    Supercapacitor assisted multilevel inverter topology for off-grid renewable energy systems
    2024, IEEE
    Supercapacitor assisted (SCA) techniques are a new family of power electronic building blocks for renewable energy systems based on the theory published as SCA-loss management (SCALoM) concept. SCA inverter is a unique application of SCALoM theory, capable of meeting any capacity of off-grid inverter requirement, based on a combination of an even number of smaller inverters with suitably sized supercapacitor banks. SCA-inverter technique reduces input loop losses and transistor voltage stresses while providing DC-UPS capability without using batteries. This paper discusses the technical background of the SCA-inverter arrangement of operating seamlessly without common load balancing issues observed in other multi-inverter systems and techniques. The experiment results of two/four-SCA-inverter arrangement show stable operation of the inverter systems, both in switching transients of the supercapacitor banks and steady state operation. Four-SCA-inverter arrangement shows up to 2.5% efficiency improvement by equally partitioning the load into four inverters with no load balancing issues. As the four supercapacitor modules are switched at millihertz order frequency, it eliminaties the need for any EMC filters and dynamic losses in the frontend SCA arrangement are negligible.
  • Item type:Publication,
    Implementation of a supercapacitor assisted inverter system for reducing input loop losses: Preliminary results of a four-stage inverter
    2024, IEEE
    Supercapacitor assisted loss management (SCALoM) concept has laid the theoretical foundation to develop high efficiency power converters for renewable energy systems using supercapacitors as lossless voltage droppers and energy buffers. SCALoM theory is applicable to inverter combinations in reducing overall losses, mainly occurring in the input loop, including losses in the DC bus capacitor. Supercapacitor assisted (SCA) multi-inverter technique reduces the voltage stress on the internal components of inverters enabling the use of more efficient lower voltage rated components. A summary of the theoretical foundations with reference to previous works on the topic is presented first. The four-SCA-inverter technique discussed in this paper extends the input voltage range of an inverter system by two times and reduces the input loop current by two times. The preliminary results obtained from the first experimental prototype of the 700W four-SCA-inverter system coupled with four identical 250F supercapacitor modules switched at low frequencies (less than 0.02 Hz), show up to 2.53% of efficiency gain at the inverter end. Additionally, proposed technique provides unquantified efficiency gains by reducing the ripple currents in the system, functioning as an energy buffer. Development of a high power capable SCA-inverter prototype is in progress.
  • Item type:Publication,
    A supercapacitor assisted technique for reducing losses in the input loop of an inverter system for solar PV applications
    2024, IEEE
    This paper presents a method of using supercapacitor modules in the input loop, to reduce the input losses of a typical inverter system used in solar applications. It is an extension of the supercapacitor-assisted loss management principle (SCALoM), where supercapacitors act as lossless droppers and energy buffers at the input end with a very low frequency switching scheme with reduced dynamic losses in switches compared to switched capacitor-inverter systems. The technique uses a set of micro-inverters, with the same total power capability as a single inverter, combined with a set of supercapacitor banks switching at a low frequency to reduce the voltage stress and rms current through the H-bridge input stages of the inverters, enhancing the end-to-end efficiency of the overall system. The proposed technique does not require a re-design of the commercially available inverters and adds DC-UPS capability to the system. Preliminary experimental results of the SCA(super capacitor assisted) two-inverter arrangement show stable transient and steady state operations, and the system is up to 2.2% efficient compared to a single central inverter arrangement. With the proposed SCA four-inverter configuration, inverter's overall power load can be further partitioned, and according to the analytical study further improvements in the overall efficiency can be achieved over the SCA two-inverter arrangement.
  • Item type:Publication,
    Preliminary experiments quantifying the arcing process in a DC circuit breaker development project
    2024, Institute of Electrical and Electronics Engineers
    AC circuit breakers are well-established technology today. However, DC circuit breakers (DCCB) are not easy to design and build since there are no zero crossings in a DC power supply. Mechanical and semiconductor switches are the key elements considered under various circuit topologies to design DCCBs. However, mass-produced commercial DCCBs are designed by modifying AC breakers by connecting multiple poles in series and/or using permanent magnets inside the breaker to lower the cost of DCCBs except for special applications such as in the military industry. Some of the major issues behind the DCCB design are fundamentally explained in this research with simple experimental results based on DC arc characteristics. We intend using these experimental observations in a new design approach for DC circuit breakers using supercapacitor energy absorption.
  • Item type:Publication,
    A low frequency supercapacitor circulation technique to improve the efficiency of linear regulators based on LDO ICs
    2011, IEEE
    Linear regulators have output specifications far superior to switch-mode techniques, except for the overall efficiency. This efficiency limitation can be overcome by applying a very low frequency supercapacitor circulation technique at the input side of a low dropout regulator IC. The technique was proven in 12V to 5 V versions, and, can be easily applied to other power supplies such as 5 to 3.3V or 5 to 1.5V versions required by various processors. The paper outlines the concepts and experimental results related to this technique. With the commercial LDO chips available with output current ratings up to 10A, and, thin profile supercapacitors available are with DC voltage ratings from 2.3V to 5.5V, the technique assists developing medium current linear regulators which could compete with present day switch-mode power supplies in efficiency and compactness, maintaining the superior output specifications of a linear regulator.