University of Waikato Research
Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288
Browse
7 results
Search Results
Item type:Publication, Integration of industrial solar and gaseous waste heat into heat recovery loops using constant and variable temperature storage2014, ElsevierSolar is a renewable energy that can be used to provide process heat to industrial sites but require thermal storage. HRLs (heat recovery loops) are an indirect method for transferring heat from one process to another using an intermediate fluid. With HRL's thermal storage is also necessary to effectively meet the stop/start time dependent nature of the multiple source and sink streams. Combining solar heating with HRL's is a cost effective way to share common storage and piping infrastructure. The conventional HRL design method based on a CTS (constant temperature storage) and a new HRL design method using VTS (variable temperature storage) are applied to demonstrate the potential benefits of inter-plant heat integration and installing solar heating. The dairy case study had available 12 source streams including four spray dryer exhausts and six sink streams. The addition of the dryer exhausts as heat sources was a critical factor in gaining a heat recovery of 10.8 MW for the variable temperature storage design, of which 5.1 MW was contributed from exhaust heat recovery. For the same minimum approach temperature the VTS approach achieved 37% more heat recovery compared to the CTS approach. Solar heating also proved to be a valuable source to be integrated into an HRL with a pinch around the cold storage tank with the maximum addition of 0.9 MW of heating on average for the CTS approach and 1.0 MW of heating on average for the VTS approach.Item type:Publication, Fouling and pressure drop analysis of milk powder deposition on the front of parallel fins2013, ElsevierOne method to reduce the energy consumption of industrial milk spray dryers is to recover waste heat from the exhaust dryer air. A significant challenge associated with this opportunity is the air contains a small amount of powder that may deposit on the face and surfaces of a recuperator. This paper introduces a novel lab based test that simulates powder deposition on a bank of parallel plate fins at exhaust dryer air conditions. The fin bank acts like the face of a typical finned tube row in a recuperator. The aim of this study is to look at how deposition on the front of fins is affected by the air conditions. Results show similar characteristics to other milk powder deposition studies that exhibit a dramatic increase in deposition once critical stickiness levels are reached. As powder deposits on the face of the fins, the pressure drop across the bank increases until eventually an asymptote occurs, at which point the rates of deposition and removal are similar. For very sticky conditions, deposition on the face of the fins can cause a rise in the pressure drop by as much as 65%. The pressure drop has also been successfully related to the percentage of open frontal area of the fins with and without deposition. Deposition inside and at the rear of the fin bank was found to be minimal.Item type:Publication, Improving energy recovery in milk powder production through soft data optimisation2013, ElsevierMilk powder production is highly energy intensive and can benefit from the application of Pinch analysis techniques to develop better methods for integrating the process. In this study, process stream data is extracted from an industrial plant and Pinch analysis applied to calculate utility and heat recovery targets. Some of process data is also varied, within small ranges that do not harm product quality or violate environmental regulation, to minimise utility use targets. Using the Pinch design method and the targets as a guide, Maximum Energy Recovery (MER) networks are developed for two cases, where the condenser in the evaporator section of the plant may be directly or indirectly integrating into the reminder of the process. The two MER networks are compared to two heat exchanger network structures commonly found in industry. Results show that there is potential to increase specific heat recovery by over 30%, while reducing total cost by almost 10%, in the best case. To achieve maximum energy recovery, spray dryer exhaust air heat recovery is necessary and should be matched to preheat the dryer inlet air stream.Item type:Publication, Methods for improving heat exchanger area distribution and storage temperature selection in heat recovery loops2013, ElsevierInter-plant Heat Integration across a large site can be achieved using a HRL (Heat Recovery Loop). In this paper the interrelationship between HRL storage temperatures, heat recovery and total HRL exchanger area is investigated. A methodology for designing a HRL based on a ΔTmin approach is compared to three programming optimisation approaches where heat exchangers are constrained to have the same NTU (Number of Heat Transfer Units), LMTD (Log-Mean Temperature Difference) or to find the absolute MTA (Minimum Total Area) for a given heat recovery level. Analysis is performed using time-averaged and transient mass flow rate data and temperature data. The actual temperature driving force of the HRL heat exchangers is compared to the apparent driving force as indicated by the Composite Curves. Results for the same heat recovery level show that the ΔTmin approach is effective at minimising total area to within 5% of the minimum area approach. Allocation of individual heat exchanger areas can vary widely depending on the optimisation method, the characteristics of the transient stream data and the differences in the approach and exit stream temperatures. Results suggest that using the ΔTmin method for selecting storage temperatures in combination with sizing exchangers based on the time average CP values (for while the process is running) gives a near optimal solution without requiring lots of data input or computing resourcesItem type:Publication, Process integration between individual plants at a large dairy factory by the application of heat recovery loops and transient stream analysis2012, ElsevierIndirect heat transfer between individual plants at a large industrial site, such as at a large dairy factory, can be accomplished using a Heat Recovery Loop (HRL) operating at relatively low temperatures (20–50 °C). Direct heat transfer between plants is problematic because of the production schedule and frequent process start-ups and shutdowns that occur due to the need for regular cleaning. The dynamic operation of an industrial HRL at a large dairy factory is presented and briefly discussed. A model HRL based on a set of variable industrial stream data is used to examine the effect of heat storage capacity and HRL temperature range on the amount of heat recovery. Both HRL temperature range and a small heat storage volume can significantly improve the amount of heat recovery. The interface level in the storage tank is also modelled for different volumes and the resulting system is very dynamic and therefore good control needs to be incorporated into the HRL.Item type:Publication, The effect of inlet conditions on the air side hydraulic resistance and flow maldistribution in industrial air heaters2011, ElsevierExperimental system hydraulic resistance measurements on a scale air heater unit have highlighted the excessive hydraulic resistance of typical industry configurations. Both poor header inlet conditions and large header expansion angles are shown to contribute to system hydraulic resistance magnitudes 20–100% higher than suitable benchmark cases. Typical centrifugal fan system efficiencies well under 80% multiply the system resistance effects resulting in larger fan power penalties. Velocity profile measurements taken upstream and downstream of the test heat exchanger under flow maldistribution conditions provide insight into the flow maldistribution spreading caused by the heat exchanger resistance. The anisotropic resistance of the plate fin-and-tube heat exchanger is shown to result in resistance induced flow dispersion being concentrated in the axis parallel to the plate fins.Item type:Publication, Compressed air system best practice programmes: What needs to change to secure long-term energy savings for New Zealand?2009, ElsevierThe establishment of a compressed air system (CAS) best practice programme is a key component of one of the initial industrial energy efficiency programmes being driven by New Zealand government ministries and agencies. In a global context this is not a new initiative in that existing programmes have been functioning in Europe and USA, yet in each of these cases the impact ten years-on has been patchy with limited long-term improvements in overall energy efficiency. The New Zealand CAS best practice programme currently under development is sponsored by the Electricity Commission (EC) and the Energy Efficiency Conservation Authority (EECA). It takes a new approach in policy direction, with variations from those used in other international programmes. A significant level of electricity levy money is to be committed to this programme and it is timely to highlight its merits and potential weaknesses, and what is required to generate long-term energy savings beyond the levels achieved by more mature overseas programmes.