University of Waikato Research
Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288
Browse
46 results
Search Results
Item type:Publication, Industrial heat pump integration in non-continuous processes using thermal energy storages as utility - An NLP enhancement of the graphical approach2018The aim of this paper is to enhance the results of the graphical approach for Heat Pump (HP) integration in noncontinuous processes. A nonlinear programming (NLP) formulation is developed which optimizes temperature levels of condensation, evaporation, and storage temperature layers in order to further reduce total annual cost (TAC) and greenhouse gas (GHG) emissions. In addition, the NLP formulation requires low computation time given the practical approach. By its application on an AMMIX butter production of a large dairy factory, it is shown, that the temperature differences in the condenser and evaporator are reduced sharply which improves the COP of the HP from 2.2 to 3.4. As a result, the TAC can be reduced by an additional 16,721 NZD/y and the GHG emissions by an additional 29 tCO2/y in comparison to the graphical approach.Item type:Publication, Sustainable energy transition toward renewable energies in the New Zealand dairy industry: An environmental life cycle assessment2019, AIDIC Servizi S.r.l.The dairy processing industry is considered as energy-intensive processes between New Zealand industries that use fossil fuels as a primary energy source which results in greenhouse gas emissions as well as raising other environmental impacts. To mitigate the environmental impacts of fossil fuels that are used in dairy processing plants, it is essential to design a pathway moving from fossil-based energies towards renewable energy sources in a transition period. To do so, Life Cycle Assessment (LCA), as a standardised approach, has been implemented to quantify the environmental profile of different products by evaluating the environmental impacts of product systems. In this paper, three impact categories are considered adopting accessible inventory databases that match the regional and local data along with ReCiPe as the life cycle impact assessment method. These impact categories are 1) human health; 2) ecosystem; and 3) resources. Each category contains subcategories; seven different-statistically discernible energy mix scenarios (moving from coal through natural gas towards biomass) assisted by Monte Carlo simulation are defined to assess environmental impacts. Furthermore, Cumulative Exergy Demand (CExD) as an aggregated criterion has been exploited to indicate the sustainability of the whole system. Results show that for a cheese production process a biomass based scenario has the lowest environmental burden impact in 13 impact categories out of 14 studied impacts. Indeed, it has the lowest CExD with 1.05x10-5 MJ-Eq while surprisingly natural gas based scenario has the highest environmental burden with CExD of 3.85x10-1 MJ-Eq followed by coal with 4.73x10-4 MJ-Eq.Item type:Publication, Flexibility analysis of heat exchanger network retrofit designs using Monte Carlo Simulation2019The aim of this paper is to use Monte Carlo Simulation (MCS) to conduct an analysis of the flexibility and controllability of retrofitted Heat Exchanger Network (HEN) designs. Historical plant data is often uncertain and variable but is an important tool for understanding the real-time operation of a HEN. MCS uses these uncertainties to give an analysis of the retrofitted HENs, and it can be used in a more detailed analysis of the controllability and flexibility. Using Monte Carlo Simulation, inflexibility has been defined as the probability of a HEN to fail to meet temperature targets within defined tolerances. Inflexibility can be used as a tool to guide the retrofit analysis of a HEN. A retrofit HEN design should improve the flexibility of the network without compromising on the expected energy savings. The proposed method is demonstrated using a four-stream HEN problem. The inflexibility of the network was shown to be improved with bypass control and optimal allocation of retrofit area and the proposed method succeeds in augmenting the retrofit design method so that cost-effective, flexible retrofit HENs can be identified.Item type:Publication, Optimising energy recovery in hydrothermal liquefaction of radiata pine and Kraft mill black liquor2018The aim of this paper is to develop a heat exchanger network for hydrothermal liquefaction that is co-located with an existing Kraft pulp mill. Hydrothermal Liquefaction (HTL) is an energy-intensive process that operates at high temperature and pressure. Process Modelling and Pinch Analysis are used to develop a mass and heat integration system considering Total Site Integration with the Kraft pulp. The HTL process is simulated using Aspen Plus to extract and calculate the thermodynamic properties of the process. Stream data is then extracted and Pinch Analysis is applied to calculate the utility and heat recovery targets. Process data are varied to further maximise the heat recovery targets. Mass integration of compatible water-based flows is considered in this process to reduce the complexity of the Heat Exchanger Network, which is initially designed with the aid of SuperTarget™. The result showed that the procedure simplified the Heat Exchanger Network from 15 to 6 heat exchangers.Item type:Publication, Solving complex retrofit problems using constraints and bridge analysis2018The aim of this paper is to conduct retrofit analysis of large, complex industrial Heat Exchanger Networks using an automated Bridge Analysis. Large, complex networks have many different possible retrofit designs, or Retrofit Bridges, which requires both computational effort and user effort to evaluate. In this paper, constraints relating to the thermodynamic and economic performance of a retrofit design are proposed and applied to significantly reduce Retrofit Bridge options to a smaller, manageable number of design options. These constraints relate to capital costs, payback period, piping, and plant layout. The method is demonstrated with a Kraft pulp mill case study. The Kraft pulp mill currently has 54 heat exchangers and 73 hot and cold streams. Without constraints, the number of possible Retrofit Bridges is 1 x 10²⁰. After applying the constraints, this number is reduced to 15. The remaining Retrofit Bridges are considered to provide high thermodynamic and economic benefit and can be more easily assessed for the best projects. The use of constraints has allowed the complex case study to be solved quickly, and a single design can be selected for further development. The suggested design reduces the utility consumption by 9.2 MW and has an annual Total Retrofit Profit of NZD 2,140,000, requiring a single new exchanger.Item type:Publication, Accounting for stream variability in retrofit problems using Monte Carlo simulation2018The aim of this paper is to use Monte Carlo simulation to analyse the effect of stream data variation on the economic performance of retrofit designs. The input stream data is fitted to a distribution which can be sampled from to calculate the outputs of the Heat Exchanger Network model, stochastically. A simple four-stream problem is used to demonstrate the method, comparing two retrofit designs that each reduce the hot utility by 700 kW. Monte Carlo simulation analyses how the similar designs behave differently under the variable conditions and the results show that time-average analysis can not only overestimate the Total Retrofit Profit but can also favour a different design to that favoured by the Monte Carlo results. Of the two compared designs, the Design 2 was selected with an annual Total Retrofit Profit of NZD 215,553, requiring one new exchanger and additional area on an existing one. The Monte Carlo analysis also shed light on controllability and feasibility issues in the Heat Exchanger Network.Item type:Publication, Utility exchanger network design for non-isothermal utility considering process control2018This paper investigates a preliminary control strategy based on bypass control loop of Utility Exchangers Network (UEN) for non-isothermal utilities in a Total Site Heat Integration (TSHI) system. Few details on the design and control of non-isothermal utility systems, e.g. hot water loops, that includes Total Site heat recovery are presented in the literature. Heat Exchanger Networks (HEN) can be considered as a combined Heat Recovery Network (HRN) and UEN for each individual processes within the Total Site. Control strategy presented in the current paper are based on the control of utility side in a process – utility heat exchanger match to control process stream target temperature and analyse Total Site (TS) utility system in a Process Integration point of view. Bypass control has been used in the research. A Hot Water loop as representative of a large industrial plant utility system is studied as a case study. The process stream segment target temperature to be achieved and process stream segment supply temperature and flow rate may vary up to ±15 %. The HW utility temperature in the loop is controlled by using indirect heat transfer from higher and lower level utility and by using HW loop bypass. A 24 h period has been considered for the study. Results show that the HW utility loop has a 2.4 MW heat deficit in time-average condition. By controlling the HW utility loop using the proposed heuristics, utility heating requirement may vary between 0.7 to 3.5 MW, which is supplied by the Low Pressure steam main.Item type:Publication, Process integration in pulp and paper mills for energy and water reduction - A review2012, APPITAProcess integration (including pinch analysis) is a holistic or systems approach to process design and optimisation, which considers the interactions and interdependences between individual unit operations or process elements. Large reductions in both energy and water use in pulp and paper mills has been demonstrated using process integration techniques. A review of the current process integration techniques for energy and water reduction, with a focus on application to the pulp and paper industry is presented in this paper. The concurrent application of heat integration and water/mass integration analysis is discussed. Particular focus is given to published case studies. The integration of biorefineries into existing mills and the energy and water use implications is also receiving much attention and this development is also reviewed.Item type:Publication, Total site heat integration: Utility selection and optimisation using cost and exergy derivative analysis2017, ElsevierThis paper presents a new Total Site Heat Integration utility temperature selection and optimisation method that can optimise both non-isothermal (e.g. hot water) and isothermal (e.g. steam) utilities. None of the existing methods addresses both non-isothermal and isothermal utility selection and optimisation incorporated in a single procedure. The optimisation affects heat recovery, the number of heat exchangers in Total Site Heat Exchanger Network, heat transfer area, exergy destruction (ED), Utility Cost (UC), Annualised Capital Cost (CC), and Total Annualised Cost (TC). Three optimisation parameters, UC, ED, and TC have been incorporated into a derivative based optimisation procedure where derivatives are minimised sequentially and iteratively based on the specified approach. The new optimisation procedure has been carried out for three different approaches as the combinations of optimisation parameters based on the created derivative map. The merits of the new method have been illustrated using three case studies. These case studies represent a diverse range of processing types and temperatures. Results for the case studies suggest the best derivative optimisation approach is to first optimise UC in combination with ED and then optimise TC. For this approach, TC reductions between 0.6 to 4.6 % for different case studies and scenarios are achieved.Item type:Publication, A comparison of utility heat exchanger network synthesis for total site heat integration methods2017, AIDIC (Italian Association of Chemical Engineering)This paper compares Utility Heat Exchanger Network (UEN) design between two Total Site Heat Integration (TSHI) methods, the Conventional Total Site Targeting method (CTST) and the recently developed Unified Total Site Targeting (UTST) method. A large Kraft Pulp Mill plant has been chosen as a case study. Total Site targets have been calculated using a Excel ™ targeting spreadsheet and networks have been designed with the help of Supertaget ™ for both the CTST and UTST methods. To achieve heat recovery and utility targets, both series and parallel utility heat exchanger matches for non-isothermal utilities are allowed in the CTST method, while series matches are allowed in the UTST method if the heat exchangers in series are from the same process. Series matches based on CTST method may create a dependency on two or more separate processes, which operational and control issues may occur, higher piping costs may be imposed, and utility target temperatures may not be achieved in the consecutive processes if one or more processes were to be out of service. Relaxation of the network can resolve these issues for the CTST method; however, if the relaxation occurs on the side of the utility loop that constrains heat recovery, the net heat recovery targets may not be achieved within the Total Site. The UTST method with its modified targeting procedure may offer slightly lower heat recovery targets but with simpler UEN design compared to CTST method are more realistic and achievable. Finally, after UEN design, non-isothermal utility loops need to be balanced in terms of mass and energy for both methods.