<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

University of Waikato Research

Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288

Browse

Search Results

Now showing 1 - 5 of 5
  • Item type:Publication,
    Non-linear time domain model of electropermeabilization: Effect of extracellular conductivity and applied electric field parameters
    2008, Elsevier
    This paper describes simulation results obtained from a previously reported numerical model for a single cell exposed to an arbitrary waveform electric field pulse. This paper concentrates on how the efficiency of electroporation related applications can be significantly improved by appropriately adjusting the parameters of applied electric field and conductivity of the external medium, σe. Emphasis is given here on the normalization of the degree of electroporation for a range of cell radii. The simulated results indicate that it may be difficult for cells of substantially different sizes to be close to uniformly electroporated if surrounded by media with a conductivity higher than around 5*10⁻³ S/m for 100 kHz bipolar pulses, or 0.2 S/m for 1 MHz bipolar pulses. To achieve as normalized as possible electroporation for the radii/size variation required in any particular application, using a lower σe would be preferable. There is, however, a limit to how low the external conductivity can be made, as the applied electric field amplitude must stay within practical limits. Considering 3*10¹³ pores/m² as a nominal pore density N for approximately optimum electroporation, σe could be as low as 0.08 S/m for a 7.5 µm cell radius with a peak electric field of 1.2*10⁵V/m (depending on the pulse shape and frequency). For a 15 µm cell radius, σe could be as low as 0.05 S/m (depending on the pulse shape and frequency). It is seen that the relative difference of N between the two cell sizes investigated is consistently lower for a bipolar sine wave electric field compared to a bipolar square wave electric field, even though the square wave electric field peak amplitude is always lower for an equivalent N.
  • Item type:Publication,
    Phase-polarisation contrast for surface plasmon resonance based on low cost grating substrates
    2008, Elsevier
    This paper presents a new grating configuration that combines the benefits of multi-angle interrogation with the phase-polarisation contrast method. The setup is based on the gold grating of a commercially available recordable compact disk, which allows the excitation of surface plasmons. The compact disks are mass produced by injection-moulding, which results in low cost disposable grating substrates. The measurement method allows high resolution analysis of gases and surface chemistry. Results for this system have been demonstrated using helium, air and carbon dioxide gases.
  • Item type:Publication,
    Drug delivery by electroporation: Review
    2013, Springer-Verlag
    Drug delivery is the method or process of administering a pharmaceutical compound to achieve a therapeutic effect in humans or animals. Most common routes of administration include the preferred non-invasive peroral (through the mouth), topical (skin), transmucosal (nasal, buccal/sublingual, vaginal, ocular and rectal) and inhalation routes. Current effort in the area of drug delivery include the development of targeted delivery in which the drug is only active in the target area of the body (for example, in cancerous tissues) and sustained release formulations in which the drug is released over a period of time in a controlled manner from a formulation. This is achieved by combining electroporation with the input of drugs at a location. This paper reviews the process of electroporation and then further discusses the electrochemotherapy, one of the most upcoming application of electroporation in biotechnology.
  • Item type:Publication,
    Wine maturation using high electric field
    2013, Springer-Verlag
    Wine maturation can take a long time and consumes storage space which can be a drawback while considering commercial aspect of wine making. In the past scientists have carried out experiments on maturing wine quickly using ultrasounds or gamma radiations. This study reports about maturing wine with high electric field at different frequencies applied for a short time duration. The electric field intensity and the frequency of the field along with the exposure time of wine to this field seem to be important parameters that could affect the the treated wine. Results obtained are encouraging and have a potential for commercial interest.
  • Item type:Publication,
    Modelling single cell electroporation with bipolar pulse: Simulating dependance of electroporated fractional pore area on the bipolar field frequency
    2010, SpringerLink
    Electroporation EP, in which external electric field pulses create transient pores in a cell membrane, is an important technique for delivery of DNA and drugs into the cell. To enable entry of DNA into cells, the pores should have sufficiently large radii, remain open long enough for the DNA chain to enter the cell, and should not cause membrane rupture. A numerical model for a single spherical cell electroporated by application of direct and/or alternating external electric field pulses has been developed. The model is used to calculate the transmembrane potential, the number of pores and the the fraction of area occupied by the pores (fractional pore area FPA) in response to the various electric field pulses. Presented here are simulation results used to compare the extent of electroporation (fractional pore area FPA) in response to eletric field pulses of different frequencies in a range of extracellular conductivity for two cell raii. It is also observed that a 1 MHz bipolar sinusoidal applied electric field pulse reduces the relative difference in fractional pore area between the two cell sizes compared to a 100 kHz pulse.