University of Waikato Research
Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288
Browse
29 results
Search Results
Item type:Publication, A power-saving modulation technique for time-of-flight range imaging sensors2011, Society of Photo-Optical Instrumentation EngineersTime-of-flight range imaging cameras measure distance and intensity simultaneously for every pixel in an image. With the continued advancement of the technology, a wide variety of new depth sensing applications are emerging; however a number of these potential applications have stringent electrical power constraints that are difficult to meet with the current state-of-the-art systems. Sensor gain modulation contributes a significant proportion of the total image sensor power consumption, and as higher spatial resolution range image sensors operating at higher modulation frequencies (to achieve better measurement precision) are developed, this proportion is likely to increase. The authors have developed a new sensor modulation technique using resonant circuit concepts that is more power efficient than the standard mode of operation. With a proof of principle system, a 93–96% reduction in modulation drive power was demonstrated across a range of modulation frequencies from 1–11 MHz. Finally, an evaluation of the range imaging performance revealed an improvement in measurement linearity in the resonant configuration due primarily to the more sinusoidal shape of the resonant electrical waveforms, while the average precision values were comparable between the standard and resonant operating modes.Item type:Publication, Illumination waveform optimization for time-of-flight range imaging cameras2011, Society of Photo-Optical Instrumentation EngineersTime-of-flight range imaging sensors acquire an image of a scene, where in addition to standard intensity information, the range (or distance) is also measured concurrently by each pixel. Range is measured using a correlation technique, where an amplitude modulated light source illuminates the scene and the reflected light is sampled by a gain modulated image sensor. Typically the illumination source and image sensor are amplitude modulated with square waves, leading to a range measurement linearity error caused by aliased harmonic components within the correlation waveform. A simple method to improve measurement linearity by reducing the duty cycle of the illumination waveform to suppress problematic aliased harmonic components is demonstrated. If the total optical power is kept constant, the measured correlation waveform amplitude also increases at these reduced illumination duty cycles. Measurement performance is evaluated over a range of illumination duty cycles, both for a standard range imaging camera configuration, and also using a more complicated phase encoding method that is designed to cancel aliased harmonics during the sampling process. The standard configuration benefits from improved measurement linearity for illumination duty cycles around 30%, while the measured amplitude, hence range precision, is increased for both methods as the duty cycle is reduced below 50% (while maintaining constant optical power).Item type:Publication, Efficient FPGA implementation of homodyne-based time-of-flight range imaging2010, SpringerTime-of-flight range imaging systems illuminate a scene with an amplitude-modulated light source, the light is reflected from objects in the scene, and measurement of the phase of the modulation envelope is performed to determine the object’s distance. As the image sensor is capable of performing this task for every pixel simultaneously, acquisition of the entire scene can be performed at rapid (video) update rates, making the technology ideal for real-time applications. In this paper we present an efficient real-time FPGA algorithm for determining phase, and hence distance, from the raw image sensor output. The algorithm has been implemented on a range imaging system based on the PMD19k-2 image sensor, with range processing performed in real time by a Stratix III FPGA. The scarcest resource in this implementation is RAM, and an analysis is presented to maximise the efficiency of this resource whilst maintaining acceptable processing accuracy. The algorithm can be extended for processing multiple simultaneous modulation frequencies. An efficient method for combining these results to determine unambiguous range, based on the Chinese remainder theorem, is also presented.Item type:Publication, Proof of concept of diffuse optical tomography using time-of-flight range imaging cameras2010, School of Engineering, The University of WaikatoDiffuse optical tomography is an optical technique to create 3-dimensional images of the inside of highly scattering material. Research groups around the world have been developing imaging systems using various source-detector arrangements to determine optical properties of biological tissue with a focus on medical applications. In this paper we investigate whether a range imaging camera can be used as a detector array. We used time-of-flight range imaging cameras instead of the conventional source-detector array used by others. The results provided in this paper show reconstructed images of absorption and reduced scattering of an object submerged in a tissue simulating phantom. Using the ranging camera XZ422 Demonstrator and the NIRFAST software package, we reconstructed 2D images of a 6 mm metal rod submerged in the centre of a 5 cm deep tank filled with 1% IntralipidTM. We have shown for the first time that range imaging cameras can replace the traditional detectors in diffuse optical tomography.Item type:Publication, Separating true range measurements from multi-path and scattering interference in commercial range cameras2011, SPIE--The International Society for Optical EngineeringTime-of-flight range cameras acquire a three-dimensional image of a scene simultaneously for all pixels from a single viewing location. Attempts to use range cameras for metrology applications have been hampered by the multi-path problem, which causes range distortions when stray light interferes with the range measurement in a given pixel. Correcting multi-path distortions by post-processing the three-dimensional measurement data has been investigated, but enjoys limited success because the interference is highly scene dependent. An alternative approach based on separating the strongest and weaker sources of light returned to each pixel, prior to range decoding, is more successful, but has only been demonstrated on custom built range cameras, and has not been suitable for general metrology applications. In this paper we demonstrate an algorithm applied to both the Mesa Imaging SR-4000 and Canesta Inc. XZ-422 Demonstrator unmodified off-the-shelf range cameras. Additional raw images are acquired and processed using an optimization approach, rather than relying on the processing provided by the manufacturer, to determine the individual component returns in each pixel. Substantial improvements in accuracy are observed, especially in the darker regions of the scene.Item type:Publication, Design and construction of a configurable full-field range imaging system for mobile robotic applications2011, Springer VerlagMobile robotic devices rely critically on extrospection sensors to determine the range to objects in the robot’s operating environment. This provides the robot with the ability both to navigate safely around obstacles and to map its environment and hence facilitate path planning and navigation. There is a requirement for a full-field range imaging system that can determine the range to any obstacle in a camera lens’ field of view accurately and in real-time. This paper details the development of a portable full-field ranging system whose bench-top version has demonstrated sub-millimetre precision. However, this precision required non-real-time acquisition rates and expensive hardware. By iterative replacement of components, a portable, modular and inexpensive version of this full-field ranger has been constructed, capable of real-time operation with some (user-defined) trade-off with precision.Item type:Publication, Improved measurement linearity and precision for AMCW time-of-flight range imaging cameras2010, Optical Society of AmericaTime-of-flight range imaging systems utilizing the amplitude modulated continuous wave (AMCW) technique often suffer from measurement nonlinearity due to the presence of aliased harmonics within the amplitude modulation signals. Typically a calibration is performed to correct these errors. We demonstrate an alternative phase encoding approach that attenuates the harmonics during the sampling process, thereby improving measurement linearity in the raw measurements. This mitigates the need to measure the system’s response or calibrate for environmental changes. In conjunction with improved linearity, we demonstrate that measurement precision can also be increased by reducing the duty cycle of the amplitude modulated illumination source (while maintaining overall illumination power).Item type:Publication, Advantages of 3D time-of-flight range imaging cameras in machine vision applications2009, Electronics ResearchMachine vision using image processing of traditional intensity images is in wide spread use. In many situations environmental conditions or object colours or shades cannot be controlled, leading to difficulties in correctly processing the images and requiring complicated processing algorithms. Many of these complications can be avoided by using range image data, instead of intensity data. This is because range image data represents the physical properties of object location and shape, practically independently of object colour or shading. The advantages of range image processing are presented, along with three example applications that show how robust machine vision results can be obtained with relatively simple range image processing in real-time applications.Item type:Publication, Multiple frequency range imaging to remove measurement ambiguity2009Range imaging systems use a specialised sensor to capture an image where object distance (range) is measured for every pixel using time-of-flight. The scene is illuminated with an amplitude modulated light source, and the phase of the modulation envelope of the reflected light is measured to determine flight time, hence object distance for each pixel. As the modulation waveform is cyclic, an ambiguity problem exists if the phase shift exceeds 2π radians. To overcome this problem we demonstrate a method that superposes two different modulation frequencies within a single capture. This technique reduces the associated overhead compared with performing two sequential measurements, allowing the system to retain high range measurement precision at rapid acquisition rates. A method is also provided to avoid interference from aliased harmonics during sampling, which otherwise contaminate the resulting range measurement. Experimental results show the potential of the multiple frequency approach; producing high measurement precision while avoiding ambiguity. The results also demonstrate the limitation of this technique, where large errors can be introduced through a combination of a low signal to noise ratio and suboptimal selection of system parameters.Item type:Publication, Maximizing precision over extended unambiguous range for TOF range imaging systems2010, IEEEThe maximum unambiguous range for time-of-flight range imaging systems is inversely proportional to the chosen modulation frequency. However, increasing the unambiguous range by decreasing the modulation frequency will generally also degrade the range measurement precision. We describe a technique that significantly extends the range of a time-of-flight imaging system without compromising range precision. This is achieved by employing two modulation frequencies simultaneously. The chosen frequencies can be a combination of high and low frequency, or two similarly high frequencies. In this paper we present experimental results comparing single frequency; dual high and low frequency; and dual high frequency operation and demonstrate that range precision need not be appreciably compromised to achieve an extended unambiguous range.