  • Item type:Publication,
    Cortical entropy changes with general anaesthesia: theory and experiment
    2004, Institute of Physics Publishing
    Commonly used general anaesthetics cause a decrease in the spectral entropy of the electroencephalogram as the patient transits from the conscious to the unconscious state. Although the spectral entropy is a configurational entropy, it is plausible that the spectral entropy may be acting as a reliable indicator of real changes in cortical neuronal interactions. Using a mean field theory, the activity of the cerebral cortex may be modelled as fluctuations in mean soma potential around equilibrium states. In the adiabatic limit, the stochastic differential equations take the form of an Ornstein–Uhlenbeck process. It can be shown that spectral entropy is a logarithmic measure of the rate of synaptic interaction. This model predicts that the spectral entropy should decrease abruptly from values ~1.0 to values of ~0.7 as the patient becomes unconscious during induction of general anaesthesia, and then not decrease significantly on further deepening of anaesthesia. These predictions were compared with experimental results in which electrocorticograms and brain concentrations of propofol were recorded in seven sheep during induction of anaesthesia with intravenous propofol. The observed changes in spectral entropy agreed with the theoretical predictions. We conclude that spectral entropy may be a sensitive monitor of the consciousness–unconsciousness transition, rather than a progressive indicator of anaesthetic drug effect.
  • Item type:Publication,
    Does bispectral analysis of the electroencephalogram add anything but complexity?
    2004, Oxford University Press
    Background: Analysis of the bispectrum of EEG waveforms is a component of the proprietary BIS index—a commonly used commercial monitor of depth of anaesthesia. Does the use of the bispectrum give more information about depth of anaesthesia than the power spectrum? Methods: We collected and analysed EEG waveforms during induction of general anaesthesia in 39 patients, comparing the changes in bispectral parameter (SynchFastSlow), with an analogous power spectrum-based parameter (PowerFastSlow). Both compare the logarithmic ratio of high frequency components (40–47 Hz) with the total (1–47 Hz). Because the changes in bispectrum are affected by signal amplitude, we also calculated a third parameter (SFSbicoh) from the bicoherence, which is an amplitude-independent statistic. Results: The SynchFastSlow and PowerFastSlow were correlated (r=0.84) and neither was superior in predicting the awake or anaesthetized state (area under receiver operating characteristic curves = 0.85 vs 0.93). There was no change in the SFSbicoh over the induction period, and it did not correlate with SynchFastSlow (r=0.07). Conclusions: We could not show that bispectral analysis gave more information than power spectral-based analysis. Most of the changes in the bispectral values result from decreases in the relative high frequency content of the EEG caused by anaesthesia.
  • Item type:Publication,
    Comparison of changes in electroencephalographic measures during induction of general anaesthesia: influence of the gamma frequency band and electromyogram signal
    2001, Oxford University Press
    Recent research has shown that high-frequency, gamma-band electroencephalographic (EEG) oscillations (40–60 Hz) may be an important marker of the conscious state. We compared the ability of the bispectral index (BIS) to distinguish the awake and anaesthetized states during the induction of general anaesthesia with: (i) components of the BIS (BetaRatio, SynchFastSlow); (ii) a new EEG variable—the median frequency of the first time derivative of the EEG signal (SE50d); and (iii) the SE50d derived from an EEG signal that has had the frequencies above 30 Hz removed (SE50d30Hz). Two groups of subjects were studied: (i) nine volunteers undergoing a short propofol infusion until loss of response to verbal command, and (ii) 84 patients undergoing routine anaesthesia for a variety of surgical procedures. In the volunteer group, the changes in the BetaRatio and SE50d were comparable with changes in the BIS. The changes in the SE50d30Hz were less consistent. In the patient group, the BIS components were equivalent to the BIS in separating the awake from the surgically anaesthetized states (area under receiver operating curve: BIS 0.95, SE50d 0.95, BetaRatio 0.96). Using the submental electromyogram (EMG) signal to estimate the frontalis EMG (30–47 Hz) signal, the changes in EMG signal were, on average, about one-tenth the magnitude of the EEG. We conclude that: (i) there exist simpler derived EEG variables that are similar in accuracy to the BIS; (ii) it is important to avoid filtering out the EEG frequencies above 30 Hz; and (iii) in most patients the confounding effects of the frontalis EMG on the EEG are minimal.