<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

University of Waikato Research

Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288

Browse

Search Results

Now showing 1 - 3 of 3
  • Item type:Publication,
    Non-linear time domain model of electropermeabilization: Effect of extracellular conductivity and applied electric field parameters
    2008, Elsevier
    This paper describes simulation results obtained from a previously reported numerical model for a single cell exposed to an arbitrary waveform electric field pulse. This paper concentrates on how the efficiency of electroporation related applications can be significantly improved by appropriately adjusting the parameters of applied electric field and conductivity of the external medium, σe. Emphasis is given here on the normalization of the degree of electroporation for a range of cell radii. The simulated results indicate that it may be difficult for cells of substantially different sizes to be close to uniformly electroporated if surrounded by media with a conductivity higher than around 5*10⁻³ S/m for 100 kHz bipolar pulses, or 0.2 S/m for 1 MHz bipolar pulses. To achieve as normalized as possible electroporation for the radii/size variation required in any particular application, using a lower σe would be preferable. There is, however, a limit to how low the external conductivity can be made, as the applied electric field amplitude must stay within practical limits. Considering 3*10¹³ pores/m² as a nominal pore density N for approximately optimum electroporation, σe could be as low as 0.08 S/m for a 7.5 µm cell radius with a peak electric field of 1.2*10⁵V/m (depending on the pulse shape and frequency). For a 15 µm cell radius, σe could be as low as 0.05 S/m (depending on the pulse shape and frequency). It is seen that the relative difference of N between the two cell sizes investigated is consistently lower for a bipolar sine wave electric field compared to a bipolar square wave electric field, even though the square wave electric field peak amplitude is always lower for an equivalent N.
  • Item type:Publication,
    Modelling single cell electroporation with bipolar pulse: Simulating dependance of electroporated fractional pore area on the bipolar field frequency
    2010, SpringerLink
    Electroporation EP, in which external electric field pulses create transient pores in a cell membrane, is an important technique for delivery of DNA and drugs into the cell. To enable entry of DNA into cells, the pores should have sufficiently large radii, remain open long enough for the DNA chain to enter the cell, and should not cause membrane rupture. A numerical model for a single spherical cell electroporated by application of direct and/or alternating external electric field pulses has been developed. The model is used to calculate the transmembrane potential, the number of pores and the the fraction of area occupied by the pores (fractional pore area FPA) in response to the various electric field pulses. Presented here are simulation results used to compare the extent of electroporation (fractional pore area FPA) in response to eletric field pulses of different frequencies in a range of extracellular conductivity for two cell raii. It is also observed that a 1 MHz bipolar sinusoidal applied electric field pulse reduces the relative difference in fractional pore area between the two cell sizes compared to a 100 kHz pulse.
  • Item type:Publication,
    Modelling single cell electroporation with bipolar pulse parameters and dynamic pore radii
    2010, Elsevier
    We develop a model of single spherical cell electroporation and simulate spatial and temporal aspects of the transmembrane potential and pore radii as an effect of any form of applied electric field. The extent of electroporation in response to sinusoidal electric pulses of two different frequencies in a range of extracellular conductivity for two different cell radii are compared. Results show that pore radii tend to be more normalized for AC fields. The relative difference in fractional pore area is reduced by the use of a 1 MHz sinusoidal applied electric field over a 100 kHz field.