<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

Design of a novel mechatronic fatigue testing system to test the functional lifespan of a compliant mechanism kiwifruit gripper-end effector device

dc.contributor.authorBaldo, Paulo
dc.contributor.authorMcGuinness, Benjamin
dc.contributor.authorVenter, Christoff
dc.contributor.authorPrinz, Eva
dc.contributor.authorLe, Hung Phan
dc.contributor.authorDuke, Mike
dc.contributor.authorSingh, Ajit Pal
dc.coverage.spatialConference held at Edith Cowan University, Perth, Australia
dc.date.accessioned2026-08-18T23:24:57Z
dc.date.available2026-08-18T23:24:57Z
dc.date.issued2025
dc.description.abstractThere is limited research into the fatigue life of compliant mechanisms, and a lack of standardized equipment to fatigue test such structures. This paper presented PneuGrip 2, a novel mechatronic fatigue testing system designed to fatigue test compliant mechanism robotic kiwifruit grippers. The design of its interacting mechanical, electronic, and control systems arc outlined. A compliant gripper is fatigue tested for one million cycles, replicating the forces experienced in a typical harvesting motion. The compliant mechanism showed no degradation in performance after the test. While the study demonstrated a promising lifetime for the gripper, further testing is required to establish statistical significance and fully quantify its service life.
dc.identifier.citationBaldo, P., McGuinness, B., Venter, C., Prinz, E., Le, H. P., Duke, M., & Singh, A. P. (2025). Design of a novel mechatronic fatigue testing system to test the functional lifespan of a compliant mechanism kiwifruit gripper-end effector device. Australasian Conference on Robotics and Automation, ACRA.
dc.identifier.issn1448-2053
dc.identifier.urihttps://hdl.handle.net/10289/18552
dc.language.isoen
dc.publisherACRA
dc.relation.isPartOfACRA 2025 Proceedings
dc.rightsThis is a conference presentation from the proceedings of the Australasian Conference on Robotics and Automation (ACRA 2025). © 2025 The authors.
dc.sourceAustralasian Conference on Robotics and Automation (ACRA 2025)
dc.titleDesign of a novel mechatronic fatigue testing system to test the functional lifespan of a compliant mechanism kiwifruit gripper-end effector device
dc.typeConference Contribution
dspace.entity.typePublication
pubs.publisher-urlhttps://ssl.linklings.net/conferences/acra/acra2025_proceedings/views/includes/files/pap170s2.pdf