University of Waikato Research
Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288
Browse
22 results
Search Results
Item type:Publication, Simultaneous phase and frequency stepping in Time-of-flight range imaging2019, IEEETime-of-flight (ToF) range imaging is an established full-field depth acquisition technology. ToF is prone to several forms of error, notably multi-path interference (MPI). Frequency stepping ToF mitigates these errors, but efficient computational methods suffer from bandwidth limitations. We introduce a new acquisition method based on simultaneous phase and frequency stepping, which is capable of running in real time and reduces error compared to phase stepping and frequency stepping alone.Item type:Publication, Resolving Multiple Propagation Paths in Time of Flight Range Cameras using Direct and Global Separation Methods2015, SPIETime of flight (ToF) range cameras illuminate the scene with an amplitude-modulated continuous wave light source and measure the returning modulation envelopes: phase and amplitude. The phase change of the modulation envelope encodes the distance travelled. This technology suffers from measurement errors caused by multiple propagation paths from the light source to the receiving pixel. The multiple paths can be represented as the summation of a direct return, which is the return from the shortest path length, and a global return, which includes all other returns. We develop the use of a sinusoidal pattern from which a closed form solution for the direct and global returns can be computed in nine frames with the constraint that the global return is a spatially lower frequency than the illuminated pattern. In a demonstration on a scene constructed to have strong multipath interference, we find the direct return is not significantly different from the ground truth in 33∕136 pixels tested; where for the full-field measurement, it is significantly different for every pixel tested. The variance in the estimated direct phase and amplitude increases by a factor of eight compared with the standard time of flight range camera technique.Item type:Publication, Analysis of the SoftKinetic DepthSense for Range Imaging2013, SpringerWe analyse the SoftKinetic DepthSense 325 range imaging camera for precision and accuracy in ranging out to 3 m. Flat planar targets (one a grey board, the other made from retroreflective material) are imaged at a variety of distances. Straight-forward image processing is used to identify the target and calculate the range and the root mean square variation in ranging to the target. It is found that inaccuracies in ranging of up to 2 cm occur to the grey board when imaging over 0 m to 1.5 m and the precision in ranging degrades from just below 1 cm at 0 m to almost 10 cm at 1.5 m. Similar inaccuracies occur with the retroreflective target but the precision is always under 1 cm even out to 3 m due to the strong signal return received from the target.Item type:Publication, Closed-form inverses for the mixed pixel/multipath interference problem in AMCW lidar2012, SPIEWe present two new closed-form methods for mixed pixel/multipath interference separation in AMCW lidar systems. The mixed pixel/multipath interference problem arises from the violation of a standard range-imaging assumption that each pixel integrates over only a single, discrete backscattering source. While a numerical inversion method has previously been proposed, no close-form inverses have previously been posited. The first new method models reflectivity as a Cauchy distribution over range and uses four measurements at different modulation frequencies to determine the amplitude, phase and reflectivity distribution of up to two component returns within each pixel. The second new method uses attenuation ratios to determine the amplitude and phase of up to two component returns within each pixel. The methods are tested on both simulated and real data and shown to produce a significant improvement in overall error. While this paper focusses on the AMCW mixed pixel/multipath interference problem, the algorithms contained herein have applicability to the reconstruction of a sparse one dimensional signal from an extremely limited number of discrete samples of its Fourier transform.Item type:Publication, A power-saving modulation technique for time-of-flight range imaging sensors2011, Society of Photo-Optical Instrumentation EngineersTime-of-flight range imaging cameras measure distance and intensity simultaneously for every pixel in an image. With the continued advancement of the technology, a wide variety of new depth sensing applications are emerging; however a number of these potential applications have stringent electrical power constraints that are difficult to meet with the current state-of-the-art systems. Sensor gain modulation contributes a significant proportion of the total image sensor power consumption, and as higher spatial resolution range image sensors operating at higher modulation frequencies (to achieve better measurement precision) are developed, this proportion is likely to increase. The authors have developed a new sensor modulation technique using resonant circuit concepts that is more power efficient than the standard mode of operation. With a proof of principle system, a 93–96% reduction in modulation drive power was demonstrated across a range of modulation frequencies from 1–11 MHz. Finally, an evaluation of the range imaging performance revealed an improvement in measurement linearity in the resonant configuration due primarily to the more sinusoidal shape of the resonant electrical waveforms, while the average precision values were comparable between the standard and resonant operating modes.Item type:Publication, Illumination waveform optimization for time-of-flight range imaging cameras2011, Society of Photo-Optical Instrumentation EngineersTime-of-flight range imaging sensors acquire an image of a scene, where in addition to standard intensity information, the range (or distance) is also measured concurrently by each pixel. Range is measured using a correlation technique, where an amplitude modulated light source illuminates the scene and the reflected light is sampled by a gain modulated image sensor. Typically the illumination source and image sensor are amplitude modulated with square waves, leading to a range measurement linearity error caused by aliased harmonic components within the correlation waveform. A simple method to improve measurement linearity by reducing the duty cycle of the illumination waveform to suppress problematic aliased harmonic components is demonstrated. If the total optical power is kept constant, the measured correlation waveform amplitude also increases at these reduced illumination duty cycles. Measurement performance is evaluated over a range of illumination duty cycles, both for a standard range imaging camera configuration, and also using a more complicated phase encoding method that is designed to cancel aliased harmonics during the sampling process. The standard configuration benefits from improved measurement linearity for illumination duty cycles around 30%, while the measured amplitude, hence range precision, is increased for both methods as the duty cycle is reduced below 50% (while maintaining constant optical power).Item type:Publication, Volume measurement using 3D Range Imaging2010, School of Engineering, The University of WaikatoThe use of 3D Range Imaging has widespread applications. One of its applications provides us the information about the volumes of different objects. In this paper, 3D range imaging has been utilised to find out the volumes of different objects using two algorithms that are based on a straightforward means to calculate volume. The algorithms implemented succesfully calculate volume on objects provided that the objects have uniform colour. Objects that have multi-coloured and glossy surfaces provided particular difficulties in determining volume.Item type:Publication, Proof of concept of diffuse optical tomography using time-of-flight range imaging cameras2010, School of Engineering, The University of WaikatoDiffuse optical tomography is an optical technique to create 3-dimensional images of the inside of highly scattering material. Research groups around the world have been developing imaging systems using various source-detector arrangements to determine optical properties of biological tissue with a focus on medical applications. In this paper we investigate whether a range imaging camera can be used as a detector array. We used time-of-flight range imaging cameras instead of the conventional source-detector array used by others. The results provided in this paper show reconstructed images of absorption and reduced scattering of an object submerged in a tissue simulating phantom. Using the ranging camera XZ422 Demonstrator and the NIRFAST software package, we reconstructed 2D images of a 6 mm metal rod submerged in the centre of a 5 cm deep tank filled with 1% IntralipidTM. We have shown for the first time that range imaging cameras can replace the traditional detectors in diffuse optical tomography.Item type:Publication, Advantages of 3D time-of-flight range imaging cameras in machine vision applications2009, Electronics ResearchMachine vision using image processing of traditional intensity images is in wide spread use. In many situations environmental conditions or object colours or shades cannot be controlled, leading to difficulties in correctly processing the images and requiring complicated processing algorithms. Many of these complications can be avoided by using range image data, instead of intensity data. This is because range image data represents the physical properties of object location and shape, practically independently of object colour or shading. The advantages of range image processing are presented, along with three example applications that show how robust machine vision results can be obtained with relatively simple range image processing in real-time applications.Item type:Publication, Maximizing precision over extended unambiguous range for TOF range imaging systems2010, IEEEThe maximum unambiguous range for time-of-flight range imaging systems is inversely proportional to the chosen modulation frequency. However, increasing the unambiguous range by decreasing the modulation frequency will generally also degrade the range measurement precision. We describe a technique that significantly extends the range of a time-of-flight imaging system without compromising range precision. This is achieved by employing two modulation frequencies simultaneously. The chosen frequencies can be a combination of high and low frequency, or two similarly high frequencies. In this paper we present experimental results comparing single frequency; dual high and low frequency; and dual high frequency operation and demonstrate that range precision need not be appreciably compromised to achieve an extended unambiguous range.