<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

A derivative method for minimising total cost in heat exchanger networks through optimal area allocation

dc.contributor.authorWalmsley, Timothy G.
dc.contributor.authorWalmsley, Michael R. W.
dc.contributor.authorMorrison, Andrew S.
dc.contributor.authorAtkins, Martin John
dc.contributor.authorNeale, James R.
dc.coverage.spatialRhodes, Greeceen_NZ
dc.date.accessioned2014-03-07T00:55:58Z
dc.date.available2014-03-07T00:55:58Z
dc.date.issued2013
dc.description.abstractThis paper presents a novel Cost Derivative Method (CDM) for finding the optimal area allocation for a defined Heat Exchanger Network (HEN) structure and stream data, without any stream splits to achieve minimum total cost. Using the Pinch Design Method (PDM) to determine the HEN structure, the approach attempts to add, remove and shift area to exchangers where economic benefits are returned. From the derivation of the method, it is found that the slope of the ε-NTU relationship for the specific heat exchanger type, in combination with the difference in exchanger inlet temperatures and the overall heat transfer coefficient, are critical to calculating the extra overall duty each incremental area element returns. The approach is able to account for differences in film coefficients, heat exchanger types, flow arrangements, exchanger cost functions, and utility pricing. Incorporated into the method is the newly defined “utility cost savings flow-on” factor, θ, which evaluates downstream effects on utility use and cost that are caused by changing the area of one exchanger. To illustrate the method, the CDM is applied to the distillation example of Gundersen (2000). After applying the new CDM, the total annual cost was reduced by 7.1 % mainly due to 24 % less HEN area for similar heat recovery. Area reduction resulted from one exchanger having a minimum approach temperature (ΔTmin) of 7.7 °C while the other recovery exchangers had larger ΔTmin values. The optimum ΔTmin for the PDM was 12.5 °C. The CDM solution was found to give a comparable minimum total area and cost to two recently published programming HEN synthesis solutions for the same problem without requiring the increased network complexity through multiple stream splits.en_NZ
dc.format.mimetypeapplication/pdf
dc.identifier.citationWalmsley, T. G., Walmsley, M. R. W., Morrison, A. S., Atkins, M. J., & Neale, J. R. (2013). A derivative method for minimising total cost in heat exchanger networks through optimal area allocation. Chemical Engineering Transactions, 35, 1171-1176.en_NZ
dc.identifier.doi10.3303/CET1335195en_NZ
dc.identifier.urihttps://hdl.handle.net/10289/8550
dc.language.isoenen_NZ
dc.publisherAIDICen_NZ
dc.relation.isPartOfChemical Engineering Transactionsen_NZ
dc.relation.urihttp://www.aidic.it/cet/13/35/195.pdfen_NZ
dc.rightsThis article has been published in the journal: Chemical Engineering Transactions. © 2013 AIDIC. Used with permission.en_NZ
dc.subjectCost Derivative Methoden_NZ
dc.titleA derivative method for minimising total cost in heat exchanger networks through optimal area allocationen_NZ
dc.typeJournal Articleen_NZ
dspace.entity.typePublication
pubs.begin-page1171en_NZ
pubs.end-page1176en_NZ
pubs.volume35en_NZ

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
A derivative method.pdf
Size:
167.42 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: