<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

University of Waikato Research

Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288

Browse

Search Results

Now showing 1 - 10 of 17
  • Item type:Publication,
    Medical physics continuing professional development systems
    2013, Springer-Verlag
    Continuing professional development (CPD) is necessary for medical physicists to ensure that they are up to date with current clinical practice. Systems that monitor the CPD undertaken by medical physicists operate in 26 countries and are often used for certification, registration and license renewal purposes. They should be implemented in all countries where clinical medical physicists are employed. CPD is more than just continuing professional education (CPE). It can include research publication, working group contribution, thesis examination and many other activities. A survey of the CPD systems that are currently operated around the world shows that, in general, they are quite similar although are a few countries that have CPD systems that differ significantly from the others in many respects. Generally they ensure that medical physicists are kept up to date, although there are some that clearly will fail to achieve that. The different activities that are accepted as CPD were categorized. An analysis of what is required to construct a useful medical physics CPD system was made. The need for medical physicist professional organizations to cooperate and share in the production and distribution of CPD and CPE materials is explored. A higher level of international co-operation is recommended.
  • Item type:Publication,
    Monte Carlo evaluation of a Compton camera in breast and brain imaging
    2013, Springer
    Background: The Compton camera is increasingly becoming the subject of investigation for possible implementa- tion in nuclear medical imaging. It is likely to have advantages over Anger camera in medical imaging. However, very little has been done to characterize its performance for specific medical imaging techniques. There is therefore a need to fill in the gaps in knowledge relating to realistic evaluation of the viability of the camera for nuclear medical imaging. Objective: The present study has sought to explore the viability of a prototype Compton camera in breast and brain imaging. Methods: The GEANT4 simulation software was used to model the radiation transport and interactions with matter. Simulations were carried out of a Si/CZT Compton camera being used in breast and brain imaging. In order to study a challenging detection case, the volumes of two simulated breast tumours were chosen to be 0.65 mL, and embedded in the medial region of the breast. For the brain imaging, a multitracing approach was used, and imaging was done parallel to the orbitomeatal line of the brain. Results: The results suggest that the Compton camera would visualize small breast tumours of about 0.65 mL volume, placed at the medial region of an average compressed human breast. Although brain imaging using the Compton camera seems to be promising, analyses suggest however that beyond a distance difference of 2 cm between two brain tumours, there may be a need to rotate the camera around the human head for efficient brain imaging. Conclusions: It is envisioned that with further work, the Compton camera could replace the Anger camera in breast and brain imaging.
  • Item type:Publication,
    The international context of education, training and certification for medical physicists in Europe, North America and Australasia
    2013, Springer-Verlag
    A common international education, training and certification framework for medical physicists is not available. Because of this an agreed uniform level of skills and knowledge, which is considered as a prerequisite for the free movement of professionals, does not exist. The aim of this study is to provide a description of the present status of the medical physicist education, training and certification framework in 25 European, 2 North American and 2 Australasian countries and compare this with an international certification model. We find that a common policy is generally followed on education, training and certification as well as on professional practice, notwithstanding a few national differences. Attempts to formulate general guidelines are already in progress based on common features and differences between countries which could be used to inform the development of a truly international certification process for medical physicists.
  • Item type:Publication,
    A 2012 survey of the Australasian clinical medical physics and biomedical engineering workforce
    2013, Springer
    A survey of the medical physics and biomedical engineering workforce in Australia and New Zealand was carried out in 2012 following on from similar surveys in 2009 and 2006. 761 positions (equivalent to 736 equivalent full time (EFT) positions) were captured by the survey. Of these, 428 EFT were in radiation oncology physics, 63 EFT were in radiology physics, 49 EFT were in nuclear medicine physics, 150 EFT were in biomedical engineering and 46 EFT were attributed to other activities. The survey reviewed the experience profile, the salary levels and the number of vacant positions in the workforce for the different disciplines in each Australian state and in New Zealand. Analysis of the data shows the changes to the workforce over the preceding 6 years and identifies shortfalls in the workforce.
  • Item type:Publication,
    Continuing professional development systems for medical physicists: A global survey and analysis
    2012, Elsevier
    Continuing professional development (CPD) and continuing professional education (CPE) are seen as being necessary for medical physicists to ensure that they are up-to-date with current clinical practice. CPD is more than just continuing professional education, but can include research publication, working group contribution, thesis examination and many other activities. A systematic way of assessing and recording such activities that a medical physicist undertakes is used in a number of countries. This can be used for certification and licensing renewal purposes. Such systems are used in 27 countries, but they should be implemented in all countries where clinical medical physicists are employed. A survey of the CPD systems that are currently operated around the world is presented. In general they are quite similar although there are a few countries that have CPD systems that differ significantly from the others in many respects. Generally they ensure that medical physicists are kept up-to-date, although there are some that clearly will fail to achieve that. An analysis of what is required to construct a useful medical physics CPD system is made. Finally, the need for medical physicist professional organizations to cooperate and share in the production and distribution of CPD and CPE materials is emphasized.
  • Item type:Publication,
    AFOMP Policy Statement No. 4: Recommendations for continuing professional development systems for medical physicists in AFOMP countries
    2012, Springer-Verlag
    This policy statement, which is the fourth of a series of documents being prepared by the Asia-Oceania Federation of Organizations for Medical Physics Committees Professional Development Committee, gives guidance on how member countries could develop a continuing professional development system for ensuring that its clinical medical physicists are up-to-date in their knowledge and practice. It is not intended to be prescriptive as there are already several CPD systems successfully operated by AFOMP member countries and elsewhere that vary considerably in scope and structure according to local culture, practice and legislation but all of which are capable of ensuring that physicists are up-to-date. It is intended to be advisory and set out options for member countries to develop their individual CPD systems.
  • Item type:Publication,
    Evaluation of detector material and radiation source position on Compton camera’s ability for multitracer imaging
    2012, Springer
    We present a study on the effects of detector material, radionuclide source and source position on the Compton camera aimed at realistic characterization of the camera's performance in multitracer imaging as it relates to brain imaging. The GEANT4 Monte Carlo simulation software was used to model the physics of radiation transport and interactions with matter. Silicon (Si) and germanium (Ge) detectors were evaluated for the scatterer, and cadmium zinc telluride (CZT) and cerium-doped lanthanum bromide (LaBr3:Ce) were considered for the absorber. Image quality analyses suggest that the use of Si as the scatterer and CZT as the absorber would be preferred. Nevertheless, two simulated Compton camera models (Si/CZT and Si/LaBr3:Ce Compton cameras) that are considered in this study demonstrated good capabilities for multitracer imaging in that four radiotracers within the nuclear medicine energy range are clearly visualized by the cameras. It is found however that beyond a range difference of about 2 cm for In-113m and F-18 radiotracers in a brain phantom, there may be a need to rotate the Compton camera for efficient brain imaging.
  • Item type:Publication,
    Evaluation of two Compton camera models for scintimammography
    2011, Elsevier
    We study the performance of a Si/LaBr3:Ce Compton camera model for scintimammography, and compare it with a Si/NaI(Tl) model of similar geometry. The GEANT4 simulation toolkit was used to study the behaviour of the cameras at 511 keV. Certain simulation steps, such as the modelling of radionuclide decay times, scintillation photon transport and interactions with photomultipliers, as well as detector dead time corrections were included to make the modelling of the cameras more realistic than previous studies. The Si/LaBr3:Ce Compton camera shows superior efficiency of 2.0×10⁻³ and resolution of 5.3 mm over the Si/NaI(Tl) Compton camera model which has the efficiency of 1.6×10⁻³ and resolution of 6.9 mm at a source-to-scatterer distance of interest, 2.5 cm. A similar result sequence is obtained for two breast tumours of 5 mm diameter embedded in the medial region of an average-size breast phantom of thickness 5 cm. Notably, the signal-to-noise ratios (SNR) obtained for the Si/LaBr3:Ce camera are 9.7 and 3.4 for tumour/background radiation uptakes of 10:1 and 6:1, whereas 6.8 and 2.4 were obtained for the Si/NaI(Tl) camera model for the same tumour/background radiation uptakes respectively. It is therefore envisioned that with lower cost, LaBr3:Ce could replace NaI(Tl) as the Compton camera absorber.
  • Item type:Publication,
    AFOMP Policy Statement No. 3: recommendations for the education and training of medical physicists in AFOMP countries
    2011, Springer
    AFOMP recognizes that clinical medical physicists should demonstrate that they are competent to practice their profession by obtaining appropriate education, training and supervised experience in the specialties of medical physics in which they practice, as well as having a basic knowledge of other specialties. To help its member countries to achieve this, AFOMP has developed this policy to provide guidance when developing medical physicist education and training programs. The policy is compatible with the standards being promoted by the International Organization for Medical Physics and the International Medical Physics Certification Board.
  • Item type:Publication,
    The teaching, education and accreditation programs of the Australasian College of Physical Scientists and Engineers in Medicine
    2011, Abdus Salam International Centre for Theoretical Physics, ICTP
    Describes and evaluates the teaching, education and accreditation programs of the Australasian College of Physical Scientists and Engineers in Medicine.