University of Waikato Research
Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288
Browse
5 results
Search Results
Item type:Publication, Heat pump bridge analysis using the modified energy transfer diagram2021, MDPIHeat pumps are the key technology to decarbonise thermal processes by upgrading industrial surplus heat using renewable electricity. Existing insight-based integration methods refer to the idealised Grand Composite Curve requiring the full exploitation of heat recovery potential but leave the question of how to deal with technical or economic limitations unanswered. In this work, a novel Heat Pump Bridge Analysis (HPBA) is introduced for practically targeting technical and economic heat pump potential by applying Coefficient of Performance curves into the Modified Energy Transfer Diagram (METD). Removing cross-Pinch violations and operating heat exchangers at minimum approach temperatures by combined application of Bridge Analysis increases the heat recovery rate and reduce the temperature lift to be pumped at the same time. The insight-based METD allows the individual matching of heat surpluses and deficits of individual streams with the capabilities and performance of different market-available heat pump concepts. For an illustrative example, the presented modifications based on HPBA increase the economically viable share of the technical heat pump potential from 61% to 79%.Item type:Publication, Hardware in the loop evaluation of a hybrid heating system for increased energy efficiency and management2016This study presents the tests of a hybrid heating prototype, designed for retrofitting thermal treatment plants like pasteurization, to use hot water and steam in controlled ratios. In the food industry, steam with a temperature above 140°C usually supplies the thermal production processes. The majority of processes require temperatures below 100°C and could be supplied more eficiently by cogeneration, heat recovery or heat pumps. These low temperature heat sources can only be combined with the rigid steam system if the demand structure is changed to a hybrid use of hot water below 100°C and steam. The hybrid heating system (H2S) increases the energy efficiency by integrating the highest possible amount of low temperature heat and responds to sudden changes in the supply structure, like demand response strategies on intermittent renewable energies and the changing availability of hot water and steam. The technical implementation is realised by a hydraulic interconnection of heat exchangers and valves. A smart algorithm controls the integration of hot water and steam into the thermal process. For reasons of food safety and product quality defined process temperatures have to be met. Prerequisite for functional verification on a laboratory scale is a simulation of the process heat demand and potential of hot water during the entire production cycle. The load profiles and relevant process parameters are passed in real time to a hardware-in-the loop (HIL) test-bed and returned to the simulation respectively. Two scenarios, hot water integration from heat pump and demand response management with a gas engine CHP and an electrical steam generator, were evaluated and the functionality of the H2S was proved. Up to 78 % of the final energy demand can be reduced by the H2S based implementation of a heat pump. The control response of the system, even with fluctuating hot water potential and temperature, met the requirements of the dairy industry.Item type:Publication, Design of robust total site heat recovery loops via Monte Carlo simulation2019, MDPIFor increased total site heat integration, the optimal sizing and robust operation of a heat recovery loop (HRL) are prerequisites for economic efficiency. However, sizing based on one representative time series, not considering the variability of process streams due to their discontinuous operation, often leads to oversizing. The sensitive evaluation of the performance of an HRL by Monte Carlo (MC) simulation requires sufficient historical data and performance models. Stochastic time series are generated by distribution functions of measured data. With these inputs, one can then model and reliably assess the benefits of installing a new HRL. A key element of the HRL is a stratified heat storage tank. Validation tests of a stratified tank (ST) showed sufficient accuracy with acceptable simulation time for the variable layer height (VLH) multi-node (MN) modelling approach. The results of the MC simulation of the HRL system show only minor yield losses in terms of heat recovery rate (HRR) for smaller tanks. In this way, costs due to oversizing equipment can be reduced by better understanding the energy-capital trade-off.Item type:Publication, Evaluation of a stratified tank based heat recovery loop via dynamic simulation2018Prerequisite for hot water recovery in the dairy and beverage industry is the use of heat storage, such as stratified tanks. Total Site Heat Integration enables the targeting of heat recovery potential, the concrete identification of suitable sinks and source profiles and the dimensioning of intermediate circuits and storages. For a cost and energy efficient storage, the aim to maintain stratification by suitable thermocline control management. Dynamic simulation enables a reliable estimation of energy savings and correct storage/control design considering the changing operation times, source and sink loads as well as thermal inertias. This poses two challenges: model accuracy and acceptable simulation time. A stratified tank model with Variable Layer Height (VLH) is evolved reducing numeric diffusion effects. A sensitive analysis shows the increased accuracy with acceptable simulation time. As part of a case study, thermocline growth due to numeric diffusion is reduced up to approximately 35 % by a VLH model. The model is simulated for a case study in the dairy industry. It is shown that up to 94 % of the total heat recovery target can be achieved by the modelled heat recovery loop based on a stratified tank and the applied system control.Item type:Publication, Hybrid-heating-systems for optimized integration of low-temperature-heat and renewable energy2016, AIDICThe food and beverage industries are significant industrial producers of green-house gas (GHG) emissions. Reductions can be achieved by increased energy efficiency and the use of renewable energy to replace fossil fuel use. The main efficiency method within this industries is the use of low temperature heat (LTH), i.e. below 100 °C. Sources for LTH include heat recovery from process flows, heat rejection from utility operations (i.e. chillers, combined heat and power (CHP), condensing economisers), and renewable energy (i.e. solar thermal). A hybrid heating system (H2S) has been developed that can retrofit steam heater designs for the integration of LTH. Two different systems have been found, for adapting direct and indirect steam heaters, either installing an extra hot water heater or using the indirect hot water loop for the integration. In both systems the existing steam heater remains a part of the system for individual back-up. The set-up and the control algorithm of the H₂S allow installing a 37 % smaller hot water grid than a common design with one central back-up heater. Investigations using a comprehensive model of a whey separation and drying plant showed that implementing a piston engine CHP unit combined with the H₂S reduce the energy costs by 42 % and the GHG emissions by 33 %.