University of Waikato Research

Permanent URI for this communityhttps://researchcommons.waikato.ac.nz/handle/10289/10288

Browse

Search Results

Now showing 1 - 6 of 6
  • Item type:Publication,
    Monte Carlo evaluation of a Compton camera in breast and brain imaging
    2013, Springer
    Background: The Compton camera is increasingly becoming the subject of investigation for possible implementa- tion in nuclear medical imaging. It is likely to have advantages over Anger camera in medical imaging. However, very little has been done to characterize its performance for specific medical imaging techniques. There is therefore a need to fill in the gaps in knowledge relating to realistic evaluation of the viability of the camera for nuclear medical imaging. Objective: The present study has sought to explore the viability of a prototype Compton camera in breast and brain imaging. Methods: The GEANT4 simulation software was used to model the radiation transport and interactions with matter. Simulations were carried out of a Si/CZT Compton camera being used in breast and brain imaging. In order to study a challenging detection case, the volumes of two simulated breast tumours were chosen to be 0.65 mL, and embedded in the medial region of the breast. For the brain imaging, a multitracing approach was used, and imaging was done parallel to the orbitomeatal line of the brain. Results: The results suggest that the Compton camera would visualize small breast tumours of about 0.65 mL volume, placed at the medial region of an average compressed human breast. Although brain imaging using the Compton camera seems to be promising, analyses suggest however that beyond a distance difference of 2 cm between two brain tumours, there may be a need to rotate the camera around the human head for efficient brain imaging. Conclusions: It is envisioned that with further work, the Compton camera could replace the Anger camera in breast and brain imaging.
  • Item type:Publication,
    Evaluation of detector material and radiation source position on Compton camera’s ability for multitracer imaging
    2012, Springer
    We present a study on the effects of detector material, radionuclide source and source position on the Compton camera aimed at realistic characterization of the camera's performance in multitracer imaging as it relates to brain imaging. The GEANT4 Monte Carlo simulation software was used to model the physics of radiation transport and interactions with matter. Silicon (Si) and germanium (Ge) detectors were evaluated for the scatterer, and cadmium zinc telluride (CZT) and cerium-doped lanthanum bromide (LaBr3:Ce) were considered for the absorber. Image quality analyses suggest that the use of Si as the scatterer and CZT as the absorber would be preferred. Nevertheless, two simulated Compton camera models (Si/CZT and Si/LaBr3:Ce Compton cameras) that are considered in this study demonstrated good capabilities for multitracer imaging in that four radiotracers within the nuclear medicine energy range are clearly visualized by the cameras. It is found however that beyond a range difference of about 2 cm for In-113m and F-18 radiotracers in a brain phantom, there may be a need to rotate the Compton camera for efficient brain imaging.
  • Item type:Publication,
    Evaluation of two Compton camera models for scintimammography
    2011, Elsevier
    We study the performance of a Si/LaBr3:Ce Compton camera model for scintimammography, and compare it with a Si/NaI(Tl) model of similar geometry. The GEANT4 simulation toolkit was used to study the behaviour of the cameras at 511 keV. Certain simulation steps, such as the modelling of radionuclide decay times, scintillation photon transport and interactions with photomultipliers, as well as detector dead time corrections were included to make the modelling of the cameras more realistic than previous studies. The Si/LaBr3:Ce Compton camera shows superior efficiency of 2.0×10⁻³ and resolution of 5.3 mm over the Si/NaI(Tl) Compton camera model which has the efficiency of 1.6×10⁻³ and resolution of 6.9 mm at a source-to-scatterer distance of interest, 2.5 cm. A similar result sequence is obtained for two breast tumours of 5 mm diameter embedded in the medial region of an average-size breast phantom of thickness 5 cm. Notably, the signal-to-noise ratios (SNR) obtained for the Si/LaBr3:Ce camera are 9.7 and 3.4 for tumour/background radiation uptakes of 10:1 and 6:1, whereas 6.8 and 2.4 were obtained for the Si/NaI(Tl) camera model for the same tumour/background radiation uptakes respectively. It is therefore envisioned that with lower cost, LaBr3:Ce could replace NaI(Tl) as the Compton camera absorber.
  • Item type:Publication,
    A Monte Carlo evaluation of three Compton camera absorbers
    2011, Springer
    We present a quantitative study on the performance of cadmium zinc telluride (CZT), thallium-doped sodium iodide (NaI(Tl)) and germanium (Ge) detectors as potential Compton camera absorbers. The GEANT4 toolkit was used to model the performance of these materials over the nuclear medicine energy range. CZT and Ge demonstrate the highest and lowest efficiencies respectively. Although the best spatial resolution was attained for Ge, its lowest ratio of single photoelectric to multiple interactions suggests that it is most prone to inter-pixel cross-talk. In contrast, CZT, which demonstrates the least positioning error due to multiple interactions, has a comparable spatial resolution with Ge. Therefore, we modelled a Compton camera system based on silicon (Si) and CZT as the scatterer and absorber respectively. The effects of the detector parameters of our proposed system on image resolution were evaluated and our results show good agreement with previous studies. Interestingly, spatial resolution which accounted for the least image degradation at 140.5 keV became the dominant degrading factor at 511 keV, indicating that the absorber parameters play some key roles at higher energies. The results of this study have validated the predictions by An et al. which state that the use of a higher energy gamma source together with reduction of the absorber segmentation to sub-millimetre could achieve the image resolution of 5 mm required in medical imaging.
  • Item type:Publication,
    GEANT4 simulation of the effects of Doppler energy broadening in Compton imaging
    2011, Springer
    A Monte Carlo approach was used to study the effects of Doppler energy broadening on Compton camera performance. The GEANT4 simulation toolkit was used to model the radiation transport and interactions with matter in a simulated Compton camera. The low energy electromagnetic physics model of GEANT4 incorporating Doppler broadening developed by Longo et al. was used in the simulations. The camera had a 9 × 9 cm scatterer and a 10 × 10 cm absorber with a scatterer to-absorber separation of 5 cm. Modelling was done such that only the effects of Doppler broadening were taken into consideration and effects of scatterer and absorber thickness and pixelation were not taken into account, thus a ‘perfect’ Compton camera was assumed. Scatterer materials were either silicon or germanium and the absorber material was cadmium zinc telluride. Simulations were done for point sources 10 cm in front of the scatterer. The results of the simulations validated the use of the low energy model of GEANT4. As expected, Doppler broadening was found to degrade the Compton camera imaging resolution. For a 140.5 keV source the resulting full-width-at-half-maximum (FWHM) of the point source image without accounting for Doppler broadening and using a silicon scatterer was 0.58 mm. This degraded to 7.1 mm when Doppler broadening was introduced and degraded further to 12.3 mm when a germanium scatterer was used instead of silicon. But for a 511 keV source, the FWHM was better than for a 140 keV source. The FWHM improved to 2.4 mm for a silicon scatterer and 4.6 mm for a germanium scatterer. Our result for silicon at 140.5 keV is in very good agreement with that published by An et al.
  • Item type:Publication,
    Effects of energy threshold and dead time on Compton camera performance
    2011, Elsevier BV
    We study the effects of energy threshold and dead time on the sensitivity and image resolution of the Compton camera. The simulation model includes the decay times, detection time jitters, energy threshold and detector dead time as well as basic detector parameters such as Doppler broadening, energy resolution and finite detector resolution. The GEANT4 toolkit was used to model the camera geometry and performance for two common nuclear medicine energies that correspond to 99mTc (140.5 keV) and ¹⁸F (511 keV) radiotracers. Results without the energy threshold and time effects show good agreement with previous studies. For 140.5 keV, the inclusion of energy threshold improved image resolution from 10.7 to 9.5 mm with a source-to-detector distance of 5 cm, while the inclusion of time effects made no further difference on resolution. The energy threshold reduced the sensitivity by 48%, and subsequent inclusion of time effects further reduced the sensitivity by 17%. At 511 keV, the application of energy threshold reduced the sensitivity by 6%, while the time effects dominated count rate losses with further reduction of 13%. However, the inclusion of the two effects had negligible impact on the resolution.