University of Waikato Research
Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288
Browse
6 results
Search Results
Item type:Publication, Appropriate placement of vapour recompression in ultra-low energy industrial milk evaporation systems using Pinch Analysis2016, ElsevierThis study focuses on applying Pinch Analysis to an industrial milk evaporator case study to quantify the potential energy savings. Modern milk evaporators are typically integrated using both mechanical and thermal vapour recompression technologies as the primary means for attaining a high level of energy efficiency. A significant step change in energy efficiency for milk evaporators is achieved in this study by appropriate placement of vapour recompression in a new improved two-effect milk evaporation system design. The Grand Composite Curve helps identify areas for process modifications and placements of vapour recompression that result in energy reduction. In particular, the innovative placement of Mechanical Vapour Recompression in the system unlocks significant energy, energy cost, and emissions savings. The new design requires 78% less steam (6397 kW) at the expense of 16% (364 kWele) more electricity use. The estimated cost savings associated with the improved design is $942,601/y and the emissions reduction is 3416 t CO2-e/y. Further energy efficiency improvements and cost savings of $1,411,844/y are gained through improved Total Site Heat Integration through recovery of waste heat from the dryer exhaust air and boiler return condensate streams.Item type:Publication, Heat transfer enhancement for site level indirect heat recovery systems using nanofluids as the intermediate fluid2016, ElsevierIn this paper, implementation of nanofluids as a Heat Transfer Enhancement technique in Process Integration has been studied. A step by step flowchart is introduced and as a case study the effect of replacing water with various nanofluids as the heat transfer media in an industrial Heat Recovery Loop (HRL) has been modelled. Nanofluids are prepared by distributing a nanoparticle through a base fluid such as water, ethylene glycol or oils. Suspended nanoparticles slightly affect the thermal and physical properties of the base fluid. Primarily nanoparticles are added to improve the fluid’s heat transfer characteristics by increasing its Reynolds number and thermal conductivity. HRL system in a large dairy factory in New Zealand has been studied as case study. Results show that by applying various HRL design methods and a nanofluid as an intermediate fluid, an increase in heat recovery is possible without the need for extra heat exchanger area and infrastructure. 1.5 vol.% CuO/water nanofluid has been chosen as an intermediate fluid and by using a constant temperature storage control strategy, heat recovery from liquid–liquid heat exchangers increases between 5% and 9%. The air-side heat transfer coefficient limits the impact of using a nanofluid for the air–liquid exchangers. In other cases, the total available duty from the process stream, such as a condenser, significantly nullifies the heat transfer benefit of using a nano- fluid in a retrofit situation. Alternative to increasing heat recovery, results show that applying a nanofluid in the HRL design phase enables heat exchanger area to decrease significantly for liquid–liquid matches. Results show that the increase in pressure drop and friction factor effects in such a system is negligibleItem type:Publication, Pinch analysis of an industrial milk evaporator with vapour recompression technologies2015-08-24The present study focuses on applying Pinch Analysis to an industrial milk evaporator case study. Modern milk evaporators are typically integrated using both mechanical and thermal vapour recompression technologies as the primary means for attaining a high level of energy efficiency. A significant step change in energy efficiency for milk evaporators is achieved in this study by modifying the set-up of the concentration processing pathway in combination with an improved heat exchanger network design. To effectively perform the Pinch Analysis, a validated mass and energy balance model of the milk evaporator case study has been implemented in an Excel spreadsheet from which appropriate stream data may be extracted. In particular the Grand Composite Curve plays a critical role in identifying where vapour recompression units, which are a type of heat pump, may be applied to reduce thermal energy use by as much as 67%, which represents an annual utility cost saving between $640 – 820k /y.Item type:Publication, Integration of industrial solar and gaseous waste heat into heat recovery loops using constant and variable temperature storage2014, ElsevierSolar is a renewable energy that can be used to provide process heat to industrial sites but require thermal storage. HRLs (heat recovery loops) are an indirect method for transferring heat from one process to another using an intermediate fluid. With HRL's thermal storage is also necessary to effectively meet the stop/start time dependent nature of the multiple source and sink streams. Combining solar heating with HRL's is a cost effective way to share common storage and piping infrastructure. The conventional HRL design method based on a CTS (constant temperature storage) and a new HRL design method using VTS (variable temperature storage) are applied to demonstrate the potential benefits of inter-plant heat integration and installing solar heating. The dairy case study had available 12 source streams including four spray dryer exhausts and six sink streams. The addition of the dryer exhausts as heat sources was a critical factor in gaining a heat recovery of 10.8 MW for the variable temperature storage design, of which 5.1 MW was contributed from exhaust heat recovery. For the same minimum approach temperature the VTS approach achieved 37% more heat recovery compared to the CTS approach. Solar heating also proved to be a valuable source to be integrated into an HRL with a pinch around the cold storage tank with the maximum addition of 0.9 MW of heating on average for the CTS approach and 1.0 MW of heating on average for the VTS approach.Item type:Publication, Importance of understanding variable and transient energy demand in large multi-product industrial plants for process integration2011, AIDIC Servizi S.r.l.There have been some news releases claiming that Professor Henle in Germany has found the chemical identity of UMF, and that in future chemical analysis will be used instead of assays of antibacterial activity to indicate the level of UMF in manuka honey. Both of these claims are misleading. Because the level of active substance in manuka honey is an unreliable indication of the level of antibacterial activity and can be very misleading, it is hard to see any commercial advantage for it to be used to indicate antibacterial activity other than if someone wanted to fool the consumer into thinking that the higher numbers are giving them a level of antibacterial activity that is far higher than they are really getting.Item type:Publication, Integrating heat recovery from milk powder spray dryer exhausts in the dairy industry2011, ElsevierHeat recovery from milk powder spray dryer exhausts has proven challenging due to both economic and thermodynamic constraints. Integrating the dryer with the rest of the process (e.g. evaporation stages) can increase the viability of exhaust recovery. Several potential integration schemes for a milk powder plant have been investigated. Indirect heat transfer via a coupled loop between the spray dryer exhaust and various heat sinks were modeled and the practical heat recovery potential determined. Hot utility use was reduced by as much as 21% if suitable heat sinks are selected. Due to high particle loading and operating temperatures in the particle sticky regime, powder deposition in the exhaust heat exchanger is perhaps the greatest obstacle for implementing heat recovery schemes on spray dryers. Adequate cleaning systems are needed to ensure continuous dyer operation.