University of Waikato Research
Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288
Browse
14 results
Search Results
Item type:Publication, A power-saving modulation technique for time-of-flight range imaging sensors2011, Society of Photo-Optical Instrumentation EngineersTime-of-flight range imaging cameras measure distance and intensity simultaneously for every pixel in an image. With the continued advancement of the technology, a wide variety of new depth sensing applications are emerging; however a number of these potential applications have stringent electrical power constraints that are difficult to meet with the current state-of-the-art systems. Sensor gain modulation contributes a significant proportion of the total image sensor power consumption, and as higher spatial resolution range image sensors operating at higher modulation frequencies (to achieve better measurement precision) are developed, this proportion is likely to increase. The authors have developed a new sensor modulation technique using resonant circuit concepts that is more power efficient than the standard mode of operation. With a proof of principle system, a 93–96% reduction in modulation drive power was demonstrated across a range of modulation frequencies from 1–11 MHz. Finally, an evaluation of the range imaging performance revealed an improvement in measurement linearity in the resonant configuration due primarily to the more sinusoidal shape of the resonant electrical waveforms, while the average precision values were comparable between the standard and resonant operating modes.Item type:Publication, Illumination waveform optimization for time-of-flight range imaging cameras2011, Society of Photo-Optical Instrumentation EngineersTime-of-flight range imaging sensors acquire an image of a scene, where in addition to standard intensity information, the range (or distance) is also measured concurrently by each pixel. Range is measured using a correlation technique, where an amplitude modulated light source illuminates the scene and the reflected light is sampled by a gain modulated image sensor. Typically the illumination source and image sensor are amplitude modulated with square waves, leading to a range measurement linearity error caused by aliased harmonic components within the correlation waveform. A simple method to improve measurement linearity by reducing the duty cycle of the illumination waveform to suppress problematic aliased harmonic components is demonstrated. If the total optical power is kept constant, the measured correlation waveform amplitude also increases at these reduced illumination duty cycles. Measurement performance is evaluated over a range of illumination duty cycles, both for a standard range imaging camera configuration, and also using a more complicated phase encoding method that is designed to cancel aliased harmonics during the sampling process. The standard configuration benefits from improved measurement linearity for illumination duty cycles around 30%, while the measured amplitude, hence range precision, is increased for both methods as the duty cycle is reduced below 50% (while maintaining constant optical power).Item type:Publication, Proof of concept of diffuse optical tomography using time-of-flight range imaging cameras2010, School of Engineering, The University of WaikatoDiffuse optical tomography is an optical technique to create 3-dimensional images of the inside of highly scattering material. Research groups around the world have been developing imaging systems using various source-detector arrangements to determine optical properties of biological tissue with a focus on medical applications. In this paper we investigate whether a range imaging camera can be used as a detector array. We used time-of-flight range imaging cameras instead of the conventional source-detector array used by others. The results provided in this paper show reconstructed images of absorption and reduced scattering of an object submerged in a tissue simulating phantom. Using the ranging camera XZ422 Demonstrator and the NIRFAST software package, we reconstructed 2D images of a 6 mm metal rod submerged in the centre of a 5 cm deep tank filled with 1% IntralipidTM. We have shown for the first time that range imaging cameras can replace the traditional detectors in diffuse optical tomography.Item type:Publication, Advantages of 3D time-of-flight range imaging cameras in machine vision applications2009, Electronics ResearchMachine vision using image processing of traditional intensity images is in wide spread use. In many situations environmental conditions or object colours or shades cannot be controlled, leading to difficulties in correctly processing the images and requiring complicated processing algorithms. Many of these complications can be avoided by using range image data, instead of intensity data. This is because range image data represents the physical properties of object location and shape, practically independently of object colour or shading. The advantages of range image processing are presented, along with three example applications that show how robust machine vision results can be obtained with relatively simple range image processing in real-time applications.Item type:Publication, Maximizing precision over extended unambiguous range for TOF range imaging systems2010, IEEEThe maximum unambiguous range for time-of-flight range imaging systems is inversely proportional to the chosen modulation frequency. However, increasing the unambiguous range by decreasing the modulation frequency will generally also degrade the range measurement precision. We describe a technique that significantly extends the range of a time-of-flight imaging system without compromising range precision. This is achieved by employing two modulation frequencies simultaneously. The chosen frequencies can be a combination of high and low frequency, or two similarly high frequencies. In this paper we present experimental results comparing single frequency; dual high and low frequency; and dual high frequency operation and demonstrate that range precision need not be appreciably compromised to achieve an extended unambiguous range.Item type:Publication, Development of a real-time full-field range imaging system2009, Springer-Verlag Berlin HeidelbergThis article describes the development of a full-field range imaging system employing a high frequency amplitude modulated light source and image sensor. Depth images are produced at video frame rates in which each pixel in the image represents distance from the sensor to objects in the scene. The various hardware subsystems are described as are the details about the firmware and software implementation for processing the images in real-time. The system is flexible in that precision can be traded off for decreased acquisition time. Results are reported to illustrate this versatility for both high-speed (reduced precision) and high-precision operating modes.Item type:Publication, Development and characterisation of an easily configurable range imaging system2009, IEEERange imaging is becoming a popular tool for many applications, with several commercial variants now available. These systems find numerous real world applications such as interactive gaming and the automotive industry. This paper describes the development of a range imaging system employing the PMD-19 k sensor from PMD technologies. One specific advantage of our system is that it is extremely customisable in terms of modulation patterns to act as a platform for further research into time-of-flight range imaging. Experimental results are presented giving an indication of the precision and accuracy of the system, and how modifying certain operating parameters can improve system performance.Item type:Publication, Calibration and control of a robot arm using a range imaging camera2010, IS&T- the Society for Imaging Science and Technology SPIETime of flight range imaging is an emerging technology that has numerous applications in machine vision. In this paper we cover the use of a commercial time of flight range imaging camera for calibrating a robotic arm. We do this by identifying retro-reflective targets attached to the arm, and centroiding on calibrated spatial data, which allows precise measurement of three dimensional target locations. The robotic arm is an inexpensive model that does not have positional feedback, so a series of movements are performed to calibrate the servos signals to the physical position of the arm. The calibration showed a good linear response between the control signal and servo angles. The calibration procedure also provided a transformation between the camera and arm coordinate systems. Inverse kinematic control was then used to position the arm. The range camera could also be used to identify objects in the scene. With the object location now known in the arm's coordinate system (transformed from the camera's coordinate system) the arm was able to move allowing it to grasp the object.Item type:Publication, Multiple range imaging camera operation with minimal performance impact2010, SPIETime-of-flight range imaging cameras operate by illuminating a scene with amplitude modulated light and measuring the phase shift of the modulation envelope between the emitted and reflected light. Object distance can then be calculated from this phase measurement. This approach does not work in multiple camera environments as the measured phase is corrupted by the illumination from other cameras. To minimize inaccuracies in multiple camera environments, replacing the traditional cyclic modulation with pseudo-noise amplitude modulation has been previously demonstrated. However, this technique effectively reduced the modulation frequency, therefore decreasing the distance measurement precision (which has a proportional relationship with the modulation frequency). A new modulation scheme using maximum length pseudo-random sequences binary phase encoded onto the existing cyclic amplitude modulation, is presented. The effective modulation frequency therefore remains unchanged, providing range measurements with high precision. The effectiveness of the new modulation scheme was verified using a custom time-of-flight camera based on the PMD19-K2 range imaging sensor. The new pseudo-noise modulation has no significant performance decrease in a single camera environment. In a two camera environment, the precision is only reduced by the increased photon shot noise from the second illumination source.Item type:Publication, Resolving depth measurement ambiguity with commercially available range imaging cameras2010, SPIETime-of-flight range imaging is typically performed with the amplitude modulated continuous wave method. This involves illuminating a scene with amplitude modulated light. Reflected light from the scene is received by the sensor with the range to the scene encoded as a phase delay of the modulation envelope. Due to the cyclic nature of phase, an ambiguity in the measured range occurs every half wavelength in distance, thereby limiting the maximum useable range of the camera. This paper proposes a procedure to resolve depth ambiguity using software post processing. First, the range data is processed to segment the scene into separate objects. The average intensity of each object can then be used to determine which pixels are beyond the non-ambiguous range. The results demonstrate that depth ambiguity can be resolved for various scenes using only the available depth and intensity information. This proposed method reduces the sensitivity to objects with very high and very low reflectance, normally a key problem with basic threshold approaches. This approach is very flexible as it can be used with any range imaging camera. Furthermore, capture time is not extended, keeping the artifacts caused by moving objects at a minimum. This makes it suitable for applications such as robot vision where the camera may be moving during captures. The key limitation of the method is its inability to distinguish between two overlapping objects that are separated by a distance of exactly one non-ambiguous range. Overall the reliability of this method is higher than the basic threshold approach, but not as high as the multiple frequency method of resolving ambiguity.