      Reliability of a 2-Bout exercise test on a Wattbike cycle ergometer

      Driller, Matthew W.; Argus, Christos K.; Bartram, Jason C.; Bonaventura, Jacinta; Martin, David T.; West, Nicholas P.; Halson, Shona L.
      Thumbnail
      Files
      Reliability.pdf
      113.0Kb
      DOI
       10.1123/ijspp.2013-0103
      Find in your library  
      Citation
      Export citation
      Driller, M., Argus, C., Bartram, J., Bonaventura, J., Martin, D., West, N., & Halson, S. (2014). Reliability of a 2-Bout exercise test on a Wattbike cycle ergometer. IJSPP, 9(2), 340-345.
      Permanent Research Commons link: https://hdl.handle.net/10289/8540
      Abstract
      Purpose: To determine the intraday and interday reliability of a 2 × 4-min performance test on a cycle ergometer (Wattbike) separated by 30 min of passive recovery (2 × 4MMP). Methods: Twelve highly trained cyclists (mean ± SD; age = 20 ± 2 y, predicted VO2max = 59.0 ± 3.6 mL · kg–1 · min–1) completed six 2 × 4MMP cycling tests on a Wattbike ergometer separated by 7 d. Mean power was measured to determine intraday (test 1 [T1] to test 2 [T2]) and interday reliability (weeks 1–6) over the repeated trials. Results: The mean intraday reliabilities of the 2 × 4MMP test, as expressed by the typical error of measurement (TEM, W) and coefficient of variation (CV, %) over the 6 wk, were 10.0 W (95% confidence limits [CL] 8.2–11.8), and 2.6% (95%CL 2.1–3.1), respectively. The mean interday reliability TEM and CV for T1 over the 6 wk were 10.4 W (95%CL 8.7–13.3) and 2.7% (95%CL 2.3–3.5), respectively, and 11.7 W (95%CL 9.8–15.1) and 3.0% (95%CL 2.5–3.9) for T2. Conclusion: The testing protocol performed on a Wattbike cycle ergometer in the current study is reproducible in highly trained cyclists. The high intraday and interday reliability make it a reliable method for monitoring cycling performance and for investigating factors that affect performance in cycling events.
      Date
      2014
      Type
      Journal Article
      Rights
      © 2014 Human Kinetics, Inc.