<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

University of Waikato Research

Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288

Browse

Search Results

Now showing 1 - 8 of 8
  • Item type:Publication,
    The 'DEEP' Landing Error Scoring System
    2020, MDPI
    The Landing Error Scoring System (LESS) is an injury-risk screening tool used in sports; but scoring is time consuming, clinician-dependent, and generally inaccessible outside of elite sports. Our aim is to evidence that LESS scores can be automated using deep-learning-based computer vision combined with machine learning and compare the accuracy of LESS predictions using different video cropping and machine learning methods. Two-dimensional videos from 320 double-leg drop-jump landings with known LESS scores were analysed in OpenPose. Videos were cropped to key frames manually (clinician) and automatically (computer vision), and 42 kinematic features were extracted. A series of 10 × 10-fold cross-validation experiments were applied on full and balanced datasets to predict LESS scores. Random forest for regression outperformed linear and dummy regression models, yielding the lowest mean absolute error (1.23) and highest correlation (r = 0.63) between manual and automated scores. Sensitivity (0.82) and specificity (0.77) were reasonable for risk categorization (high-risk LESS ≥ 5 errors). Experiments using either a balanced (versus unbalanced) dataset or manual (versus automated) cropping method did not improve predictions. Further research on the automation would enhance the strength of the agreement between clinical and automated scores beyond its current levels, enabling quasi real-time scoring.
  • Item type:Publication,
    Time-of-flight range image measurement in the presence of transverse motion using the Kalman filter
    2018, IEEE
    Time-of-flight range imaging cameras measure distance to objects in their field of view, but are prone to error when objects move. At least three raw frames are required to obtain one range image, and the standard method is to read out raw frames into separate sets and process to find one range image per set. Motion during the acquisition of a set causes error in the corresponding range image. In this paper, the problem of motion is addressed by regarding the raw data from each pixel as a noisy time series, and using the Kalman filter to efficiently perform time-series analysis. The proposed method adapts to the effects of transverse motion, measuring a sharp range image at each raw frame. The error in the proposed method is less than the traditional approach in 80% of tests, with no detected increase in the STD due to noise. In the qualitative experimental results, the visible blur is reduced.
  • Item type:Publication,
    Ground Plane Segmentation of Time-of-Flight Images for Asparagus Harvesting
    2018, IEEE
    A key task in processing time-of-flight images for the detection of asparagus spears is the identification and segmentation of the ground plane. In this paper, we aim to compare the performance of RANSAC with a modified version of an existing deterministic method, namely Hyun’s method. Each method is tested on scenes with varying amounts of field clutter. Additionally, a variety of camera angles are investigated. We find that both RANSAC and the proposed method produce ground plane predictions with a root mean square error of less than 0.05m and execute at a rate of approximately 0.056s per frame. However, RANSAC was shown to be much less reliable in high clutter scenes. The camera mounting angle is found to significantly affect the density and noise of points in time-of-flight images. These factors translate to significantly worse performance for both methods at low camera angles.
  • Item type:Publication,
    Signal processing approaches for Jitter extraction in time-of-flight range imaging cameras
    2018, IEEE
    The precision and accuracy of time-of-flight full-field range cameras are important for many applications, however there are a number of noise sources that degrade both precision and accuracy. Many of the noise sources such as nonlinearity, multipath inferences and harmonic cancellation are well investigated. Barely investigated is jitter on the camera light and shutter signals. Here we measure periodic and random jitter on the light signal of a camera. We use signal processing techniques to construct a reference signal, hence find the jitter. The performance of the proposed method is examined using the MESA Imaging SwissRanger 4000. We found periodic jitter of two frequencies at 0.12 and 5.04 MHz and the random jitter of 164 ± 4 ps, on the light signal of the camera.
  • Item type:Publication,
    A strategy for the correction of effects of jitter in AMCW lidar images
    2013, IEEE
    Full-field range imaging cameras, which are an example of amplitude modulated continuous wave (AMCW) lidar, are subject to multiple error sources. In this paper we consider the possibility that a global jitter and/or drift occurs between the modulation signals to the active illumination source and the camera sensor. A model for jitter is presented and is used to characterise the jitter in a real camera system. Correction of the effects of jitter in real acquired range images is demonstrated by a reduction of the standard deviation of random noise by up to a factor of five, with the best reductions occurring in pixels that receive a strong signal.
  • Item type:Publication,
    Application of lidar techniques to time-of-flight range imaging
    2015, OPTICAL SOC AMER
    Amplitude modulated continuous wave (AMCW) time-of flight (ToF) range imaging cameras measure distance by illuminating the scene with amplitude modulated light and measuring the phase difference between the transmitted and reflected modulation envelope. This method of optical range measurement suffers from errors caused by multiple propagation paths, motion, phase wrapping and non-ideal amplitude modulation. In this paper a ToF camera is modified to operate in modes analogous to continuous wave (CW) and stepped frequency continuous wave (SFCW) lidar. In CW operation the velocity of objects can be measured. CW measurement of velocity was linear with true velocity (R² = 0.9969). Qualitative analysis of a complex scene confirms that range measured by SFCW is resilient to errors caused by multiple propagation paths, phase wrapping and non-ideal amplitude modulation which plague AMCW operation. In viewing a complicated scene through a translucent sheet, quantitative comparison of AMCW with SFCW demonstrated a reduction in the median error from −1.3 m to −0.06 m with inter-quartile range of error reduced from 4.0 m to 0.18 m.
  • Item type:Publication,
    Extracting the MESA SR4000 Calibrations
    2015, SPIE
    Time-of-flight range imaging cameras are capable of acquiring depth images of a scene. Some algorithms require these cameras to be run in `raw mode', where any calibrations from the off-the-shelf manufacturers are lost. The calibration of the MESA SR4000 is herein investigated, with an attempt to reconstruct the full calibration. Possession of the factory calibration enables calibrated data to be acquired and manipulated even in “raw mode.” This work is motivated by the problem of motion correction, in which the calibration must be separated into component parts to be applied at different stages in the algorithm. There are also other applications, in which multiple frequencies are required, such as multipath interference correction. The other frequencies can be calibrated in a similar way, using the factory calibration as a base. A novel technique for capturing the calibration data is described; a retro-reflector is used on a moving platform, which acts as a point source at a distance, resulting in planar waves on the sensor. A number of calibrations are retrieved from the camera, and are then modelled and compared to the factory calibration. When comparing the factory calibration to both the “raw mode” data, and the calibration described herein, a root mean squared error improvement of 51:3mm was seen, with a standard deviation improvement of 34:9mm. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
  • Item type:Publication,
    Design of a Pseudo-Holographic Distributed Time-of-Flight Sonar Range-Imaging System
    2016, IEEE
    The design of an audible sonar distributed sensor time-of-flight range imaging system is investigated, sonar being chosen as a substitute for optical range imaging due to cost and simplicity of implementation. The distributed range imaging system proposed is based on the holographic principle where the sensors detect the self interference of the reflected sound from the scene, and the Fourier analysis computes the reflected object profile. An approximate linearised model used in related holographic imaging techniques is found to be inappropriate for the design, and qualitative assessment of simulations show that removing the linearisation dramatically improves image reconstruction. Quantitatively the nonlinear reconstruction improves the RMSE by a factor of 1.3-2.1 times. The full nonlinear reconstruction is slow, and mathematical development lead to 15 fold reduction in computation time.