Simple harmonic error cancellation in time of flight range imaging

Loading...
Thumbnail Image

Publisher link

Rights

This is an author’s accepted version of an article published in the journal: Optics Letters. © 2015 Optical Society of America.

Abstract

Amplitude modulated continuous wave (AMCW) time of flight (ToF) range imaging provides a full field of distance measurement, but common hardware is implemented with digital technology which leads to unwanted harmonic content, a principle source of error in the distance measurements. Existing strategies for correction of harmonics require auxiliary measurements and amplify noise. A small modification of the data acquisition procedure is described which, intrinsically, is invariant to at least one harmonic. The third harmonic, the main cause of harmonic error, is targeted. Compared to traditional measurements the third harmonic is eliminated with no significant increase in noise variance observed.

Citation

Streeter, L. V., & Dorrington, A. A. (2015). Simple harmonic error cancellation in time of flight range imaging. Optics Letters, 40(22), 5391–5391. https://doi.org/10.1364/OL.40.005391

Series name

Date

Publisher

OAS Publishing

Degree

Type of thesis

Supervisor