<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

Relating bridge analysis for heat exchanger network retrofit identification to retrofit design

dc.contributor.authorWalmsley, Timothy G.en_NZ
dc.contributor.authorLal, Nathan S.en_NZ
dc.contributor.authorVarbanov, Petar S.en_NZ
dc.contributor.authorKlemeš, Jiří Jaromíren_NZ
dc.date.accessioned2019-12-18T21:06:05Z
dc.date.available2018-01-01en_NZ
dc.date.available2019-12-18T21:06:05Z
dc.date.issued2018en_NZ
dc.description.abstractThe aim of the paper is to improve a recently developed automated HEN retrofit targeting method by linking the shapes of the Exchanger Shifted Composite Curve (ESCC) and Exchanger Grand Composite Curve (EGCC) to the required HEN retrofit design measures. The automated HEN retrofit targeting method is based on Bridge Analysis, which identifies new and existing utility paths for energy saving through the enhancement and/or addition of heat exchanger area and the installation of new exchangers. To build the required understanding, generic cases are analysed, one of which is presented. Links between the Exchanger Composite Curves with the required HEN retrofit design are established. The analysis concludes that the Heat Surplus-Deficit Cascade for some recovery exchangers may be divided two sections – Pinched and non-Pinched sections – to better represent and identify the number and type of modifications that a retrofit opportunity will require.en_NZ
dc.format.mimetypeapplication/pdf
dc.identifier.citationWalmsley, T. G., Lal, N. S., Varbanov, P. S., & Klemeš, J. Jj. (2018). Relating bridge analysis for heat exchanger network retrofit identification to retrofit design. Chemical Engineering Transactions, 70, 295–300. https://doi.org/10.3303/CET1870050en
dc.identifier.doi10.3303/CET1870050en_NZ
dc.identifier.eissn2283-9216en_NZ
dc.identifier.urihttps://hdl.handle.net/10289/13334
dc.language.isoen
dc.publisherAIDIC Servizi S.r.l.
dc.relation.isPartOfChemical Engineering Transactionsen_NZ
dc.relation.urihttps://www.cetjournal.it/index.php/cet/article/view/CET1870050
dc.rightsCopyright © 2018, AIDIC Servizi S.r.l. Used with permission.
dc.titleRelating bridge analysis for heat exchanger network retrofit identification to retrofit designen_NZ
dc.typeJournal Article
dspace.entity.typePublication
pubs.begin-page295
pubs.end-page300
pubs.publication-statusPublisheden_NZ
pubs.volume70en_NZ

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
050.pdf
Size:
1.2 MB
Format:
Adobe Portable Document Format
Description:
Published version

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Research Commons Deposit Agreement 2017.pdf
Size:
188.11 KB
Format:
Adobe Portable Document Format
Description: