy systems2024, IEEESupercapacitor assisted (SCA) techniques are a new family of power electronic building blocks for renewable energy systems based on the theory published as SCA-loss management (SCALoM) concept. SCA inverter is a unique application of SCALoM theory, capable of meeting any capacity of off-grid inverter requirement, based on a combination of an even number of smaller inverters with suitably sized supercapacitor banks. SCA-inverter technique reduces input loop losses and transistor voltage stresses while providing DC-UPS capability without using batteries. This paper discusses the technical background of the SCA-inverter arrangement of operating seamlessly without common load balancing issues observed in other multi-inverter systems and techniques. The experiment results of two/four-SCA-inverter arrangement show stable operation of the inverter systems, both in switching transients of the supercapacitor banks and steady state operation. Four-SCA-inverter arrangement shows up to 2.5% efficiency improvement by equally partitioning the load into four inverters with no load balancing issues. As the four supercapacitor modules are switched at millihertz order frequency, it eliminaties the need for any EMC filters and dynamic losses in the frontend SCA arrangement are negligible.Item type:Publication, Implementation of a supercapacitor assisted inverter system for reducing input loop losses: Preliminary results of a four-stage inverter2024, IEEESupercapacitor assisted loss management (SCALoM) concept has laid the theoretical foundation to develop high efficiency power converters for renewable energy systems using supercapacitors as lossless voltage droppers and energy buffers. SCALoM theory is applicable to inverter combinations in reducing overall losses, mainly occurring in the input loop, including losses in the DC bus capacitor. Supercapacitor assisted (SCA) multi-inverter technique reduces the voltage stress on the internal components of inverters enabling the use of more efficient lower voltage rated components. A summary of the theoretical foundations with reference to previous works on the topic is presented first. The four-SCA-inverter technique discussed in this paper extends the input voltage range of an inverter system by two times and reduces the input loop current by two times. The preliminary results obtained from the first experimental prototype of the 700W four-SCA-inverter system coupled with four identical 250F supercapacitor modules switched at low frequencies (less than 0.02 Hz), show up to 2.53% of efficiency gain at the inverter end. Additionally, proposed technique provides unquantified efficiency gains by reducing the ripple currents in the system, functioning as an energy buffer. Development of a high power capable SCA-inverter prototype is in progress.Item type:Publication, A supercapacitor assisted technique for reducing losses in the input loop of an inverter system for solar PV applications2024, IEEEThis paper presents a method of using supercapacitor modules in the input loop, to reduce the input losses of a typical inverter system used in solar applications. It is an extension of the supercapacitor-assisted loss management principle (SCALoM), where supercapacitors act as lossless droppers and energy buffers at the input end with a very low frequency switching scheme with reduced dynamic losses in switches compared to switched capacitor-inverter systems. The technique uses a set of micro-inverters, with the same total power capability as a single inverter, combined with a set of supercapacitor banks switching at a low frequency to reduce the voltage stress and rms current through the H-bridge input stages of the inverters, enhancing the end-to-end efficiency of the overall system. The proposed technique does not require a re-design of the commercially available inverters and adds DC-UPS capability to the system. Preliminary experimental results of the SCA(super capacitor assisted) two-inverter arrangement show stable transient and steady state operations, and the system is up to 2.2% efficient compared to a single central inverter arrangement. With the proposed SCA four-inverter configuration, inverter's overall power load can be further partitioned, and according to the analytical study further improvements in the overall efficiency can be achieved over the SCA two-inverter arrangement.