<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

University of Waikato Research

Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288

Browse

Search Results

Now showing 1 - 10 of 53
  • Item type:Publication,
    A strategy for the correction of effects of jitter in AMCW lidar images
    2013, IEEE
    Full-field range imaging cameras, which are an example of amplitude modulated continuous wave (AMCW) lidar, are subject to multiple error sources. In this paper we consider the possibility that a global jitter and/or drift occurs between the modulation signals to the active illumination source and the camera sensor. A model for jitter is presented and is used to characterise the jitter in a real camera system. Correction of the effects of jitter in real acquired range images is demonstrated by a reduction of the standard deviation of random noise by up to a factor of five, with the best reductions occurring in pixels that receive a strong signal.
  • Item type:Publication,
    Simple harmonic error cancellation in time of flight range imaging
    2015, OAS Publishing
    Amplitude modulated continuous wave (AMCW) time of flight (ToF) range imaging provides a full field of distance measurement, but common hardware is implemented with digital technology which leads to unwanted harmonic content, a principle source of error in the distance measurements. Existing strategies for correction of harmonics require auxiliary measurements and amplify noise. A small modification of the data acquisition procedure is described which, intrinsically, is invariant to at least one harmonic. The third harmonic, the main cause of harmonic error, is targeted. Compared to traditional measurements the third harmonic is eliminated with no significant increase in noise variance observed.
  • Item type:Publication,
    Application of lidar techniques to time-of-flight range imaging
    2015, OPTICAL SOC AMER
    Amplitude modulated continuous wave (AMCW) time-of flight (ToF) range imaging cameras measure distance by illuminating the scene with amplitude modulated light and measuring the phase difference between the transmitted and reflected modulation envelope. This method of optical range measurement suffers from errors caused by multiple propagation paths, motion, phase wrapping and non-ideal amplitude modulation. In this paper a ToF camera is modified to operate in modes analogous to continuous wave (CW) and stepped frequency continuous wave (SFCW) lidar. In CW operation the velocity of objects can be measured. CW measurement of velocity was linear with true velocity (R² = 0.9969). Qualitative analysis of a complex scene confirms that range measured by SFCW is resilient to errors caused by multiple propagation paths, phase wrapping and non-ideal amplitude modulation which plague AMCW operation. In viewing a complicated scene through a translucent sheet, quantitative comparison of AMCW with SFCW demonstrated a reduction in the median error from −1.3 m to −0.06 m with inter-quartile range of error reduced from 4.0 m to 0.18 m.
  • Item type:Publication,
    Extracting the MESA SR4000 Calibrations
    2015, SPIE
    Time-of-flight range imaging cameras are capable of acquiring depth images of a scene. Some algorithms require these cameras to be run in `raw mode', where any calibrations from the off-the-shelf manufacturers are lost. The calibration of the MESA SR4000 is herein investigated, with an attempt to reconstruct the full calibration. Possession of the factory calibration enables calibrated data to be acquired and manipulated even in “raw mode.” This work is motivated by the problem of motion correction, in which the calibration must be separated into component parts to be applied at different stages in the algorithm. There are also other applications, in which multiple frequencies are required, such as multipath interference correction. The other frequencies can be calibrated in a similar way, using the factory calibration as a base. A novel technique for capturing the calibration data is described; a retro-reflector is used on a moving platform, which acts as a point source at a distance, resulting in planar waves on the sensor. A number of calibrations are retrieved from the camera, and are then modelled and compared to the factory calibration. When comparing the factory calibration to both the “raw mode” data, and the calibration described herein, a root mean squared error improvement of 51:3mm was seen, with a standard deviation improvement of 34:9mm. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
  • Item type:Publication,
    Resolving Multiple Propagation Paths in Time of Flight Range Cameras using Direct and Global Separation Methods
    2015, SPIE
    Time of flight (ToF) range cameras illuminate the scene with an amplitude-modulated continuous wave light source and measure the returning modulation envelopes: phase and amplitude. The phase change of the modulation envelope encodes the distance travelled. This technology suffers from measurement errors caused by multiple propagation paths from the light source to the receiving pixel. The multiple paths can be represented as the summation of a direct return, which is the return from the shortest path length, and a global return, which includes all other returns. We develop the use of a sinusoidal pattern from which a closed form solution for the direct and global returns can be computed in nine frames with the constraint that the global return is a spatially lower frequency than the illuminated pattern. In a demonstration on a scene constructed to have strong multipath interference, we find the direct return is not significantly different from the ground truth in 33∕136 pixels tested; where for the full-field measurement, it is significantly different for every pixel tested. The variance in the estimated direct phase and amplitude increases by a factor of eight compared with the standard time of flight range camera technique.
  • Item type:Publication,
    Analysis of the SoftKinetic DepthSense for Range Imaging
    2013, Springer
    We analyse the SoftKinetic DepthSense 325 range imaging camera for precision and accuracy in ranging out to 3 m. Flat planar targets (one a grey board, the other made from retroreflective material) are imaged at a variety of distances. Straight-forward image processing is used to identify the target and calculate the range and the root mean square variation in ranging to the target. It is found that inaccuracies in ranging of up to 2 cm occur to the grey board when imaging over 0 m to 1.5 m and the precision in ranging degrades from just below 1 cm at 0 m to almost 10 cm at 1.5 m. Similar inaccuracies occur with the retroreflective target but the precision is always under 1 cm even out to 3 m due to the strong signal return received from the target.
  • Item type:Publication,
    Closed-form inverses for the mixed pixel/multipath interference problem in AMCW lidar
    2012, SPIE
    We present two new closed-form methods for mixed pixel/multipath interference separation in AMCW lidar systems. The mixed pixel/multipath interference problem arises from the violation of a standard range-imaging assumption that each pixel integrates over only a single, discrete backscattering source. While a numerical inversion method has previously been proposed, no close-form inverses have previously been posited. The first new method models reflectivity as a Cauchy distribution over range and uses four measurements at different modulation frequencies to determine the amplitude, phase and reflectivity distribution of up to two component returns within each pixel. The second new method uses attenuation ratios to determine the amplitude and phase of up to two component returns within each pixel. The methods are tested on both simulated and real data and shown to produce a significant improvement in overall error. While this paper focusses on the AMCW mixed pixel/multipath interference problem, the algorithms contained herein have applicability to the reconstruction of a sparse one dimensional signal from an extremely limited number of discrete samples of its Fourier transform.
  • Item type:Publication,
    Verification of multi-view point-cloud registration for spherical harmonic cross-correlation
    2012, ACM
    Spherical harmonic cross-correlation is a robust registration algorithm that brings two point-clouds of the same scene into coarse rotational alignment. The found rotation however may not give the desired alignment, as misalignments can occur if there is not enough overlap between point-clouds, or if they contain a form of symmetry. We propose a verification method whose purpose is to determine if registration has failed for a priori unknown registration. The rotational transformation between multiple clouds must satisfy internal consistency, namely multiple rotational transformations are transitive. The rotation verification is performed using triplets of images, which are cross-referenced with each other to classify rotations individually. Testing is performed on a dataset of a priori known registrations. It is found that when the number of images or the percentage of correct rotations is increased, the number of correct rotation classifications improves. Even when tested with only four images and a correct rotation percentage of 17%, the rotation verification is still considered a viable method for classifying rotations. Spherical harmonic cross-correlation is benefited by rotation verification as it provides an additional approach for checking whether found rotations are correct.
  • Item type:Publication,
    Understanding and ameliorating non-linear phase and amplitude responses in AMCW Lidar
    2012, MDPI
    Amplitude modulated continuous wave (AMCW) lidar systems commonly suffer from non-linear phase and amplitude responses due to a number of known factors such as aliasing and multipath inteference. In order to produce useful range and intensity information it is necessary to remove these perturbations from the measurements. We review the known causes of non-linearity, namely aliasing, temporal variation in correlation waveform shape and mixed pixels/multipath inteference. We also introduce other sources of non-linearity, including crosstalk, modulation waveform envelope decay and non-circularly symmetric noise statistics, that have been ignored in the literature. An experimental study is conducted to evaluate techniques for mitigation of non-linearity, and it is found that harmonic cancellation provides a significant improvement in phase and amplitude linearity.
  • Item type:Publication,
    Analysis of ICP variants for the registration of partially overlapping time-of-flight range images
    2010, IEEE
    The iterative closest point (ICP) algorithm is one of the most commonly used methods for registering partially overlapping range images. Nevertheless, this algorithm was not originally designed for this task, and many variants have been proposed in an effort to improve its prociency. The relatively new full-field amplitude-modulated time-of-flight range imaging cameras present further complications to registration in the form of measurement errors due to mixed and scattered light. This paper investigates the effectiveness of the most common ICP variants applied to range image data acquired from full-field range imaging cameras. The original ICP algorithm combined with boundary rejection performed the same as or better than the majority of variants tested. In fact, many of these variants proved to decrease the registration alignment.