<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

University of Waikato Research

Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288

Browse

Search Results

Now showing 1 - 7 of 7
  • Item type:Publication,
    Trophic state assessment of global inland waters using a MODIS-derived Forel-Ule index
    2018, Elsevier
    Eutrophication of inland waters is considered a serious global environmental problem. Satellite remote sensing (RS) has been established as an important source of information to determine the trophic state of inland waters through the retrieval of optically active water quality parameters such as chlorophyll-a (Chl-a). However, the use of RS techniques for assessment of the trophic state of inland waters on a global scale is hindered by the performance of retrieval algorithms over highly dynamic and complex optical properties that characterize many of these systems. In this study, we developed a new RS approach to assess the trophic state of global inland water bodies based on Moderate Resolution Imaging Spectroradiometer (MODIS) imagery and the Forel-Ule index (FUI). First, the FUI was calculated from MODIS data by dividing natural water colour into 21 indices from dark blue to yellowish-brown. Then the relationship between FUI and the trophic state index (TSI) was established based on in-situ measurements and MODIS products. The water-leaving reflectance at 645 nm band was employed to distinguish coloured dissolved organic matter (CDOM)-dominated systems in the FUI-based trophic state assessment. Based on the analysis, the FUI-based trophic state assessment method was developed and applied to assess the trophic states of 2058 large inland water bodies (surface area >25 km2) distributed around the world using MODIS data from the austral and boreal summers of 2012. Our results showed that FUI can be retrieved from MODIS with a considerable accuracy (92.5%, R2 = 0.92) by comparing with concurrent in situ measurements over a wide range of lakes, and the overall accuracy of the FUI-based trophic state assessment method is 80.0% (R2 = 0.75) validated by an independent dataset. Of the global large water bodies considered, oligotrophic large lakes were found to be concentrated in plateau regions in central Asia and southern South America, while eutrophic large lakes were concentrated in central Africa, eastern Asia, and mid-northern and southeast North America.
  • Item type:Publication,
    Ground Plane Segmentation of Time-of-Flight Images for Asparagus Harvesting
    2018, IEEE
    A key task in processing time-of-flight images for the detection of asparagus spears is the identification and segmentation of the ground plane. In this paper, we aim to compare the performance of RANSAC with a modified version of an existing deterministic method, namely Hyun’s method. Each method is tested on scenes with varying amounts of field clutter. Additionally, a variety of camera angles are investigated. We find that both RANSAC and the proposed method produce ground plane predictions with a root mean square error of less than 0.05m and execute at a rate of approximately 0.056s per frame. However, RANSAC was shown to be much less reliable in high clutter scenes. The camera mounting angle is found to significantly affect the density and noise of points in time-of-flight images. These factors translate to significantly worse performance for both methods at low camera angles.
  • Item type:Publication,
    Hidden features: Experiments with feature transfer for fine-grained multi-class and one-class image categorization
    2018, IEEE
    Can we apply out-of-the box feature transfer using pre-trained convolutional neural networks in fine-grained multiclass image categorization tasks? What is the effect of (a) domainspecific fine-tuning and (b) a special-purpose network architecture designed and trained specifically for the target domain? How do these approaches perform in one-class classification? We investigate these questions by tackling two biological object recognition tasks: classification of “cryptic” plants of genus Coprosma and identification of New Zealand moth species. We compare results based on out-of-the-box features extracted using a pre-trained state-of-the-art network to those obtained by finetuning to the target domain, and also evaluate features learned using a simple Siamese network trained only on data from the target domain. For each extracted feature set, we test a number of classifiers, e.g., support vector machines. In addition to multiclass classification, we also consider one-class classification, a scenario that is particularly relevant to biosecurity applications. In the multi-class setting, we find that out-of-the-box lowlevel features extracted from the generic pre-trained network yield high accuracy (90.76%) when coupled with a simple LDA classifier. Fine-tuning improves accuracy only slightly (to 91.6%). Interestingly, features extracted from the much simpler Siamese network trained on data from the target domain lead to comparable results (90.8%). In the one-class classification setting, we note high variability in the area under the ROC curve across feature sets, opening up the possibility of considering an ensemble approach.
  • Item type:Publication,
    Signal processing approaches for Jitter extraction in time-of-flight range imaging cameras
    2018, IEEE
    The precision and accuracy of time-of-flight full-field range cameras are important for many applications, however there are a number of noise sources that degrade both precision and accuracy. Many of the noise sources such as nonlinearity, multipath inferences and harmonic cancellation are well investigated. Barely investigated is jitter on the camera light and shutter signals. Here we measure periodic and random jitter on the light signal of a camera. We use signal processing techniques to construct a reference signal, hence find the jitter. The performance of the proposed method is examined using the MESA Imaging SwissRanger 4000. We found periodic jitter of two frequencies at 0.12 and 5.04 MHz and the random jitter of 164 ± 4 ps, on the light signal of the camera.
  • Item type:Publication,
    A strategy for the correction of effects of jitter in AMCW lidar images
    2013, IEEE
    Full-field range imaging cameras, which are an example of amplitude modulated continuous wave (AMCW) lidar, are subject to multiple error sources. In this paper we consider the possibility that a global jitter and/or drift occurs between the modulation signals to the active illumination source and the camera sensor. A model for jitter is presented and is used to characterise the jitter in a real camera system. Correction of the effects of jitter in real acquired range images is demonstrated by a reduction of the standard deviation of random noise by up to a factor of five, with the best reductions occurring in pixels that receive a strong signal.
  • Item type:Publication,
    Extracting the MESA SR4000 Calibrations
    2015, SPIE
    Time-of-flight range imaging cameras are capable of acquiring depth images of a scene. Some algorithms require these cameras to be run in `raw mode', where any calibrations from the off-the-shelf manufacturers are lost. The calibration of the MESA SR4000 is herein investigated, with an attempt to reconstruct the full calibration. Possession of the factory calibration enables calibrated data to be acquired and manipulated even in “raw mode.” This work is motivated by the problem of motion correction, in which the calibration must be separated into component parts to be applied at different stages in the algorithm. There are also other applications, in which multiple frequencies are required, such as multipath interference correction. The other frequencies can be calibrated in a similar way, using the factory calibration as a base. A novel technique for capturing the calibration data is described; a retro-reflector is used on a moving platform, which acts as a point source at a distance, resulting in planar waves on the sensor. A number of calibrations are retrieved from the camera, and are then modelled and compared to the factory calibration. When comparing the factory calibration to both the “raw mode” data, and the calibration described herein, a root mean squared error improvement of 51:3mm was seen, with a standard deviation improvement of 34:9mm. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
  • Item type:Publication,
    Design of a Pseudo-Holographic Distributed Time-of-Flight Sonar Range-Imaging System
    2016, IEEE
    The design of an audible sonar distributed sensor time-of-flight range imaging system is investigated, sonar being chosen as a substitute for optical range imaging due to cost and simplicity of implementation. The distributed range imaging system proposed is based on the holographic principle where the sensors detect the self interference of the reflected sound from the scene, and the Fourier analysis computes the reflected object profile. An approximate linearised model used in related holographic imaging techniques is found to be inappropriate for the design, and qualitative assessment of simulations show that removing the linearisation dramatically improves image reconstruction. Quantitatively the nonlinear reconstruction improves the RMSE by a factor of 1.3-2.1 times. The full nonlinear reconstruction is slow, and mathematical development lead to 15 fold reduction in computation time.