University of Waikato Research
Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288
Browse
5 results
Search Results
Item type:Publication, Ground Plane Segmentation of Time-of-Flight Images for Asparagus Harvesting2018, IEEEA key task in processing time-of-flight images for the detection of asparagus spears is the identification and segmentation of the ground plane. In this paper, we aim to compare the performance of RANSAC with a modified version of an existing deterministic method, namely Hyun’s method. Each method is tested on scenes with varying amounts of field clutter. Additionally, a variety of camera angles are investigated. We find that both RANSAC and the proposed method produce ground plane predictions with a root mean square error of less than 0.05m and execute at a rate of approximately 0.056s per frame. However, RANSAC was shown to be much less reliable in high clutter scenes. The camera mounting angle is found to significantly affect the density and noise of points in time-of-flight images. These factors translate to significantly worse performance for both methods at low camera angles.Item type:Publication, Signal processing approaches for Jitter extraction in time-of-flight range imaging cameras2018, IEEEThe precision and accuracy of time-of-flight full-field range cameras are important for many applications, however there are a number of noise sources that degrade both precision and accuracy. Many of the noise sources such as nonlinearity, multipath inferences and harmonic cancellation are well investigated. Barely investigated is jitter on the camera light and shutter signals. Here we measure periodic and random jitter on the light signal of a camera. We use signal processing techniques to construct a reference signal, hence find the jitter. The performance of the proposed method is examined using the MESA Imaging SwissRanger 4000. We found periodic jitter of two frequencies at 0.12 and 5.04 MHz and the random jitter of 164 ± 4 ps, on the light signal of the camera.Item type:Publication, A strategy for the correction of effects of jitter in AMCW lidar images2013, IEEEFull-field range imaging cameras, which are an example of amplitude modulated continuous wave (AMCW) lidar, are subject to multiple error sources. In this paper we consider the possibility that a global jitter and/or drift occurs between the modulation signals to the active illumination source and the camera sensor. A model for jitter is presented and is used to characterise the jitter in a real camera system. Correction of the effects of jitter in real acquired range images is demonstrated by a reduction of the standard deviation of random noise by up to a factor of five, with the best reductions occurring in pixels that receive a strong signal.Item type:Publication, Extracting the MESA SR4000 Calibrations2015, SPIETime-of-flight range imaging cameras are capable of acquiring depth images of a scene. Some algorithms require these cameras to be run in `raw mode', where any calibrations from the off-the-shelf manufacturers are lost. The calibration of the MESA SR4000 is herein investigated, with an attempt to reconstruct the full calibration. Possession of the factory calibration enables calibrated data to be acquired and manipulated even in “raw mode.” This work is motivated by the problem of motion correction, in which the calibration must be separated into component parts to be applied at different stages in the algorithm. There are also other applications, in which multiple frequencies are required, such as multipath interference correction. The other frequencies can be calibrated in a similar way, using the factory calibration as a base. A novel technique for capturing the calibration data is described; a retro-reflector is used on a moving platform, which acts as a point source at a distance, resulting in planar waves on the sensor. A number of calibrations are retrieved from the camera, and are then modelled and compared to the factory calibration. When comparing the factory calibration to both the “raw mode” data, and the calibration described herein, a root mean squared error improvement of 51:3mm was seen, with a standard deviation improvement of 34:9mm. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.Item type:Publication, Design of a Pseudo-Holographic Distributed Time-of-Flight Sonar Range-Imaging System2016, IEEEThe design of an audible sonar distributed sensor time-of-flight range imaging system is investigated, sonar being chosen as a substitute for optical range imaging due to cost and simplicity of implementation. The distributed range imaging system proposed is based on the holographic principle where the sensors detect the self interference of the reflected sound from the scene, and the Fourier analysis computes the reflected object profile. An approximate linearised model used in related holographic imaging techniques is found to be inappropriate for the design, and qualitative assessment of simulations show that removing the linearisation dramatically improves image reconstruction. Quantitatively the nonlinear reconstruction improves the RMSE by a factor of 1.3-2.1 times. The full nonlinear reconstruction is slow, and mathematical development lead to 15 fold reduction in computation time.