      Extracting the MESA SR4000 Calibrations

      Charleston, Sean A.; Dorrington, Adrian A.; Streeter, Lee; Cree, Michael J.
      Thumbnail
      Files
      pspie-article-charleston-etal-v9528-p95280S-2015.pdf
      Published version, 374.5Kb
      DOI
       10.1117/12.2183654
      Find in your library  
      Citation
      Export citation
      Charleston, S. A., Dorrington, A. A., Streeter, L., & Cree, M. J. (2015). Extracting the MESA SR4000 Calibrations. In F. Remondino & M. R. Shortis (Eds.), Videometrics, Range Imaging, and Applications XIII (Vol. 9528). Munich, Germany: SPIE. https://doi.org/10.1117/12.2183654
      Permanent Research Commons link: https://hdl.handle.net/10289/11211
      Abstract
      Time-of-flight range imaging cameras are capable of acquiring depth images of a scene. Some algorithms require these cameras to be run in `raw mode', where any calibrations from the off-the-shelf manufacturers are lost. The calibration of the MESA SR4000 is herein investigated, with an attempt to reconstruct the full calibration. Possession of the factory calibration enables calibrated data to be acquired and manipulated even in “raw mode.” This work is motivated by the problem of motion correction, in which the calibration must be separated into component parts to be applied at different stages in the algorithm. There are also other applications, in which multiple frequencies are required, such as multipath interference correction. The other frequencies can be calibrated in a similar way, using the factory calibration as a base. A novel technique for capturing the calibration data is described; a retro-reflector is used on a moving platform, which acts as a point source at a distance, resulting in planar waves on the sensor. A number of calibrations are retrieved from the camera, and are then modelled and compared to the factory calibration. When comparing the factory calibration to both the “raw mode” data, and the calibration described herein, a root mean squared error improvement of 51:3mm was seen, with a standard deviation improvement of 34:9mm. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
      Date
      2015
      Type
      Conference Contribution
      Publisher
      SPIE
      Rights
      © 2015 SPIE
      Collections
      • Science and Engineering Papers [3116]
      Show full item record  

      Usage

      Downloads, last 12 months
      115
       
       
       

      Usage Statistics

      For this itemFor all of Research Commons

      The University of Waikato - Te Whare Wānanga o WaikatoFeedback and RequestsCopyright and Legal Statement